Fluke 375 FC True-rms AC/DC Clamp Meter

Model#: Fluke 375 FC
  • Fluke 375 FC True-rms AC/DC Clamp Meter
  • Fluke 375 FC True-rms AC/DC Clamp Meter
  • Fluke 375 FC True-rms AC/DC Clamp Meter
  • Fluke 375 FC True-rms AC/DC Clamp Meter

āļ„āļļāļ“āļĨāļąāļāļĐāļ“āļ°āļŠāļģāļ„āļąāļ

  • High performance clamp meter that measures very low voltage and high resistance
  • Transmits measurements to your smartphone via Fluke ConnectÂŪ so you can view them at a safer distance
  • Measures AC and DC current to 600 A, and AC and DC voltage to 1000 V
  • Measures AC current to 2500 A AC with optional iFlex flexible current probe

āļ āļēāļžāļĢāļ§āļĄāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒ: Fluke 375 FC True-rms AC/DC Clamp Meter

Fluke 375 FC True-RMS AC/CD Clamp Meter measures very low voltage and very high resistance

The Fluke 375 FC, part of the Fluke Connect family of wireless test tools, delivers high performance features and ease of use. It features a VFD low-pass filter for accurate motor drive measurements and wireless communications to transmit results to a smartphone via Fluke Connect

The 375 FC offers most of the features of the Fluke 376 FC including compatibility with the iFlex flexible current probe but, unlike the 376 FC, it does not include the iFlexÂŪ probe in the package. You can measure AC and DC current to 600 A and voltage up to 1000 V with the fixed jaw clamp. Or connect an optional iFlexÂŪ flexible current probe to expand your measurement range to 2500 A AC. The large diameter and flexible design of the iFlex probe make it easier to measure around large conductors in tight spaces or to access individual wires.

Wireless connectivity improves productivity

Using its Bluetooth connectivity to Apple and Android devices, you can read the 375 FC results a safe distance away on your smartphone, wearing less PPE. You can create and send reports in email right from the field and save results to the cloud. You can also converse with colleagues in real-time with ShareLiveâ„Ē video calls.

Versatile performance

With True-RMS AC voltage and current measurements, the 375 enables you to accurately troubleshoot non-linear signals. And you can log and trend measurements to pinpoint intermittents while you are performing other tasks. The Fluke 375 FC Clamp Meter is the direct replacement for the Fluke 375 Clamp Meter.

Other useful capabilities:

  • Compatible with optional TPAK magnetic hanging strap
  • Comes with batteries, soft carrying case, and three-year warranty
  • Features CAT III 1000 V, CAT IV 600 V safety rating
  • Measures capacitance to 1000 ÂĩF
  • Includes True-RMS voltage and current measurements to accurately measure non-linear signals
  • Measures frequency to 500 Hz and resistance to 60 kâ„Ķ with continuity detection
  • Includes Min/Max/Avg and inrush recording to capture variations automatically
  • Offers 500 mV DC measurement range to interface with other accessories
  • Runs on two AA alkaline batteries

āļ‚āđ‰āļ­āļĄāļđāļĨāļˆāļģāđ€āļžāļēāļ°: Fluke 375 FC True-rms AC/DC Clamp Meter

General Specifications
AC Current via Jaw
Range600.0 A
Resolution 0.1 A
Accuracy 2% ¹5 digits (10 Hz to 100 Hz)
2.5% Âą5 digits (100-500 Hz)
Crest Factor (50 Hz/60 Hz)3 @ 500 A
2.5 @ 600 A
Add 2% for C.F. >2
AC Current via Flexible Current Probe
Range2500 A
Resolution0.1 A (â‰Ī 600 A)
1 A (â‰Ī 2500 A)
Accuracy3% ±5 digits (5 – 500 Hz)
Crest Factor (50/60Hz)3.0 at 1100 A
2.5 at 1400 A
1.42 at 2500 A
Add 2% for C.F. > 2
Position Sensitivity
Flexible current probe
 i2500-10 Flexi2500-18 Flex
A  
Distance from Optimum0.5 in (12.7 mm)1.4 in (35.6 mm)
ErrorÂą0.5 %Âą0.5 %
B  
Distance from Optimum0.8 in (20.3 mm)2.0 in (50.8 mm)
ErrorÂą1.0 %Âą1.0 %
C  
Distance from Optimum1.4 in (35.6 mm)2.5 in (63.5 mm)
ErrorÂą2.0 %Âą2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC Current
Range600.0 A
Resolution0.1 A
Accuracy2% Âą5 digits
AC Voltage
Range1000 V
Resolution0.1 V (â‰Ī600.0 V)
1 V (â‰Ī1000 V)
Accuracy1.5% Âą5 digits (20 Hz to 500 Hz)
DC Voltage
Range1000 V
Resolution0.1 V (â‰Ī600.0 V)
1 V (â‰Ī1000 V)
Accuracy1% Âą5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1% Âą5 digits
Frequency via Jaw
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ¹5 digits
Trigger level 5 Hz to 10 Hz, â‰Ĩ10 A
10 Hz to 100 Hz, â‰Ĩ5 A
Frequency via Flexible Current Probe
Range5.0 Hz to 500.0 Hz
Resolution 0.1 Hz
Accuracy 0.5% ¹5 digits
Trigger level 5 Hz to 20 Hz, â‰Ĩ25 A
20 Hz to 100 Hz, â‰Ĩ20 A
100 Hz to 500 Hz, â‰Ĩ25 A
Resistance
Range60 kÎĐ
Resolution0.1 ÎĐ (â‰Ī600 ÎĐ)
1 ÎĐ (â‰Ī6000 ÎĐ)
10 ÎĐ (â‰Ī60 kÎĐ)
Accuracy1% Âą5 digits
Capacitance
Range1000 ΞF
Resolution0.1 ΞF (â‰Ī 100 ΞF)
1 Ξ F (â‰Ī 1000 ΞF)
Accuracy1% Âą4 digits
Mechanical Specifications
Maximum voltage between any terminal and earth ground1000 V
Batteries2 AA, NEDA 15A, IEC LR6
Operating temperature-10 °C to +50 °C
Storage temperature-40 °C to +60 °C
Operating humidity -
non-condensing (< 10°C)
â‰Ī90% RH (at 10 °C to 30 °C)
â‰Ī75% RH (at 30 °C to 40 °C)
Operating altitude3000 m
Storage altitude12,000 m
Size (L x W x H)249 x 85 x 45 mm
Weight395 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length
(head to electronics connector)
1.8 m
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IP ratingIEC 60529: IP30, non-operating
Radio Frequency Certification FCC IDT68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

āļĢāļļāđˆāļ™: Fluke 375 FC True-rms AC/DC Clamp Meter

Fluke 375 FC

Fluke 375 FC True-rms AC/DC Clamp Meter


āļ‹āļ·āđ‰āļ­āđ€āļĨāļĒ

Includes:

  • Soft carrying case
  • TL75 test leads
  • Two AA Alkaline batteries
  • Coated instruction card
  • Safety information sheet

Fluke Connect āļ­āļēāļˆāđ„āļĄāđˆāļĄāļĩāđƒāļŦāđ‰āļšāļĢāļīāļāļēāļĢāđƒāļ™āļšāļēāļ‡āļ›āļĢāļ°āđ€āļ—āļĻ

*āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļĄāļ·āļ­āļšāļēāļ‡āļĢāļļāđˆāļ™āļŠāļēāļĄāļēāļĢāļ–āđƒāļŠāđ‰āđ„āļ”āđ‰āđƒāļ™āļšāļēāļ‡āļ›āļĢāļ°āđ€āļ—āļĻ āđ‚āļ›āļĢāļ”āļ•āļĢāļ§āļˆāļŠāļ­āļšāļāļąāļšāļ•āļąāļ§āđāļ—āļ™āļˆāļģāļŦāļ™āđˆāļēāļĒāļ‚āļ­āļ‡ Fluke āļ—āļĩāđˆāļ­āļĒāļđāđˆāđƒāļāļĨāđ‰āļšāđ‰āļēāļ™

