Fluke 179/61 Industrial Multimeter and Infrared Thermometer Combo Kit

Model#: Fluke 179/61 Kit
  • Fluke 179/61 Industrial Multimeter and Infrared Thermometer Combo Kit 1

āļ āļēāļžāļĢāļ§āļĄāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒ: Fluke 179/61 Industrial Multimeter and Infrared Thermometer Combo Kit

āļŠāļļāļ”āļĢāļ§āļĄāļœāļĨāļīāļ•āļ āļąāļ“āļ‘āđŒāļĄāļąāļĨāļ•āļīāļĄāļīāđ€āļ•āļ­āļĢāđŒāđāļĨāļ°āđ€āļ—āļ­āļĢāđŒāđ‚āļĄāļĄāļīāđ€āļ•āļ­āļĢāđŒāļ­āļīāļ™āļŸāļĢāļēāđ€āļĢāļ”

āļŠāļĢāđ‰āļēāļ‡āļ‚āļķāđ‰āļ™āļŠāļģāļŦāļĢāļąāļšāļ‡āļēāļ™āļ­āļļāļ•āļŠāļēāļŦāļāļĢāļĢāļĄ, HVAC āđāļĨāļ°āļāļēāļĢāļ‹āđˆāļ­āļĄāļšāļģāļĢāļļāļ‡āļ­āļēāļ„āļēāļĢ āļĄāļąāļĨāļ•āļīāļĄāļīāđ€āļ•āļ­āļĢāđŒ True-rms āļ—āļĩāđˆāđāļ‚āđ‡āļ‡āđāļāļĢāđˆāļ‡ āļžāļĢāđ‰āļ­āļĄāđ€āļ—āļ­āļĢāđŒāđ‚āļĄāļĄāļīāđ€āļ•āļ­āļĢāđŒāđƒāļ™āļ•āļąāļ§āđ€āļžāļ·āđˆāļ­āđāļāđ‰āđ„āļ‚āļ›āļąāļāļŦāļēāļ”āđ‰āļēāļ™āđ„āļŸāļŸāđ‰āļēāđāļĨāļ°āđ„āļŸāļŸāđ‰āļēāđ€āļ„āļĢāļ·āđˆāļ­āļ‡āļāļĨ āļžāļĢāđ‰āļ­āļĄāļ”āđ‰āļ§āļĒāđ€āļ—āļ­āļĢāđŒāđ‚āļĄāļĄāļīāđ€āļ•āļ­āļĢāđŒāļ­āļīāļ™āļŸāļĢāļēāđ€āļĢāļ”āļ—āļĩāđˆāļ™āļģāļ—āļēāļ‡āļ”āđ‰āļ§āļĒāđ€āļĨāđ€āļ‹āļ­āļĢāđŒ āđ„āļĄāđˆāļĄāļĩāļāļēāļĢāļŠāļąāļĄāļœāļąāļŠ āļŠāļģāļŦāļĢāļąāļšāļāļēāļĢāļ§āļąāļ”āļ­āļļāļ›āļāļĢāļ“āđŒāļ—āļĩāđˆāļŦāļĄāļļāļ™āļŦāļĢāļ·āļ­āļĄāļĩāļžāļĨāļąāļ‡āļ‡āļēāļ™ āļ—āļąāđ‰āļ‡āļŦāļĄāļ”āļ™āļĩāđ‰āļĢāļ§āļĄāļ­āļĒāļđāđˆāđƒāļ™āļāļĢāļ°āđ€āļ›āđ‹āļēāļ—āļĩāđˆāļ—āļ™āļ—āļēāļ™

āļ‚āđ‰āļ­āļĄāļđāļĨāļˆāļģāđ€āļžāļēāļ°: Fluke 179/61 Industrial Multimeter and Infrared Thermometer Combo Kit

Fluke 179 Digital Multimeter

Specifications
Voltage DCAccuracy1Âą(0.09% + 2)
Max. resolution0.1 mV
Maximum1000 V
Voltage ACAccuracy1Âą(1.0% + 3)
Max. resolution0.1 mV
Maximum1000 V
Current DCAccuracy1Âą(1.0% + 3)
Max. resolution0.01 mA
Maximum10 A
Current ACAccuracy1Âą(1.5% + 3)
Max. resolution0.01 mA
Maximum10 A
ResistanceAccuracy1Âą(0.9% + 1)
Max. resolution0.1 ÎĐ
Maximum50 MÎĐ
CapacitanceAccuracy1Âą(1.2% + 2)
Max. resolution1 nF
Maximum10,000 ÂĩF
FrequencyAccuracy1Âą(0.1% + 1)
Max. resolution0.01 Hz
Maximum100 kHz
TemperatureAccuracy1Âą(1.0% + 10)
Max. resolution0.1°C
Range-40°C/400°C
1. Accuracies are best accuracies for each function
Environmental Specifications
Operating temperature-10°C to +50°C
Storage temperature-30°C to +60°C
Humidity (without condensation)0% - 90% (0°C - 35°C)
0% - 70% (35°C -50°C)
Safety Specifications
Overvoltage categoryEN 61010-1 to 1000 V CAT III
EN 61010-1 to 600 V CAT IV
Agency approvalsUL, CSA, TÜV listed and VDE Pending
Mechanical and General Specifications
Size43 x 90 x 185 mm
Weight420 g
WarrantyLifetime
Battery lifeAlkaline ~200 hours typical, without backlight

Fluke 61 IR Thermometer

Specifications
Backlit display for use in poorly lit areasYes
Holds temperature readingsYes
Range-18 to 275°C (-0 to 525°F)
MIN/MAX/AVGN/A
DataloggingN/A
Distance to spot ratio8:1
Hi-Lo alarmN/A
Optional RTD probe (contact temperature measurement)N/A
EmissivityFixed at 0.95
Measurement accuracy-18°C (0°F) to -1°C (30°F)¹3°C (5°F)
above -1°C (30°F) to 275°C (525°F)¹2% of reading or 2°C (3.5°F)
(With the instrument stable between 23-25°C)

āļĢāļļāđˆāļ™: Fluke 179/61 Industrial Multimeter and Infrared Thermometer Combo Kit

Fluke 179/61 Kit

āļ­āļļāļ›āļāļĢāļ“āđŒāļ—āļĩāđˆāļĄāļĩāđƒāļŦāđ‰


āļ‹āļ·āđ‰āļ­āđ€āļĨāļĒ
  • C800 āļāļĨāđˆāļ­āļ‡āđāļ‚āđ‡āļ‡āļŠāļģāļŦāļĢāļąāļšāļĄāļīāđ€āļ•āļ­āļĢāđŒāđāļĨāļ°āļ­āļļāļ›āļāļĢāļ“āđŒāđ€āļŠāļĢāļīāļĄ
  • āļĄāļąāļĨāļ•āļīāļĄāļīāđ€āļ•āļ­āļĢāđŒ Fluke 179 True RMS
  • āđ€āļ—āļ­āļĢāđŒāđ‚āļĄāļĄāļīāđ€āļ•āļ­āļĢāđŒāļ­āļīāļ™āļŸāļĢāļēāđ€āļĢāļ” Fluke 61
āđāļŠāļ—āļāļąāļšāļœāļđāđ‰āļŠāđˆāļ§āļĒ Fluke āļ‚āļ­āļ‡āđ€āļĢāļē
āļĨāđ‰āļēāļ‡āđāļŠāļ—