Fluke 902 True RMS HVAC Clamp Meter

Model#: Fluke 902Part#: 2556988UPC#: 0 95969 33214 9
Fluke 902 True RMS HVAC Clamp Meter is rated 4.0 out of 5 by 28.
  • y_2026, m_9, d_22, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_28
  • loc_en_US, sid_fluke-902, prod, sort_[SortEntry(order=RATING, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 186.19ms
  • REVIEWS, PRODUCT
  • Fluke 902 True RMS HVAC Clamp Meter
  • Fluke 902 True RMS HVAC Clamp Meter
  • Fluke 902 True RMS HVAC Clamp Meter
Discontinued

Key features

  • Designed for HVAC applications with capacitance, DC Current (µA), and temperature measurements
  • Small body and jaws fit perfectly in your hand and into tight places
  • Handy 'Display Hold' button keeps measurements on the display
  • Meter controls are positioned so current measurements can be done with one hand (index finger on clamp opening lever and thumb on rotary switch)
  • Large, backlit display is easy-to-see in less than ideal conditions
  • Auto shut-off maximizes battery life so the meter works when you need it
  • Three year warranty
This product is discontinued or reclassified

Product overview: Fluke 902 True RMS HVAC Clamp Meter

Do Your Job Safely and Accurately

If you're an HVAC service technician, the 902 helps you get more done without the need to carry multiple meters. That's because it is designed for the systems you service and install daily. With True RMS technology and a CAT III 600 V rating, you can troubleshoot and maintain HVAC equipment safely and with confidence in the results.

Specifications: Fluke 902 True RMS HVAC Clamp Meter

Specifications
Voltage DCRange0 – 600.0 V
Accuracy1% ±5 counts
Voltage AC (True RMS)Range0 – 600.0 V
Accuracy1% ±5 counts (50/60 Hz)
Current AC (True RMS)Range0 – 600.0 A
Accuracy2.0% ±5 counts (50/60 Hz)
Current DCRange0 - 200.0 µA
Accuracy1.0% ±5 counts
ResistanceRange0 – 9999 Ω
Accuracy1.5% ±5 counts
Continuity≤ 30 Ω
Temperature1
(Type K Thermocouple)
Range-10°C to 400°C (-14°F to 752°F)
Accuracy±1.0% + 0.8°C (±1.0% + 1.5°F) typical
Range-40°C to -10°C (-40°F to -14°F)
Accuracy±5.0% + 1.5°C (±5.0% + 3.3°F) typical
CapacitanceRange1 – 1000 µF
Accuracy1.9% ±2 counts
1. Error does not include Type K Thermocouple errors
Mechanical and General Specifications
Weight1.5 lbs (.7 kg)
Dimensions10.75 x 4.25 x 2.44 in (27.3 x 10.8 x 6.2 cm)
Battery type(2) AA Alkaline Batteries

