Industrial Temperature Calibrator Selection Guide
PPC4_Main_Display_sm.jpg
A temperature calibrator, often called a thermometer calibrator, is used to remove inaccuracies in installed thermometers and temperature sensors, because temperature measurement is a critical parameter in many industrial processes. Although simulators are sometimes called temperature calibrators or thermometer calibrators and may be used to provide calibration for the electronics in an installed system, a temperature source with a calibrated reference sensor is still required to provide a complete and meaningful calibration. Fluke Calibration offers a complete selection of dry-block calibrators, Micro-Baths, and infrared calibrators (i.e. blackbody calibrators) for temperature calibration at the accuracies required by todayâs industrial processes.
Field Metrology Well thermometer calibrators
| Model | Range | Accuracy | Description/Features |
| 9142 | â25 °C to 150 °C | Âą 0.2 °C | Light-weight portable and fast Reads and documents °C, mV, W, and 4-20 mA 24 volt loop power Includes accredited certificate of calibration |
| 9143 | 33 °C to 350 °C | ¹ 0.2 °C | |
| 9144 | 50 °C to 660 °C | ¹ 0.35 °C at 50 °C ¹ 0.35 °C at 420 °C ¹ 0.5 °C at 660 °C | |
| 9190A | â95 °C to 140 °C | Accuracy: Âą 0.2 °C | Horizontal thermocouple furnace. Flexible configuration for calibrating thermocouple bundles, spools, and sheathed thermocouples. |
 Micro-Bath thermometer calibratorsÂ
| Model | Range | Accuracy | Description/Features |
| 6102 Micro-Bath | 35 °C to 200 °C 95 °F to 392 °F | Âą0.25 °C | Worldâs smallest calibration bath. Stability to Âą0.02 °C. Stirred 2.5-inch-diameter tank. |
| 7102 Micro-Bath | â5 °C to 125 °C 23 °F to 257 °F | Âą0.25 °C | Portable bath to â5 °C. No refrigerationâsolid-state cooling. Stability to Âą0.015 °C. |
| 7103 Micro-Bath | â30 °C to 125 °C â22 °F to 257 °F | Âą0.25 °C | Ultracold Micro-Bath reaches â30 °C. No refrigeration or external cooling needed. Stability to Âą0.03 °C. |
 Handheld dry-well thermometer calibrators
| Model | Range | Accuracy | Description/Features |
| 9100S Handheld Dry-Well | 35 °C to 375 °C 95 °F to 707 °F | Âą0.25 °C at 100 °C ¹0.5 °C at 375 °C | Worldâs smallest dry-well. Fixed block with 4-inch well depth. Four hole patterns available. |
| 9102S Handheld Dry-Well | â10 °C to 122 °C 14 °F to 252 °F | Âą0.25 °C | Handheld unit cools to â10 °C. Two 0.5-inch-diameter, removable sleeves. |
 Field dry-well thermometer calibrators
| Model | Range | Accuracy | Description/Features |
| 9009 Dual-Block Calibrator | â15 °C to 350 °C 5 °F to 662 °F | Cold block: Âą0.2 °C Hot block: Âą0.6 °C | Dual-block industrial dry-well. Each block has two wells with removable sleeves. Water- and air-tight enclosure. |
| 9103 Field Dry-Well | â25 °C to 140 °C â13 °F to 284 °F | Âą0.25 °C | Small, lightweight field calibrator reaches â25 °C. Stability to Âą0.02 °C. Calibrates up to six probes at once. |
| 9140 Field Dry-Well | 35 °C to 350 °C 95 °F to 662 °F | ¹0.5 °C | Portable field calibrator. Choose from four multi-hole, removable inserts. |
