Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture
āļāļļāļāļĨāļąāļāļĐāļāļ°āļŠāļģāļāļąāļ
Equipped with new functionality
- Now compatible with Fluke Connect mobile app and all Fluke FC enabled test tools with optional ir3000 FC infrared connector (sold separately).
- Let your team see what you see in an instant with ShareLiveâĒ video call (requires Fluke Connect mobile app and ir3000 FC wireless connector).
- TrendCapture quickly graphically displays logged data session to quickly determine whether anomalies may have occurred.
- Limited lifetime warranty.
āļāļēāļ§āļāđāđāļŦāļĨāļāļāļđāđāļĄāļ·āļāļāļĨāļīāļāļ āļąāļāļāđ āļāļēāļ§āļāđāđāļŦāļĨāļāđāļāđāļāļāđāļāļĄāļđāļĨāļāļĨāļīāļāļ āļąāļāļāđ
āļ āļēāļāļĢāļ§āļĄāļāļĨāļīāļāļ āļąāļāļāđ: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture
Learn more about Fluke Connect
Now compatible with Fluke ConnectÂŪ Mobile App
The Fluke 287 True-RMS Electronics Logging Multimeter with TrendCapture quickly documents design performance and graphically displays what happened. Its unique logging and graphing capabilities mean you no longer need to download logged readings to a PC to detect a trend. The Fluke 287 packs more accuracy and convenience into a handheld multimeter than ever before.
āļāđāļāļĄāļđāļĨāļāļģāđāļāļēāļ°: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture
Specifications | ||
Function | ||
DC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.025% | |
AC volts | Range / resolution | 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V |
Basic accuracy | 0.4% (True-RMS) | |
DC current | Range / resolution | 500.00 ΞA, 5000.0 ΞA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.05% | |
AC current | Range / resolution | 500.00 ΞA, 5000.0 ΞA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A |
Basic accuracy | 0.6% (True-RMS) | |
Temperature (excluding probe) | Range / resolution | -200.0°C to 1350.0°C (-328.0°F to 2462.0°F) |
Basic accuracy | 1.0% | |
Resistance | Range / resolution | 500.00 ÎĐ, 5.0000 kÎĐ, 50.000 kÎĐ, 500.00 kÎĐ, 5.0000 MÎĐ, 50.00 MÎĐ, 500.0 MÎĐ |
Basic accuracy | 0.05% | |
Capacitance | Range / resolution | 1.000 n, 10.00 nF, 100.0 nF, 1.000 ΞF, 10.00 ΞF, 100.0 ΞF, 1000 ΞF, 10.00 mF, 100 mF |
Basic accuracy | 1.0% | |
Frequency | Range / resolution | 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz |
Basic accuracy | 0.005% | |
Connectivity | Optional infrared connector via Fluke ir3000 FC | |
General Specifications | ||
Maximum voltage between any terminal and earth ground | 1000 V | |
Battery type | 6 AA alkaline batteries, IECLR6 | |
Battery life | 100 hours minimum, 200 hours in logging mode | |
Temperature | Operating | -20°C to 55°C |
Storage | -40°C to 60°C | |
Relative humidity | 0 to 90% (0 t 37°C), 0 to 65% (37°C to 45°C), 0 to 45% (45°C to 55°C) | |
Electromagnetic compatibility | EMC EN61326â1 | |
Vibration | Random vibration per MIL-PRF-28800F Class 2 | |
Shock | 1 meter drop per IEC/EN 61010â1 3rd Edition | |
Size (H x W x L) | 22.2 x 10.2 x 6 cm (8.75 x 4.03 x 2.38 in) | |
Weight | 870.9 g (28 oz) | |
Multiple on screen displays | Yes | |
True-RMS AC bandwidth | 100 kHz | |
dBV/dBm | Yes | |
DC mV resolution | 1 ΞV | |
Megohm range | Up to 500 MÎĐ | |
Conductance | 50.00 nS | |
Continuity beeper | Yes | |
Battery/fuse access | Yes/Yes | |
Elapse time clock | Yes | |
Time of day clock | Yes | |
Min-max-avg | Yes | |
Peak | 250 Ξs | |
Duty cycle | 0.01% to 99.99% | |
Pulse width | 0.025 ms, 0.25 ms, 2.5 ms, 1250.0 ms | |
Hold | Yes | |
Isolated optical interface | Yes | |
Auto/touch hold | Yes | |
Reading memory | Yes | |
Log to PC | Yes | |
Interval/event logging | Yes | |
Logging memory | Up to 10,000 readings | |
Wireless connectivity (optional) | Yes |
āļĢāļļāđāļ: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture
Fluke 287
Fluke 287 True-RMS Electronics Logging Multimeter
Includes:
- Fluke 287 True-RMS Electronics Logging Multimeter
- TL71 Test Leads
- AC175 Alligator Clips
- Batteries â 6 AA Installed
Requires Fluke ir3000 FC Infrared Connector for Fluke Connect communication
āļāļđāđāļĄāļ·āļāđāļĨāļ°āđāļŦāļĨāđāļāļāđāļāļĄāļđāļĨ: Fluke 287 True-rms Electronics Logging Multimeter with TrendCapture
- 287/289 | āļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 287/289 | āļāđāļāļĄāļđāļĨāđāļŠāļĢāļīāļĄāļāļđāđāļĄāļ·āļāļāļđāđāđāļāđ
- 287/289 | āļāļĢāļ°āļāļēāļĻāđāļāļĩāđāļĒāļ§āļāļąāļāļāļ§āļēāļĄāđāļāļĢāļāļąāļāļāļāļāļŦāļāđāļ§āļĒāļāļ§āļēāļĄāļāļģ
- 287/289 | āļāļđāđāļĄāļ·āļāļāđāļēāļāļāļīāļāđāļāļāļĒāđāļ
- 287/289 | āļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- 287/289 | āļāđāļāļĄāļđāļĨāđāļŠāļĢāļīāļĄāļāļđāđāļĄāļ·āļāļāļēāļĢāļŠāļāļāđāļāļĩāļĒāļ
- 287/289 | āđāļāļāļŠāļēāļĢāđāļāļ·āđāļāļāļ§āļēāļĄāļāļĨāļāļāļ āļąāļĒ
- 287/289 | āļāđāļāļĄāļđāļĨāđāļŠāļĢāļīāļĄāđāļāļāļŠāļēāļĢāđāļāļ·āđāļāļāļ§āļēāļĄāļāļĨāļāļāļ āļąāļĒ
- Connecting a thermal imager to your iPhone
- Connecting multiple tools at the same time with Fluke ConnectÂŪ
- Connecting the T3000 FC with the Fluke ConnectâĒ app
- How to create an equipment baseline with EquipmentLogâĒ history
- How to email a measurement using the Fluke Connect app
- How to record measurements and graphs
- How to save measurements to EquipmentLogâĒ history
- How to share measurements on equipment using the Fluke ConnectâĒ app
- Identifying intermittent conditions with TrendItâĒ graphs
- Introduction to 789FC
- Measurement history in one place using EquipmentLogâĒ history
- Measuring from a safe distance using the Fluke ConnectâĒ app
- Performing predictive maintenance with Fluke ConnectâĒ
- Saving measurements with AutoRecordâĒ measurements
- Share equipment health with EquipmentLogâĒ history
- Using ShareLiveâĒ video call to share live measurements and video
- Viewing and graphing three phase measurements