Models: Fluke 902 True RMS HVAC Clamp Meter

Fluke 902

Fluke 902 True RMS HVAC Clamp Meter

Part#: 2556988
UPC#: 0 95969 33214 9

Includes

  • AA alkaline batteries (2)
  • Users manual w/safety information
  • Soft carrying case
  • TL75 Test Leads (1 pair)
  • 80BK Integrated DMM Temperature Probe (1)
Fluke 902 True RMS HVAC Clamp Meter is rated 4.0 out of 5 by 28.
Rated 5 out of 5 by from All in one HVAC meter I love this meter, it does everything an HVAC tech could ask for. Fluke is the only way to go for a good, dependable meter. I love the fact that I do not have to cary three meters around to do the job.
Date published: 2012-06-08
Rated 5 out of 5 by from Great all-in-one HVAC meter! I've worked as an HVAC technician for 12 years and have come to depend on the reliability of Fluke meters. The Fluke 902 is a great practically a necessity for any HVAC tech. It is durable, reliable, and capable of testing the necessary items found in day to day troubleshooting. The milliamp testing feature is great for troubleshooting thermocouples. I highly recommend this meter for any HVAC tech!
Date published: 2012-06-07
Rated 5 out of 5 by from Great all-in-one HVAC meter! I've worked as a HVAC technician for 12 years now and have always trusted Fluke products. The Fluke 902 is an excellent combination for any HVAC professional. It's very durable, reliable, and accurate. Highly recommend this meter!
Date published: 2012-06-07
Rated 5 out of 5 by from This meter has all the functions I need in one tool. I work in the HVAC industry and this meter has all the functions I need in one tool. I use to carry three meters around in my tool kit, but now I just carry the 902. Great meter ! I love Fluke meters and have been using them for 18 years. I miss my old fluke 12, that was a great meter too.
Date published: 2012-05-19
Rated 4 out of 5 by from Very close to being the perfect time meter For an HVAC tech this meter is the only one you need to take out of your truck 95% of the time. The only time it falls short is with the ohms measurement limited to 9999. Many hvac sensors are over that and the meter fools you showing an open circuit. So I keep my old 87 around for those measurements.
Date published: 2016-12-08
Rated 4 out of 5 by from Versatile Hvac multimeter Ive used this meter for a year or so and dont have any complaints other than not being able to test 10k sensors.
Date published: 2016-12-08
Rated 4 out of 5 by from Great test equipment I bought this clamp meter 15 years ago and still have it today. I also like how fluke has the leads you can buy separately.
Date published: 2016-12-08
Rated 4 out of 5 by from may the force be with you! I've had my 902 for about 6 years now, it's been dropped from ladders, submerged in water and left in the back of a cold van on numerous occasions and always turns on immediately and works as good as day the day I purchased it. Buying a HVAC oriented multi meter in today's market can be quit like buying a car now, with so many different manufactures and prices it can be a hard decision to make to say the least. For all the features this meter provides and the long lasting craftsmanship from fluke this purchase was a no brainer and I wish I hadn't spent so much money before on junk HVAC meters, the only reason I gave this meter 4 out of 5 stars was due to the fact that it doesn't have a magnet or accessory port for a magnetic strap i.e. Similar to the 116 model bench meter. And the ohms scale should be higher, other than that this fluke skywalker has saved me time and money on numerous occasions and I look forward to using it for years to come.
Date published: 2016-12-07
Rated 4 out of 5 by from needs broader range of resistance reading great meter, but lacking one thing. ohm value scale too low, will not test potentiometers on most pieces of equipment
Date published: 2015-06-05
Rated 4 out of 5 by from 3rd 902 great meter for a hvac tech, capacitor checking very handy. hold button can be in the way, ohms at 10k doesn't match industry. would really like a 25k.ahve had 3 and would buy again. 25 yrs ex. very good product.
Date published: 2014-12-25
Rated 4 out of 5 by from Good meter, great customer service I purchased a HVAC combo kit with a 902 clamp meter and laser thermometer. I had them for about a year when the 902 quit working in clamp on amp mode. I contacted customer service, and sent the meter back. Within a week I received not a rebuilt meter, but a brand new one with a case ( the original didn't come with one)I was very impressed with the way they stand behind their product. In the future, all of my meters will be Fluke.
Date published: 2014-04-03
Rated 4 out of 5 by from HANDS DOWN the best and most abused meter i own i bought this meter maybe 4 or 5 years ago and its all original.  works just as well as the first day i got it.  it is the most used (every single day) and abused meter i own, and at the end of the day it ask for more.  It has most of the functions i need everyday (besides mA measurements, and a kind of low max resistance of 9999 [i work with a lot of 10k and 20k temp sensors]) and is extremely accurate.  I always recommend this meter to anybody i work with.  The reason i gave it 4 stars is because of the above mentioned mA measurement and low resistance , and the shortfall of how and where you can put your meter while in use.  like some of the competition like fieldpiece(and i use the term "competition" loosly), have a type of magnet so you hang the meter and have 2 free hands to take measurements, and also have a spot on the body of the meter towards the top, preferably on the side, to attach one of the leads, so you can take measurements and see what the readings are and not have to readjust and look away. besides those (im picky with my tools) areas, its the best meter for the hvac field mechanic...
Date published: 2014-03-28
Rated 4 out of 5 by from A good overall tool. . .almost perfect I've had the 902 for a few years as a replacement to my fluke 16. The amp clamp is a good addition to the meter. It is simple to use, even better than the 16 as the thumb wheel gets you to the setting you want quickly. My only two complaints about the meter it is not as rugged as the fluke 16 ( that thing was bomb proof) as the rubber grip on the amp jaw lever has come off and the wheel has given me problems ocasionally locking up. The other complaint is that it does not read DC milivolts and if you are trying to measure thermocouples this meter can not measure them. The 902 has been a good meter but wont take to much punishment. As such mine has finally bit the dust and I will be looking for a meter that has all the features of the 902 but can read milivolts. If reading milivolts is not a feature you need then this will be a good meter for you. PS the case didn't hold up as well as the fluke 16's case either.
Date published: 2012-07-11
Rated 4 out of 5 by from Good meter I've been in HVAC industry for about 6 years now and have used an assortment of meters. I like the 902 for the fast voltage and capacitance readings (most other meters take a long time to read). That being said, there are a few things that could be improved upon. - A DC MV range would be great for checking thermocouples. - 0.01 resolution for amperage would be awesome (like the 322) - And a higher Ohm range. 10K ohm is not very useful. Have found a couple grounded compressors the meter couldn't pick up (checked with my 116 and got about 22M Ohm to ground). - Perhaps a dedicated K type thermocouple input for temperature. Those are the only things I would like to see improved, otherwise this meter is a great tool to have. I like having the quality and accuracy of FLUKE in my tool pouch.
Date published: 2012-06-13
Rated 3 out of 5 by from ok, but the continuity beep is not loud enough. the 10k ohm meter range is not high enough.
Date published: 2012-07-12
Rated 2 out of 5 by from CAL error code I have a old 902 TRUE RMS Fluke meter, and when I open it a CAL code appear. Probably need to be calibrated.Do you have a solution to reset this code erraor?
Date published: 2025-03-26
Rated 2 out of 5 by from Multiple issues with Amp Clamp I'm on my 2nd 902 now and this is the second one to have issues reading amperage. I have to open and close the clamp several time to get a reading which at that point I no longer trust what I'm seeing. Other than that it works fine but thats the main feature for these style of meters. Likely won't purchase another 902.
Date published: 2017-10-19
Rated 2 out of 5 by from Can't test a 10K sensor! How do we call a meter an HVAC meter when we can't test a 10,000 ohm sensor the most common HVAC control sensor?
Date published: 2013-01-18
Rated 1 out of 5 by from Disappointed Bought this meter a few months ago, decided to go this route after having the same common problem with the UEI G2 phoenix of the screen glitching. The fluke 902 does not read DC millivolts which I find goes against it advertising as a HVAC meter. As well, it won’t read high resistance properly. I tried testing varistors with it and it will not register. Pull out the UEI and although the screen will periodically glitch, it properly reads resistance. I also don’t like that the beep on resistance is not able to be muted. Considering the cost of this meter, my expectations were much higher.
Date published: 2022-03-06
Rated 1 out of 5 by from Calibration? Calibration Information manual contains no calibration information other than "return to Fluke". I did not spend $22,000 for my 5500A's so that I could do performance tests! Return to Fluke? A Clamp Meter is now proprietary? Come on, guys! As a calibration service provider, I won't recommend products to my customers unless I can service them. The guys that use these meters need them serviced on-site and are not likely to send them out for certification.
Date published: 2013-03-27
  • y_2026, m_9, d_22, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_28
  • loc_en_US, sid_fluke-902, prod, sort_[SortEntry(order=RATING, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 49.19ms
  • REVIEWS, PRODUCT
Rated 5 out of 5 by from All in one HVAC meter I love this meter, it does everything an HVAC tech could ask for. Fluke is the only way to go for a good, dependable meter. I love the fact that I do not have to cary three meters around to do the job.
Date published: 2012-06-08
Rated 5 out of 5 by from Great all-in-one HVAC meter! I've worked as an HVAC technician for 12 years and have come to depend on the reliability of Fluke meters. The Fluke 902 is a great practically a necessity for any HVAC tech. It is durable, reliable, and capable of testing the necessary items found in day to day troubleshooting. The milliamp testing feature is great for troubleshooting thermocouples. I highly recommend this meter for any HVAC tech!
Date published: 2012-06-07
Rated 5 out of 5 by from Great all-in-one HVAC meter! I've worked as a HVAC technician for 12 years now and have always trusted Fluke products. The Fluke 902 is an excellent combination for any HVAC professional. It's very durable, reliable, and accurate. Highly recommend this meter!
Date published: 2012-06-07
Rated 5 out of 5 by from This meter has all the functions I need in one tool. I work in the HVAC industry and this meter has all the functions I need in one tool. I use to carry three meters around in my tool kit, but now I just carry the 902. Great meter ! I love Fluke meters and have been using them for 18 years. I miss my old fluke 12, that was a great meter too.
Date published: 2012-05-19
Rated 4 out of 5 by from Very close to being the perfect time meter For an HVAC tech this meter is the only one you need to take out of your truck 95% of the time. The only time it falls short is with the ohms measurement limited to 9999. Many hvac sensors are over that and the meter fools you showing an open circuit. So I keep my old 87 around for those measurements.
Date published: 2016-12-08
Rated 4 out of 5 by from Versatile Hvac multimeter Ive used this meter for a year or so and dont have any complaints other than not being able to test 10k sensors.
Date published: 2016-12-08
Rated 4 out of 5 by from Great test equipment I bought this clamp meter 15 years ago and still have it today. I also like how fluke has the leads you can buy separately.
Date published: 2016-12-08
Rated 4 out of 5 by from may the force be with you! I've had my 902 for about 6 years now, it's been dropped from ladders, submerged in water and left in the back of a cold van on numerous occasions and always turns on immediately and works as good as day the day I purchased it. Buying a HVAC oriented multi meter in today's market can be quit like buying a car now, with so many different manufactures and prices it can be a hard decision to make to say the least. For all the features this meter provides and the long lasting craftsmanship from fluke this purchase was a no brainer and I wish I hadn't spent so much money before on junk HVAC meters, the only reason I gave this meter 4 out of 5 stars was due to the fact that it doesn't have a magnet or accessory port for a magnetic strap i.e. Similar to the 116 model bench meter. And the ohms scale should be higher, other than that this fluke skywalker has saved me time and money on numerous occasions and I look forward to using it for years to come.
Date published: 2016-12-07
Rated 4 out of 5 by from needs broader range of resistance reading great meter, but lacking one thing. ohm value scale too low, will not test potentiometers on most pieces of equipment
Date published: 2015-06-05
Rated 4 out of 5 by from 3rd 902 great meter for a hvac tech, capacitor checking very handy. hold button can be in the way, ohms at 10k doesn't match industry. would really like a 25k.ahve had 3 and would buy again. 25 yrs ex. very good product.
Date published: 2014-12-25
Rated 4 out of 5 by from Good meter, great customer service I purchased a HVAC combo kit with a 902 clamp meter and laser thermometer. I had them for about a year when the 902 quit working in clamp on amp mode. I contacted customer service, and sent the meter back. Within a week I received not a rebuilt meter, but a brand new one with a case ( the original didn't come with one)I was very impressed with the way they stand behind their product. In the future, all of my meters will be Fluke.
Date published: 2014-04-03
Rated 4 out of 5 by from HANDS DOWN the best and most abused meter i own i bought this meter maybe 4 or 5 years ago and its all original.  works just as well as the first day i got it.  it is the most used (every single day) and abused meter i own, and at the end of the day it ask for more.  It has most of the functions i need everyday (besides mA measurements, and a kind of low max resistance of 9999 [i work with a lot of 10k and 20k temp sensors]) and is extremely accurate.  I always recommend this meter to anybody i work with.  The reason i gave it 4 stars is because of the above mentioned mA measurement and low resistance , and the shortfall of how and where you can put your meter while in use.  like some of the competition like fieldpiece(and i use the term "competition" loosly), have a type of magnet so you hang the meter and have 2 free hands to take measurements, and also have a spot on the body of the meter towards the top, preferably on the side, to attach one of the leads, so you can take measurements and see what the readings are and not have to readjust and look away. besides those (im picky with my tools) areas, its the best meter for the hvac field mechanic...
Date published: 2014-03-28
Rated 4 out of 5 by from A good overall tool. . .almost perfect I've had the 902 for a few years as a replacement to my fluke 16. The amp clamp is a good addition to the meter. It is simple to use, even better than the 16 as the thumb wheel gets you to the setting you want quickly. My only two complaints about the meter it is not as rugged as the fluke 16 ( that thing was bomb proof) as the rubber grip on the amp jaw lever has come off and the wheel has given me problems ocasionally locking up. The other complaint is that it does not read DC milivolts and if you are trying to measure thermocouples this meter can not measure them. The 902 has been a good meter but wont take to much punishment. As such mine has finally bit the dust and I will be looking for a meter that has all the features of the 902 but can read milivolts. If reading milivolts is not a feature you need then this will be a good meter for you. PS the case didn't hold up as well as the fluke 16's case either.
Date published: 2012-07-11
Rated 4 out of 5 by from Good meter I've been in HVAC industry for about 6 years now and have used an assortment of meters. I like the 902 for the fast voltage and capacitance readings (most other meters take a long time to read). That being said, there are a few things that could be improved upon. - A DC MV range would be great for checking thermocouples. - 0.01 resolution for amperage would be awesome (like the 322) - And a higher Ohm range. 10K ohm is not very useful. Have found a couple grounded compressors the meter couldn't pick up (checked with my 116 and got about 22M Ohm to ground). - Perhaps a dedicated K type thermocouple input for temperature. Those are the only things I would like to see improved, otherwise this meter is a great tool to have. I like having the quality and accuracy of FLUKE in my tool pouch.
Date published: 2012-06-13
Rated 3 out of 5 by from ok, but the continuity beep is not loud enough. the 10k ohm meter range is not high enough.
Date published: 2012-07-12
Rated 2 out of 5 by from CAL error code I have a old 902 TRUE RMS Fluke meter, and when I open it a CAL code appear. Probably need to be calibrated.Do you have a solution to reset this code erraor?
Date published: 2025-03-26
Rated 2 out of 5 by from Multiple issues with Amp Clamp I'm on my 2nd 902 now and this is the second one to have issues reading amperage. I have to open and close the clamp several time to get a reading which at that point I no longer trust what I'm seeing. Other than that it works fine but thats the main feature for these style of meters. Likely won't purchase another 902.
Date published: 2017-10-19
Rated 2 out of 5 by from Can't test a 10K sensor! How do we call a meter an HVAC meter when we can't test a 10,000 ohm sensor the most common HVAC control sensor?
Date published: 2013-01-18
Rated 1 out of 5 by from Disappointed Bought this meter a few months ago, decided to go this route after having the same common problem with the UEI G2 phoenix of the screen glitching. The fluke 902 does not read DC millivolts which I find goes against it advertising as a HVAC meter. As well, it won’t read high resistance properly. I tried testing varistors with it and it will not register. Pull out the UEI and although the screen will periodically glitch, it properly reads resistance. I also don’t like that the beep on resistance is not able to be muted. Considering the cost of this meter, my expectations were much higher.
Date published: 2022-03-06
Rated 1 out of 5 by from Calibration? Calibration Information manual contains no calibration information other than "return to Fluke". I did not spend $22,000 for my 5500A's so that I could do performance tests! Return to Fluke? A Clamp Meter is now proprietary? Come on, guys! As a calibration service provider, I won't recommend products to my customers unless I can service them. The guys that use these meters need them serviced on-site and are not likely to send them out for certification.
Date published: 2013-03-27
  • y_2026, m_9, d_22, h_11
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.48
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_28
  • loc_en_US, sid_fluke-902, prod, sort_[SortEntry(order=RATING, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.62ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat