Fluke 902 FC True-RMS HVAC Clamp Meter

Fluke 902 FC True-RMS HVAC Clamp Meter is rated 4.8 out of 5 by 16.
  • y_2018, m_12, d_4, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.9
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_16
  • loc_en_US, sid_fluke-902-fc, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 29.18ms
  • REVIEWS, PRODUCT
  • HVAC Clamp Meters | Fluke 902 FC True-RMS HVAC Clamp Meter | Fluke
  • HVAC Clamp Meters | Fluke 902 FC True-RMS HVAC Clamp Meter | Fluke
  • HVAC Clamp Meters | Fluke 902 FC True-RMS HVAC Clamp Meter | Fluke
  • HVAC Clamp Meters | Fluke 902 FC True-RMS HVAC Clamp Meter | Fluke

Key features

  • A wireless Fluke Connect®-enabled clamp meter designed specifically for the needs of HVAC technicians
  • Offers 200 µA DC current measurements to measure flame rod
  • Extends resistance range to measure thermistors up to 60kΩ
  • Captures flue gas temperature
  • Measures start and run motor capacitors
  • Measures variable frequency drive performance

Product overview: Fluke 902 FC True-RMS HVAC Clamp Meter

Fluke 902 FC True-RMS HVAC Clamp Meter helps HVAC technicians work more efficiently on the work site.

The Fluke 902 FC Clamp Meter, with Fluke Connect wireless connectivity, can help HVAC technicians improve productivity in the field. The rugged dual-rated CAT III 600 V, CAT IV 300 V meter equips you to perform many essential HVAC system measurements: microamps for testing pilot light sensors; resistance up to 60 kΩ; AC current and AC/DC voltage; capacitance; and contact temperature, all with just one tool. Plus its small form factor makes it easy to hang on to and navigate in tight work spaces.

Part of the Fluke Connect wireless family

As part of the Fluke Connect family, the 902 FC can transmit measurements to a smartphone or tablet for later, detailed analysis. No need to write down the results. Trend and monitor measurements live on your phone screen, and upload those measurements to the cloud. Combine measurement data from multiple Fluke Connect test tools to create and share reports from the job site via email, and collaborate in real time with other colleagues with ShareLive™ video calls or email.

The 902 FC can also decrease the frequency of wearing personal protective equipment (PPE) when working on high voltage/current panels. Simply turn off the panel. Verify that it is de-energized using standard safety procedures. Place the clamp and synch it to a smartphone. Close the panel, reenergize it, and take measurements from a safe distance.

Other useful features:

  • Ergonomic design fits in your hand and can be used while wearing personal protective equipment
  • Large, easy-to-read backlit display improves readings in low light settings
  • Comes with a TPAK magnetic hanging strap, batteries soft carrying case, and three-year warrant
  • Connects to your smartphone via Fluke Connect so you can read measurements at a safer distance
  • Measures AC current to 600 A and AC and DC voltage to 600 V
  • Measures capacitance to 1000 µF and DC current to 200 µA
  • Measures temperature from -10 °C to 400 °C (14 °F to 752 °F)
  • Offers True-RMS voltage and current measurements to accurately measure non-linear signals
  • Measures resistance to 60 kΩ
  • Offers Min/Max recording to capture variations automatically
  • Runs on two AA alkaline batteries

Specifications: Fluke 902 FC True-RMS HVAC Clamp Meter

Function
A ac (via Jaw)
Resolution0.01/0.1 A
Accuracy2.0% ±5 digit (45-65 Hz)
2.5% ±5 digit (65-400 Hz)
Range60.00/600.0 A
Crest Factor (50Hz or 60Hz)2.5 [email protected] A
3.0 [email protected] A
> 1.4 [email protected] A
Add 2% for CF>400 A
V ac
Resolution0.1 V
Accuracy1.5% ±5 digits
Range600.0 V
V dc
Resolution0.1 V
Accuracy1.5% ±5 digits
Range600.0 V
Ohms
Resolution0.1/1/10
Accuracy1% ±5 digits
Range600/6000/60.00 kΩ
Capacitance
Resolution0.1/1 µF
Accuracy1% ±4 digits
Range100.0/1000 µF
µA
Resolution0.1 µA
Accuracy1% ±5 digits
Range200 µA
Contact temperature
Resolution0.1 C/F
Accuracy1% ±8 digits
Range-40 to 400 °C (-40 °F to 752 °F)
Continuity beeper
Beeper volume75 dBA nom. 15 cm. from case front
On threshold<=30 Ω
Mechanical and General Specifications
Maximum voltage between any terminal and earth ground1000 V
Battery type2 AA alkaline batteries, NEDA 15A, IEC LR6
TemperatureOperating: -10 °C to +50 °C (14 °F to +122 °F)
Storage: -40 °C to +60 °C (-40 °F to +140 °F)
Operating humidityNon condensing (< 10 °C [50 °F]), ≤90 % RH (at 10 °C to 30 °C [50 °F to 86 °F]), ≤75 % RH (at 30 °C to 40 °C (86 °F to 104 °F)), ≤45 % RH (at 40 °C to 50 °C (104 °F to 122 °F))
AltitudeOperating: 3,000 m (9,842 ft)
Storage: 12,000 m (39,370 ft)
Dimensions230 x 83.7 x 45.4mm (9.06 x 3.30 x 1.39 in)
Weight (meter only)419 g (15 oz)
SafetyIEC 61010-1, Pollution Degree 2
IEC 61010-2-032: CAT III 1000 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1000 V / CAT IV 600 V
IP RatingIEC 60529: IP30, non-operating
Radio Frequency CertificationFCC ID:T68-FBLE IC:6627A-FBLE
Electromagnetic Compatibility (EMC)International: IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Korea (KCC): Class A Equipment (Industrial Broadcasting & Communication Equipment) USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Temperature coefficientsAdd 0.1 × specified accuracy for each degree C above 28 °C or below 18 °C

Models: Fluke 902 FC True-RMS HVAC Clamp Meter

FLK-902 FC
Fluke 902 FC True-rms HVAC Clamp Meter

Includes:

  • TL75 test leads (1 pair)
  • 80BK integrated DMM temperature probe (1)
  • AA alkaline batteries (2)
  • Soft carrying case
  • User's manual
  • Statement of calibration

Reviews: Fluke 902 FC True-RMS HVAC Clamp Meter

Rated 5 out of 5 by from Best meter I have owned so far! I purchased my fluke 902fc about 3 months ago and am extremely pleased with its performance and features. I am a commercial HVAC technician and use this meter on a daily basis. Has alll the needed ranges and setting for the HVAC trade! Lots the ability to test flame sensors and lots the Bluetooth fluke connect feature as well!
Date published: 2018-10-30
Rated 4 out of 5 by from Reliable Fluke Quality I have been using my new 902FC TRMS Clamp Meter as a service technician in the HVAC field for about a month now in mostly residential applications. I bought this meter primarily for the wireless technology provided by Fluke Connect. I use it mainly for measuring current but have used the temperature probe once or twice and maybe even the test leads for a voltage measurement or two. I intended it to be used as a standalone tool with one purpose: to wirelessly transmit changes in current that correspond to changes with the load on the system and I must say, this meter excels at the purpose I gave it. However, you'll notice I call this meter the 902FC TRMS Clamp Meter because I do not consider it an HVAC meter due to the current resolution. If I can't measure current down to the hundredths of an amp, I cannot use this meter to accurately determine whether a draft motor on a gas furnace is within specification. If that draft motor is supposed to be pulling .65A and my meter tells me .6A I don't have the right tool for the job. A lot of people have told me, "you're trying to get too specific" and I get where that's coming from, I simply do not agree because it is my job to be as specific and precise as possible. I bought this Fluke meter because I knew I could use it with confidence and I will continue to buy Fluke products for that reason, however a meter marketed as an "HVAC" meter that lacks a potentially crucial feature can dishearten even the most loyal of customers, one might even feel misled. If it weren't for my trust in the product Fluke generates with reliability, accuracy and innovations like Fluke Connect...I would have returned the meter solely on those grounds. This meter works just as hard as I do and I have never had a problem with any of my Fluke products in the sun, rain, ice or snow. I understand that motors with such small amp specifications are probably not the norm for most technicians out there but I know that this is a feature most technicians would appreciate if they're serious about their job. So, now that I have said what I needed to say I would like to address my audience directly in a very concise manner allowing you to ignore everything I've just said. To Potential Customers: Yes, absolutely buy this meter! Just know that as it currently stands, you won't be able to measure current down to the hundredths of an amp. To Fluke: Please incorporate .01 resolution into the 902FC TRMS Clamp Meter, honestly I am totally willing to buy another if you do! It would give me great confidance in the company to see that as opposed to say, just taking "HVAC" out of the meter's name.
Date published: 2018-04-19
Rated 5 out of 5 by from The best HVAC amp clamp yet I work in HVAC and want my customers to get the best possible service from me, that is why I choose Fluke over the others. Accuracy means so much to me and when you compare the 902 FC to other meters on the market you can see why I made this purchase. The 902 was a good meter the 902 FC is better for me personally. Pros The smaller size is nice and fits better in tighter access points. The dial now has a positive click feel versus the old 902. Fluke Connect Fluke product dependability/longevity Safety Cons Auto time off requires you to switch the dial to off then to the desired selection versus just moving the dial one click to another section then back saving time. Hanging kit not included Would be nice to have a probe clip or holder on clamp Clamp is wide but no wider than other Fluke Amp Clamps. As you can see the cons are insignificant to the value you get with the Pros. To me saving my customers money and time are critical. The one or more percent accuracy to me is why I choose Fluke.
Date published: 2016-12-12
Rated 5 out of 5 by from Excellent product Bought this a few weeks ago and absolutely love it. Really love the Bluetooth feature.
Date published: 2016-12-10
Rated 5 out of 5 by from Great Meter I work residential HVAC and this truly is the perfect meter. This meets all my needs and with the higher ohm range I can diagnose the most advanced equipment. Very happy with my purchase.
Date published: 2016-12-09
Rated 5 out of 5 by from very durable! I purchased this meter last month, and I am extremely impressed. It is a huge improvement of my old equipment. I use it on a daily basis, in harsh conditions, and it has yet to let me down!
Date published: 2016-12-09
Rated 4 out of 5 by from Wireless Bluetooth Readings Phone app work well with this bluetooth amp probe if you are close to the unit.
Date published: 2016-12-08
Rated 5 out of 5 by from Fluke Dependability with Wireless Connectivity I've had this meter for a few months now and love it. Being able to connect the clamp and get a true amp reading on an HVAC motor with the door on the equipment is invaluable in troubleshooting all types of equipment. I also like that with the connect app, I can watch the graph in real time and my employees can also share real time data with me from anywhere. That alone has saved countless hours of windshield time for me.
Date published: 2016-12-08
  • y_2018, m_12, d_4, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.9
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_16
  • loc_en_US, sid_fluke-902-fc, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 43.73ms
  • REVIEWS, PRODUCT