āļ āļēāļĐāļēāđ„āļ—āļĒ

Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture

āļ„āļļāļ“āļĨāļąāļāļĐāļ“āļ°āļŠāļģāļ„āļąāļ

Equipped with new functionality

  • Now compatible with Fluke Connect mobile app and all Fluke FC enabled test tools with optional ir3000 FC infrared connector (sold separately).
  • Let your team see what you see in an instant with ShareLiveâ„Ē video call (requires Fluke Connect mobile app and ir3000 FC wireless connector).
  • TrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred.
  • Limited lifetime warranty.

āļ āļēāļžāļĢāļ§āļĄāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒ: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture

Fluke ConnectÂŪ

Learn more about Fluke Connect

Now compatible with Fluke ConnectÂŪ Mobile App
The Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before.

āļ‚āđ‰āļ­āļĄāļđāļĨāļˆāļģāđ€āļžāļēāļ°: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture

Specifications
Function
DC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.025%
AC voltsRange / resolution50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V
Basic accuracy0.4% (True-RMS)
DC currentRange / resolution500.00 ΞA, 5000.0 ΞA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.05%
AC currentRange / resolution500.00 ΞA, 5000.0 ΞA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A
Basic accuracy0.6% (True-RMS)
Temperature (excluding probe)Range / resolution-200.0°C to 1350.0°C (-328.0°F to 2462.0°F)
Basic accuracy1.0%
ResistanceRange / resolution500.00 ÎĐ, 5.0000 kÎĐ, 50.000 kÎĐ, 500.00 kÎĐ, 5.0000 MÎĐ, 50.00 MÎĐ, 500.0 MÎĐ
Basic accuracy0.05%
CapacitanceRange / resolution1.000 n, 10.00 nF, 100.0 nF, 1.000 ΞF, 10.00 ΞF, 100.0 ΞF, 1000 ΞF, 10.00 mF, 100 mF
Basic accuracy1.0%
FrequencyRange / resolution99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz
Basic accuracy0.005%
ConnectivityOptional infrared connector via Fluke ir3000 FC
General Specifications
Maximum voltage between any terminal and earth ground1000 V
Battery type6 AA alkaline batteries, IECLR6
Battery life100 hours minimum, 200 hours in logging mode
TemperatureOperating-20°C to 55°C
Storage-40°C to 60°C
Relative humidity0 to 90% (0 t 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C)
Electromagnetic compatibilityEMC EN61326–1
VibrationRandom vibration per MIL-PRF-28800F Class 2
Shock1 meter drop per IEC/EN 61010–1 3rd Edition
Size (H x W x L)22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in)
Weight870.9 g (28 oz)
Multiple on screen displaysYes
True-RMS AC bandwidth100 kHz
dBV/dBmYes
DC mV resolution1 ΞV
Megohm rangeUp to 500 MÎĐ
Conductance50.00 nS
Continuity beeperYes
Battery/fuse accessYes/Yes
Elapse time clockYes
Time of day clockYes
Min-max-avgYes
Peak250 Ξs
Duty cycle0.01% to 99.99%
Pulse width0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms
HoldYes
Isolated optical interfaceYes
Auto/touch holdYes
Reading memoryYes
Log to PCYes
Interval/event loggingYes
Logging memoryUp to 10,000 readings
Wireless connectivity (optional)Yes

āļĢāļļāđˆāļ™: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture

Fluke 287
Fluke 287 True-RMS Electronics Logging Multimeter
āļ‹āļ·āđ‰āļ­āđ€āļĨāļĒ

Includes:

  • Fluke 287 True-RMS Electronics Logging Multimeter
  • TL71 Test Leads
  • AC175 Alligator Clips
  • Batteries – 6 AA Installed

Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication