Fluke 718 Pressure Calibrator

  • Fluke 718 Pressure Calibrator | Fluke

Key features

  • Pressure Source and Milliamp Measurement to calibrate and maintain almost any pressure device
  • Integrated pump is easily cleaned when accidently exposed to fluids that reduces cost of ownership and repairs and enables servicing the pump in the field
  • Error % calculation for quicker pass/fail decision making in the field
  • Best in class mA accuracy of 0.015% for better measurement confidence and workload coverage
  • Min/Max/Hold to capture changing measurements
  • Switch test feature for quicker and more accurate pressure switch testing
  • New 1 and 300 psi pressure ranges mean fewer extra tools required
  • 1, 30, 100 & 300 psi ranges now available
Fluke 718 Pressure Calibrator is rated 4.0 out of 5 by 1.
  • y_2018, m_8, d_11, h_23
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_fluke-718, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 25.86ms
  • REVIEWS, PRODUCT
Get a free demo

Product overview

The complete solution to pressure calibration

The Fluke 718 Pressure Calibrator provides a total pressure calibration solution for transmitters, gauges and switches. This compact pressure calibration solution is about a third of the size of comparable instruments and weighs just one kilogram (two pounds). The unique easy to clean pump helps protect the pump from damage and provides the ability to service the pump without disassembly, even in the field.

Models

Fluke 718 1G
Fluke 718 1G Pressure Calibrator
-1 to 1 psi, (-68.9 mbar to 68.9 mbar, -6.89 to 6.89 kPa)

Includes:

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
Fluke 718 30G
Fluke 718 30G Pressure Calibrator
-12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)

Includes:

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
Fluke 718 100G
Fluke 718 100G Pressure Calibrator
-12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)

Includes:

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data
Fluke 718 300G
Fluke 718 300G Pressure Calibrator
-12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa )

Includes:

  • Protective Yellow Holster with test lead storage
  • Instructions Sheet (14 languages)
  • Test Leads and Alligator Clip
  • Two 9V alkaline batteries
  • NIST - Traceable calibration report and data

Specifications

Technical Specifications
Fluke 718 Series
Measure pressure(Internal sensor)
Accuracy0.025% full scale
FunctionsZero, min/max, hold, damp
Dry air, non-corrosives only
Fluke 718 1G
Range-1 psi to +1 psi, -68.9 mbar to 68.9 mbar (-6.89 kPa to 6.89 kPa)
Resolution0.0001 psi, 0.001 mbar, 0.0001 kPa
Over pressure5x Full Scale
FunctionsZero, Min, Max, Hold, Damp
Fluke 718 30G
Range-12 psi to 30 psi, (-850 mbar to 2 bar, -85 to 206.84 kPa)
Resolution0.001 psi, 0.1 mbar, 0.01 kPa
Over pressure5x Full Scale
FunctionsZero, Min, Max, Hold, Damp
Fluke 718 100G
Range-12 psi to 100 psi, (-850 mbar to 7 bar, -85 to 689.48 kPa)
Resolution0.01 psi, 0.1 mbar, 0.01 kPa
Over pressure2x Full Scale
FunctionsZero, Min, Max, Hold, Damp
Fluke 718 300G
Range-12 psi to 300 psi, (-850 mbar to 20 bar, -85 to 2068.42 kPa)
Resolution0.01 psi, 1 mbar, 0.1 kPa
Over pressure375 psi 25 bar
FunctionsZero, Min, Max, Hold, Damp
Fluke 718 series via 700 Series Pressure Modules
Range29 pressure modules, 0 – 1 inH20 to 10,000 psi, 2.5 mbar to 700 bar. Over pressure per pressure module specs
ResolutionPer pressure module specs
AccuracyTo 0.025% of full span, per pressure module specs
FunctionsZero, Min, Max, Hold, Damp
Media compatibility per pressure module specs
Fluke 718 Series Via Built in Pump
Range-12 psi or -850 mbar to full scale Supported Pressure Units; psi, inH20 (4°C), inH20 (20°C), cmH20 (4°C), cmH20 (20°C), bar, mbar, kPa, inHg, mmHg, kg/cm
Loop power range24 V DC
Accuracy±10%
Drive; 20 mA into 1000 Ω for battery > 6.8 V; 700 Ω for battery 5.8 to 6.8 V
mA Measure
Range0 mA to 24 mA
Resolution0.001 mA
Accuracy0.015% + 1 count
General Specifications
Maximum voltage30 volts (non-operating)
Temperature-40°C to 60°C
Operating temperature-10°C to 55°C
Relative humidity95% (10°C to 30°C); 75% (30°C to 40°C); 45% (40°C to 50°C); 35% (50°C to 55°C)
Operating altitude3,000 M max
Shock1 M drop test
VibrationRandom, 2 g, 5 Hz – 500 Hz
SafetyCSA C22.2 No. 1010.1: 1992
EMCEN50082-1: 1992 and EN55022: 1994 Class B
Size216 x 94 x 66 mm (8.50 x 3.72 x 2.60 in)
Weight992 g (35 oz)
Power, battery life9V battery ANSI/NEDA 1604A or IEC 6LR619V alkaline; two batteries in 718
Battery life4 to 20 hours typical, depending on functions used
WarrantyThree years (one year on pressure pump in Fluke 718)
DisplayLCD, 5 digit pressure and current simultaneous
For use with non-corrosive gasses

Resources

Rated 4 out of 5 by from Great product, with a minor quality control issue When I took this out of the sleeve I noticed the gasket was pinched in the case and the set screw on the pump knob had fallen out. It wasn't a big deal, but shouldn't have happened on a quality tool. Functionally, this works great. The manual pressure vacuum pump is adequate for what we need. I wish they had a hard case option for this. Instead I bought a Pelican Case 1200, which was a snug fit. The next size larger would have been nice to provide room for accessories.
Date published: 2016-12-08
  • y_2018, m_8, d_11, h_23
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_en_US, sid_fluke-718, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 27.22ms
  • REVIEWS, PRODUCT