ÂĐ Fluke Corporation āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļŦāļĄāļēāļĒāļāļēāļĢāļ„āđ‰āļēāļ—āļąāđ‰āļ‡āļŦāļĄāļ”āđ€āļ›āđ‡āļ™āļāļĢāļĢāļĄāļŠāļīāļ—āļ˜āļīāđŒāļ‚āļ­āļ‡āļœāļđāđ‰āļ—āļĩāđˆāđ€āļ›āđ‡āļ™āđ€āļˆāđ‰āļēāļ‚āļ­āļ‡ āļāļēāļĢāđƒāļŦāđ‰āļšāļĢāļīāļāļēāļĢāđ„āļĢāđ‰āļŠāļēāļĒāđāļĨāļ°āļ‚āđ‰āļ­āļĄāļđāļĨāļœāđˆāļēāļ™āļŠāļĄāļēāļĢāđŒāļ—āđ‚āļŸāļ™āđ„āļĄāđˆāļĢāļ§āļĄāļ­āļĒāļđāđˆāđƒāļ™āļāļēāļĢāļŠāļąāđˆāļ‡āļ‹āļ·āđ‰āļ­ āļžāļ·āđ‰āļ™āļ—āļĩāđˆāđ€āļāđ‡āļšāļ‚āđ‰āļ­āļĄāļđāļĨ 5 GB āđāļĢāļāđƒāļŦāđ‰āļšāļĢāļīāļāļēāļĢāļŸāļĢāļĩ āđ€āļ‚āđ‰āļēāļāļąāļ™āđ„āļ”āđ‰āļāļąāļš iPhone 4s āļ‚āļķāđ‰āļ™āđ„āļ›āļ—āļĩāđˆāđƒāļŠāđ‰āļĢāļ°āļšāļšāļ›āļāļīāļšāļąāļ•āļīāļāļēāļĢ iOS 8 āļŦāļĢāļ·āļ­āļŠāļđāļ‡āļāļ§āđˆāļē; iPad (āđƒāļ™āļāļĢāļ­āļš iPhone āļšāļ™ iPad); Samsung Galaxy S4 āļ—āļĩāđˆāđƒāļŠāđ‰āļĢāļ°āļšāļšāļ›āļāļīāļšāļąāļ•āļīāļāļēāļĢ Android 4.3.x āļŦāļĢāļ·āļ­āļŠāļđāļ‡āļāļ§āđˆāļē āđāļĨāļ° Samsung Galaxy S, Nexus 5, HTC One āđāļĨāļ° HTC One M8 āļ—āļĩāđˆāđƒāļŠāđ‰āļĢāļ°āļšāļšāļ›āļāļīāļšāļąāļ•āļīāļāļēāļĢ Androidâ„Ē 4.4.x āļŦāļĢāļ·āļ­āļŠāļđāļ‡āļāļ§āđˆāļē Apple āđāļĨāļ°āđ‚āļĨāđ‚āļāđ‰ Apple āđ€āļ›āđ‡āļ™āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļŦāļĄāļēāļĒāļāļēāļĢāļ„āđ‰āļēāļ‚āļ­āļ‡ of Apple Inc. āļ—āļĩāđˆāļˆāļ”āļ—āļ°āđ€āļšāļĩāļĒāļ™āđƒāļ™āļŠāļŦāļĢāļąāļāļ­āđ€āļĄāļĢāļīāļāļēāđāļĨāļ°āļ›āļĢāļ°āđ€āļ—āļĻāļ­āļ·āđˆāļ™āđ† App Store āđ€āļ›āđ‡āļ™āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļŦāļĄāļēāļĒāļšāļĢāļīāļāļēāļĢāļ‚āļ­āļ‡ Apple Inc. āđāļĨāļ° Google Play āđ€āļ›āđ‡āļ™āđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļŦāļĄāļēāļĒāļāļēāļĢāļ„āđ‰āļēāļ‚āļ­āļ‡ Google Inc.

āđāļŠāļ—āļāļąāļšāļœāļđāđ‰āļŠāđˆāļ§āļĒ Fluke āļ‚āļ­āļ‡āđ€āļĢāļē
āļĨāđ‰āļēāļ‡āđāļŠāļ—