| 9141 Field Dry-Well | 50 °C to 650 °C 122 °F to 1202 °F | ¹0.5 °C to 400 °C ¹1 °C to 650 °C | High-temp field calibrator. Interface-it software and RS-232 included. Extremely small and fast for temperature range. |
| 3125 Surface Calibrator | 35 °C to 400 °C 95 °F to 752 °F | ¹0.5 °C to 200 °C ¹1.0 °C to 400 °C | Calibrates surface sensors. Plate stability of ¹0.3 °C. |
 Infrared calibratorsÂ
Precision Infrared Calibrators
| Model | Range | Accuracy | Description/Features |
| 4180 | â15 °C to 120 °C | ¹ 0.40 °C at â15 °C ¹ 0.40 °C at 0 °C ¹ 0.50 °C at 50 °C ¹ 0.50 °C at 100 °C ¹ 0.55 °C at 120 °C | Fast, portable and easy to use Correct target size for most thermometers Calibration solutions from â15 °C to 500 °C (5 °F to 932 °F) Radiometrically calibrated for traceable and consistent results |
| 4181 | 35 °C to 500 °C | ¹ 0.35 °C at 35 °C ¹ 0.50 °C at 100 °C ¹ 0.70 °C at 200 °C ¹ 1.20 °C at 350 °C ¹ 1.60 °C at 500 °C | |
| 9132 | 50 °C to 500 °C 122 °F to 932 °F | ¹0.5 °C at 100 °C ¹0.8 °C at 500 °C | Certifies most handheld pyrometers. Short heating and cooling times. |
| 9133 | â30 °C to 150 °C  â22 °F to 302 °F | Âą0.4 °C | Calibrates at cold temperatures. Gets to desired temperature quickly. |
 Metrology Well high accuracy temperature and thermometer calibrators
| Model | Range | Accuracy | Description/Features |
| 9170 | â45 °C to 140 °C (â49 °F to 284 °F) | Âą0.1 °C | Best-performing industrial heat sources (accuracy, stability, uniformity) in the world. Immersion depth to 203 mm (8 in). Optional ITS-90 reference input reads PRTs to Âą0.006 °C. Temperature range from â45 °C to 700 °C. |
| 9171 | â30 °C to 155 °C (â22 °F to 311 °F) | Âą0.1 °C | |
| 9172 | 35 °C to 425 °C (95 °F to 797 °F) | ¹0.1 °C at 100 °C ¹0.15 °C at 225 °C ¹0.2 °C at 425 °C | |
| 9173 | 50 °C to 700 °C (122 °F to 1292 °F) | ¹0.2 °C at 425 °C ¹0.25 °C at 660 °C |
 Zero point dry-well
| Model | Range | Stability | Description/Features |
| 9101 | 0 °C 32 °F | Âą0.05 °C | Solid-state cooling. Replaces messy ice bathsâeasy to operate. Three wells, each 6 inches deep. |
 Dual block dry-wellÂ
| Model | Range | Stability | Description/Features |
| 9011 Hot Block Cold Block | 50 °C to 670 °C 122 °F to 1238 °F | Âą0.15 °C at 100 °C ¹0.65 °C at 600 °C | Combined ranges from â30 °C to 670 °C. 1 unit â 2 blocks. Two independent temperature controllers (hot and cold side). Stability: Âą0.01 °C. Multi-hole inserts hold up to 8 probes at once. |
| â30 °C to 140 °C â22 °F to 284 °F | Âą0.25 °C (insert wells) ¹0.65 °c (fixed wells) |
 FurnacesÂ
| Model | Range | Stability | Description/Features |
| 9150 Thermocouple Furnace | 150 °C to 1200 °C 302 °F to 2192 °F | ¹0.5 °C | Benchtop thermocouple furnace. Interchangeable insert sleeves. Fast heating and cooling. |
| 9118A Thermocouple Calibration Furnace | 300 °C to 1200 °C | ¹ 0.2 °C (without block), ¹ 0.1 °C (with block) | Horizontal thermocouple furnace. Flexible configuration for calibrating thermocouple bundles, spools, and sheathed thermocouples. |