Fluke 1587 FC Insulation Multimeter

Model#:FLK-1587-FCPart#:4691215UPC#:0 95969 79662 0
Fluke 1587 FC Insulation Multimeter is rated 4.7 out of 5 by 31.
  • y_2025, m_7, d_13, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_5, tr_26
  • loc_en_US, sid_3739310948404, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.88ms
  • REVIEWS, PRODUCT
  • Fluke 1587 FC Insulation Multimeter
  • Fluke 1587 FC Insulation Multimeter
  • Fluke 1587 FC Insulation Multimeter
  • Fluke 1587 FC Insulation Multimeter
  • Video Player is loading.
    Current Time 0:00
    Duration 2:45
    Loaded: 0.00%
    Stream Type LIVE
    Remaining Time 2:45
     
    1x
      • Chapters
      • descriptions off, selected
      • captions off, selected
      • en (Main), selected
    • Video Player is loading.
      Current Time 0:00
      Duration 3:21
      Loaded: 0.00%
      Stream Type LIVE
      Remaining Time 3:21
       
      1x
        • Chapters
        • descriptions off, selected
        • captions off, selected
        • en (Main), selected
      1. Fluke 1587 FC Insulation Multimeter
      2. Fluke 1587 FC Insulation Multimeter
      3. Fluke 1587 FC Insulation Multimeter
      4. Fluke 1587 FC Insulation Multimeter
      5. Fluke 1587 FC Tips and Tricks
      6. How to test a motor with the 1587 FC

      Key features

      Read more
      In stock
      $1,038.99
      FREE Shipping
      30-day Returns

      Product overview: Fluke 1587 FC Insulation Multimeter

      Keep yourself safe. Find hidden problems faster. Put the paperwork down.

      Fluke Connect + Fluke's 1587 FC Insulation Multimeter helps you identify tough problems, fix, and wirelessly communicate your work quickly and easily - all at a safe distance.

      Add diagnostics with Fluke Connect

      The Fluke 1587 FC is Fluke Connect-enabled so you can download the free Fluke Connect® Measurements app to your smartphone and gain additional functions, including:

      • Safety first. Keep yourself out of harm’s way by monitoring your test measurements remotely.
      • Prove your job is done right by quickly seeing and sharing measurement results wirelessly with your smartphone.
      • Quickly find problems by saving and comparing measurements over time on a wireless device.
      • PI/DAR timed ratio tests with TrendIt™ graphs to identify moisture and contaminated insulation problems faster
      • Memory storage through Fluke Connect that saves measurements to your phone or the cloud and eliminates the need to write down results. Reduces errors and saves data for historical tracking over time
      • Temperature compensation to establish accurate baselines and relevant historical comparisons
      • Historical tracking and trending of assets to identify insulation degradation over time and allow real-time decisions to be made in the field with Fluke Connect® Assets (sold separately)
      • Provides memory storage through Fluke Connect Measurements to eliminate the need to write down results
      • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
      • Supports historical tracking and asset trending of assets to identify degradation over time with Fluke Connect® Assets (sold separately)
      • Incorporates VFD low-pass filter for accurate variable frequency motor drive measurements
      • Includes auto-discharge of capacitive voltage for added user protection
      • Measures ac/dc voltage, dc millivolts, ac/dc milliamps, resistance, and continuity
      • Includes capacitance, diode test, temperature, min/max, frequency measurements and insulation test smoothing reading
      • Automatically powers off to save battery power
      • Comes with remote probe, test leads, alligator clips, K-type thermocouple, hard case, and three-year warranty.

      Useful resources and rugged tools for Solar professionals

       
       Fluke 115 Field Technicians Digital MultimeterFluke 87V Industrial MultimeterFluke 3000 FC Series Wireless MultimeterFluke 1587 FC Insulation MultimeterFluke 279 FC True-rms Thermal Multimeter
      CAT ratingCAT III 600 VCAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      CAT III 1000 V
      CAT IV 600 V
      True-rms readings
      Voltage AC/DC600 V1000 V1000 V1000 V1000 V
      Current AC/DC10 A10 A400 mA400 mA2500 A AC (with iFlex)
      Resistance40 MΩ50 MΩ50 MΩ50 MΩ50 MΩ
      Capacitance10,000 μF10,000 μF10,000 μF10,000 μF10,000 μF
      Temperature--200.0 °C to 1090 °Cwith t3000 FC-40 °C to 537 °CInfrared camera
      -10 °C to 200 °C
      Infrared camera----
      Additional
      measurement
      capabilities
      Continuity/diode testFrequency,
      continuity/diode test,
      motor drive (VFD)
      measurement,
      duty cycle,
      microamps, analog
      bar graph, relative
      reference
      Frequency,
      continuity/diode test.
      Able to connect to
      three 3000 FC
      modules.
      Frequency, Pi/DAR
      timed ratio tests,
      continuity/diode test, motor drive (VFD)
      measurement,
      microamps, relative
      reference
      Frequency,
      continuity/diode test,
      motor drive (VFD)
      measurement

      What's in the box:

      • Fluke 1587 FC Insulation Multimeter
      • Remote probe
      • Test leads
      • Alligator clips
      • K-type thermocouple
      • Soft case
      • User documentation

      Specifications: Fluke 1587 FC Insulation Multimeter

      Electrical Specifications
      AC voltage measurement
      Range
      600.0 mVResolution0.1 mV
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
      6.000 VResolution0.001 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
      60.00 VResolution0.01 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)
      600.0 VResolution0.1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹
      1000 VResolution1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
      Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts)±(2% + 3)¹
      ¹ 1 kHz bandwidth
      Low-Pass Filter Voltage 
      Range
      600.0 mVResolution0.1 mV
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
      6.000 VResolution0.001 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
      60.00 VResolution0.01 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
      600.0 VResolution0.1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(1% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
      1000 VResolution1 V
      Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts)±(2% + 3)
      Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts)+(2% + 3), -(6% - 3)
      DC Voltage Measurement
      RangeResolutionAccuracy ±(% of Rdg + Counts)
      6.000 V dc0.001 V±(0.09% + 2)
      60.00 V dc0.01 V±(0.09% + 2)
      600.0 V dc0.1 V±(0.09% + 2)
      1000 V dc1 V±(0.09% + 2)
      Input impedance 10 MΩ (nominal), <100 pF
      Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz
      Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
      Accuracies apply to ± 100% of range
      DC Millivolts Measurement
      RangeResolutionAccuracy ±(% of Rdg + Counts)
      600.0 mVdc0.1 mV±(0.1% + 1)
      DC and AC Current Measurement
      AC 45 Hz to 1000 Hz
      Range400 mA
      Resolution0.1 mA
      Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹
      Burden voltage (Typical)2 mV/mA
      Range60 mA 
      Resolution0.01 mA 
      Accuracy ±(% of Rdg+Counts)±(1.5% + 2)¹
      Burden voltage (Typical)2 mV/mA
      DC
      Range400 mA
      Resolution0.1 mA
      Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
      Burden voltage (Typical)2 mV/mA
      Range60 mA
      Resolution0.01 mA
      Accuracy ±(% of Rdg+Counts)±(0.2% + 2)
      Burden voltage (Typical)2 mV/mA
      Overload600 mA for 2 minutes maximum
      Fuse protection for mA input0.44 mA, 1000 V, IR 10 kA
      AC conversionInputs are ac-coupled and calibrated to the rms value of sine wave input
      Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ≤1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
      ¹ 1 kHz bandwidth
      Ohms Measurement
      RangeResolutionAccuracy +(% of Rdg+Counts)¹
      600.0 Ω0.1 Ω±(0.9% + 2)
      6.000 kΩ0.001 kΩ±(0.9% + 2)
      60.00 kΩ0.01 kΩ±(0.9% + 2)
      600.0 kΩ0.1 KΩ±(0.9% + 2)
      6.000 MΩ0.001 MΩ±(0.9% + 2)
      50.0 MΩ ²0.01 MΩ±(1.5% + 3)
      Overload protection 1000 V rms or dc
      Open circuit test voltage <8.0 V dc
      Short circuit current <1.1 mA
      ¹ Accuracies apply from 0% to 100% of range
      ² Up to 80% relative humidity
      Diode Test
      Diode test indicationDisplay voltage drop: 0.6 V at1.0 mA nominal test current:
      Accuracy±(2% + 3)
      Continuity Test
      Continuity indicationContinuous audible tone for testresistance below 25 Ω and off above 100 Ω. Maximum Reading; 1000 Ω
      Open circuit voltage<8.0 V
      Short circuit current1.0 mA typical
      Overload protection1000 V rms
      Response time>1 m sec
      Frequency Measurement
      RangeResolutionAccuracy ±(% of Rdg+Counts)
      99.99 Hz 0.01 Hz ±(0.1% + 1)
      999.9 Hz 0.1 Hz ±(0.1% + 1)
      9.999 kHz 0.001 kHz ±(0.1% + 1)
      99.99 kHz 0.01 kHz ±(0.1% + 1)
      Frequency Counter Sensitivity
      600.0 mV ac V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 mV 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz150.0 mV 
      DC Trigger Levels¹ to 20 kHz²NA
      6.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 1.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz1.5 V 
      DC Trigger Levels¹ to 20 kHz²-400.0 mV and 2.5 V
      60.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 10.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz36.0 V 
      DC Trigger Levels¹ to 20 kHz²1.2 V and 4.0 V
      600.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 100.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz-
      DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V
      1000.0 V V ac Sensitivity (RMS Sine Wave)¹  5 Hz to 20 kHz 300.0 V 
      V ac Sensitivity (RMS Sine Wave)¹  20 kHz to 100 kHz-
      DC Trigger Levels¹ to 20 kHz²12.0 V and 40.0 V
      ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
      ² Usable to 100 kHz with full scale input
      Capacitance
      Range Resolution Accuracy ±(% of Rdg+Counts)
      1000 nF 1 nF±(1.2% + 2)
      10.00 μF 0.01 μF±(1.2% + 2)
      100.0 μF 0.1 μF±(1.2% ±90 counts)
      9999 μF 1 μF±(1.2% ±90 counts)
      Temperature Measurement
      Range Resolution Accuracy ±(% of Rdg+Counts)¹
      -40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)
      -40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)
      ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
      Insulation Specifications
      Measurement range0.01 MΩ to 2 GΩ
      Test voltages50, 100, 250, 500, 1000 V
      Test voltage accuracy+20%, -0%
      Short-circuit test current1 mA nominal
      Auto dischargeDischarge time <0.5 second for C = 1 μF or less
      Live circuit detectionInhibit test if terminal voltage > 30 V prior to initialization of test
      Maximum capacitive loadOperable with up to 1 μF load
      Output Voltage
      50 V (0% to +20%)Display range0.01 to 6.00 MΩ
      Resolution0.01 MΩ
      Test current1 mA @ 50 kΩ
      Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
      Display range6.0 to 50.0 MΩ
      Resolution0.1 MΩ
      Test current1 mA @ 50 kΩ
      Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
      100 V (0% to +20%)Display range0.01 to 6.00 MΩ
      Resolution0.01 MΩ
      Test current1 mA @ 100 kΩ
      Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
      Display range6.0 to 60.0 MΩ
      Resolution0.1 MΩ
      Test current1 mA @ 100 kΩ
      Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
      Display range60 to 100 MΩ 
      Resolution1 MΩ
      Test current1 mA @ 100 kΩ
      Resistance accuracy ±(% of Rdg + Counts)±(3% + 5 counts)
      250 V (0% to +20%)Display range0.1 to 60.0 MΩ 
      Resolution0.1 MΩ
      Test current1 mA @ 250 kΩ 
      Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
      Display range60 to 250 MΩ 
      Resolution1 MΩ
      Test current1 mA @ 250 kΩ 
      Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
      500 V (0% to +20%)Display range0.1 to 60.0 MΩ
      Resolution0.1 MΩ
      Test current1 mA @ 500 kΩ 
      Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
      Display range60 to 500 MΩ
      Resolution1 MΩ
      Test current1 mA @ 500 kΩ 
      Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
      1000 V (0% to +20%)Display range0.1 to 60.0 MΩ 
      Resolution0.1 MΩ
      Test current1 mA @ 1 MΩ
      Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
      Display range60 to 600 MΩ 
      Resolution1 MΩ
      Test current1 mA @ 1 MΩ
      Resistance accuracy ±(% of Rdg + Counts)±(1.5% + 5 counts)
      Display range0.6 to 2.0 GΩ 
      Resolution100 MΩ 
      Test current1 mA @ 1 MΩ
      Resistance accuracy ±(% of Rdg + Counts)±(10% + 3 counts)
      General Specifications
      Maximum voltage applied to any terminal and common1000 V
      Storage temperature-40 °C to 60 °C (-40 °F to 140 °F)
      Operating temperature-20 °C to 55 °C (-4 °F to 131 °F)
      Temperature coefficient0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
      Relative humidityNoncondensing
      0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
      0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
      0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
      VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
      Radio frequency communication2.4 GHz ISM Band
      Radio frequency certificationFCC: T68-FBLE, IC: 6627A-FBLE
      Electromagnetic Compatibility 
      InternationalIEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
      Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
      Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes.  There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
      Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
      Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
      Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
      USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
      Enclosure protectionIEC 60529: IP40 (non-operating)
      Safety
      IEC 61010-1Pollution Degree 2
      IEC 61010-2-033CAT IV 600 V / CAT III 1000 V
      Batteries Four AA batteries (IEC LR6)
      Battery lifeMeter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
      Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
      Weight550 g (1.2 lb)
      AltitudeOperating2000 m
      Storage12,000 m
      Over-range capability110% of range except for capacitance which is 100%
      Frequency overload protection<107 V Hz
      Fuse protection for mA input0.44A, 1000 V, IR 10 kA

      Models: Fluke 1587 FC Insulation Multimeter

      FLK-1587-FC
      Fluke 1587 FC Insulation Multimeter
      Part#: 4691215
      UPC#: 0 95969 79662 0
      Includes:
      • Remote probe
      • Test leads
      • Alligator clips
      • K-type thermocouple
      • Soft case
      • User documentation
      • y_2025, m_7, d_13, h_8CST
      • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
      • cp_1, bvpage1
      • co_hasquestionsanswers, tq_4
      • loc_en_US, sid_3739310948404, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
      • clientName_fluke
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getContent, 21.62ms
      • QUESTIONS, PRODUCT
      • y_2025, m_7, d_13, h_8
      • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
      • cp_1, bvpage1
      • co_hasreviews, tv_5, tr_26
      • loc_en_US, sid_3739310948404, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
      • clientName_fluke
      • bvseo_sdk, p_sdk, 3.2.1
      • CLOUD, getReviews, 23.01ms
      • REVIEWS, PRODUCT
      Please enable cookies to view product reviews.
      Chat with ourFluke assistant
      Clear Chat

      Hi, I'm your virtual assistant, I will do my very best to help you navigate all things Fluke related. You can ask me anything!

      I'm new and might make a few mistakes. For safe use of Fluke tools, refer to the product manuals, safety sheets, and your company's safety requirements. To speak with a person, visit our Contact Us or Talk to Sales page. For information on how we handle personal data, see our Privacy Policy