Key features

  • Complete pressure, temperature, and mA loop calibrator
  • Troubleshoot and calibrate HART smart digital transmitters
  • Create calibration procedures and automatically document results
  • Connect to calibration management software

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
$10,939.99
FREE Shipping
30-day Returns
Product + Premium Care Plan
Premium Care Plan only (I already own the product)
No thanks

Product overview: Fluke 754 Documenting Process Calibrator-HART

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

All-in-One Multi-Function Calibrator for Process Professionals

Maximize your investment with the Fluke 754 Documenting Process Calibrator-HART—a portable, rugged, and versatile calibrator trusted by professionals worldwide. Whether you’re calibrating instruments, troubleshooting, or performing routine maintenance, the Fluke 754 helps you work faster and more efficiently.

Why Choose the Fluke 754?

  • Multi-function capability: Source, simulate, and measure pressure, temperature, and electrical signals—all in one handheld tool.
  • Integrated HART communication: Calibrate and maintain HART smart transmitters and instrumentation without a separate communicator.
  • Bright dual display: View sourced and measured parameters at the same time for faster, error-free work.
  • Long battery life: Rechargeable Li-Ion battery delivers up to 10 hours of operation, plus direct AC power support.
  • Seamless documentation: Automate calibration procedures, store results, and ensure compliance with ISO 9000, FDA, EPA, and OSHA standards.
  • Portable and rugged: Designed for demanding industrial environments.

Key Measurement and Source Capabilities

  • AC/DC voltage
  • mA loop with 24V loop power
  • Pressure (compatible with Fluke 750P Series Pressure Modules)
  • Thermocouples & RTDs
  • Frequency
  • Resistance

Enhanced Process Calibration. Simplified.

The Fluke 754 is more than just a calibrator. Its built-in HART interface lets you perform nearly all digital communicator tasks. Easily handle fast-pulsed RTD transmitters and PLCs, custom auto-step and ramping, custom units, programmable measurement delay, and one- or two-point switch testing—all with one device.

Download procedures, lists, and instructions created in your calibration management software, or upload calibration results for documentation and analysis. The Fluke 754 supports a full week of procedures and is compatible with leading asset management solutions.

Go Paperless with Fluke DPCTrack2 Software

For a seamless, paperless calibration management experience, pair your Fluke 754 Documenting Process Calibrator-HART with Fluke DPCTrack2 Calibration Management Software. Simplify record-keeping, automate procedures, and streamline compliance.

Ready to Work Smarter? Upgrade to the Fluke 754 Today.

Experience the power, precision, and reliability of the Fluke 754 Documenting Process Calibrator-HART—the process industry’s most trusted multi-function calibrator.

What's in the box:

  • Fluke 754 Documenting Process Calibrator-HART
  • BC7240 battery charger
  • Li-on BP7240 battery pack
  • NIST-traceable calibration report and data
  • (3 sets) TP220 test probes
  • (3 sets) "Extended tooth" alligator clips
  • (3 sets) Stackable test leads
  • (2 sets) AC280 hook clips
  • C799 Soft Field Case
  • USB communication cable, Fluke 754HHC HART communications cable
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 754 Documenting Process Calibrator-HART

Measurement Accuracy
Voltage DCRange/ Resolution1 Year2 Years
100.000 mV0.02% + 0.005 mV0.03% + 0.005 mV
3.00000 V0.02% + 0.00005 V0.03% + 0.00005 V
30.0000 V0.02% + 0.0005 V0.03% + 0.0005 V
300.00 V0.05% + 0.05 V0.07% + 0.05 V
Voltage AC3.000 V (40 Hz to 500 Hz) / 0.001 V0.5% + 0.002 V1.0% + 0.004 V
30.00 V (40 Hz to 500 Hz) / 0.01 V0.5% + 0.02 V1.0% + 0.04 V
300.0 V (40 Hz to 500 Hz) / 0.1 V0.5% + 0.2 V1.0% + 0.2 V
Current DC30.000 mA0.01% + 5 uA0.015% + 7 uA
110.00 mA0.01% + 20 uA0.015% + 30 uA
Resistance10.000 Ω0.05% + 50 mΩ0.07% + 70 mΩ
100.00 Ω0.05% + 50 mΩ0.07% + 70 mΩ
1.0000 kΩ0.05% + 500 mΩ0.07% + 0.5 Ω
10.000 kΩ0.1% + 10 Ω0.15% + 15 Ω
Frequency1.00 to 110.00 Hz / 0.01 Hz 0.05 Hz
110.1 to 1100.0 Hz / 0.1 Hz 0.5 Hz
1.101 to 11.000 kHz / 0.001 kHz 0.005 kHz
11.01 to 50.00 kHz / 0.01 kHz 0.05 kHz
Source Accuracy
  1 Year2 Years
Voltage DC100.000 mV0.01% + 0.005 mV0.015% + 0.005 mV
1.00000 V0.01% + 0.00005 V0.015% + 0.0005 V
15.0000 V0.01% + 0.0005 V0.015% + 0.0005 V
Current DC22.000 mA (source)0.01% + 0.003 mA0.02% + 0.003 mA
Current sink (simulate)0.02% + 0.007 mA0.04% + 0.007 mA
Resistance10.000 Ω0.01% + 10 mΩ0.015% + 15 mΩ
100.00 Ω0.01% + 20 mΩ0.015% + 30 mΩ
1.0000 kΩ0.02% + 0.2 Ω0.03% + 0.3 Ω
10.000 kΩ0.02% + 3 Ω0.03% + 5 Ω
Frequency0.1 to 10.99 Hz 0.01 Hz
0.01 to 10.99 Hz 0.01 Hz
11.00 to 109.99 Hz 0.1 Hz
110.0 to 1099.9 Hz 0.1 Hz
1.100 to 21.999 kHz 0.002 kHz
22.000 to 50.000 kHz 0.005 kHz
Technical Data
Data log functionsMeasure functionsVoltage, current, resistance, frequency, temperature, pressure
Reading rate1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length8000 readings (7980 for 30 or 60 readings/minute)
Ramp functionsSource functionsVoltage, current, resistance, frequency, temperature
Rate4 steps/second
Trip detectContinuity or voltage (continuity detection not available when sourcing current)
Loop power functionVoltageSelectable, 26 V
Accuracy10%, 18 V minimum at 22 mA
Maximum current25 mA, short circuit protected
Maximum input voltage50 V DC
Step functionsSource functionsVoltage, current, resistance, frequency, temperature
Manual stepSelectable step, change with arrow buttons
AutostepFully programmable for function, start delay, stepvalue, time per step, repeat
Environmental Specifications
Operating temperature-10°C to +50°C
Storage temperature-20°C to +60°C
Dust/water resistanceMeets IP52, IEC 529
Operating altitude3000 m above mean sea level (9842 ft)
Safety Specifications
Agency approvalsCAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
Mechanical and General Specifications
Size136 x 245 x 63 mm (5.4 x 9.6 x 2.5 in)
Weight1.2 kg (2.7 lb)
BatteriesInternal Battery Pack Li-ion: 7.2V,4400mAh, 30 Wh
Battery life>8 hours typical
Battery replacementReplace without opening calibrator; no tools required
Side port connectionsPressure module connector
USB Connector to interface to your PC
Digital instrument (HART) connector
Connection for optional battery charger/eliminator
Data storage capacity1 week of calibration procedures results
90 day specificationsThe standard specification interval for the 750 Seriesare 1 and 2 years.
Typical 90 day measurement and source accuracy can be estimated by dividing the one year "% of reading" or "% of output" specifications by 2.
Floor specifications, expressed as "% of full scale" or "counts" or "ohms" remain constant.
Temperature, Resistance Temperature Detectors
Degrees or % of reading - Type (α)Range °CMeasure °C1
 1 year2 year
100 Ω Pt (385)-200 to 100
100 to 800
0.07°C
0.02% + 0.05°C
0.14°C
0.04% + 0.10°C
200 Ω Pt (385)-200 to 100
100 to 630
0.07°C
0.02% + 0.05°C
0.14°C
0.04% + 0.10°C
500 Ω Pt (385)-200 to 100
100 to 630
0.07°C
0.02% + 0.05°C
0.14°C
0.04% + 0.10°C
1000 Ω Pt (385)-200 to 100
100 to 630
0.07°C
0.02% + 0.05°C
0.14°C
0.04% + 0.10°C
100 Ω Pt (3916)-200 to 100
100 to 630
0.07°C
0.02% + 0.05°C
0.14°C
0.04% + 0.10°C
100 Ω Pt (3926)-200 to 100
100 to 630
0.08°C
0.02% + 0.06°C
0.16°C
0.04% + 0.12°C
10 Ω Cu (427)-100 to 2600.2°C0.4°C
120 Ω Ni (672)-80 to 2600.1°C0.2°C
Source currentSource °CAllowable current2
 1 year2 year 
1 mA0.05°C
0.0125% + 0.04°C
0.10°C
0.025% + 0.08°C
0.1 mA to 10 mA
500 μA0.06°C
0.017% + 0.05°C
0.12°C
0.034% + 0.10°C
0.1 mA to 1 mA
250 μA0.06°C
0.017% + 0.05°C
0.12°C
0.034% + 0.10°C
0.1 mA to 1 mA
150 μA0.06 C
0.017% + 0.05°C
0.12 C
0.034% + 0.10°C
0.1 mA to 1 mA
1 mA0.05°C
0.0125% + 0.04°C
0.10°C
0.025% + 0.08°C
0.1 mA to 10 mA
1 mA0.05°C
0.0125% + 0.04°C
0.10°C
0.025% + 0.08°C
0.1 mA to 10 mA
3 mA0.2°C0.4°C0.1 mA to 10 mA
1 mA0.04°C0.08°C0.1 mA to 10 mA
1. For two and three-wire RTD measurements, add 0.4°C to the specifications.
2. Supports pulsed transmitters and PLCs with pulse times as short as 1 ms
Temperature, Thermocouples
TypeSource °CMeasure °CSource °C
  1 year2 years1 year2 years
E-250 to -2001.32.00.60.9
-200 to -1000.50.80.30.4
-100 to 6000.30.40.30.4
600 to 10000.40.60.20.3
N-200 to -1001.01.50.60.9
-100 to 9000.50.80.50.8
900 to 13000.60.90.30.4
J-210 to -1000.60.90.30.4
-100 to 8000.30.40.20.3
800 to 12000.50.80.30.3
K-200 to -1000.71.00.40.6
-100 to 4000.30.40.30.4
400 to 12000.50.80.30.4
1200 to 13720.71.00.30.4
T-250 to -2001.72.50.91.4
-200 to 00.60.90.40.6
0 to 4000.30.40.30.4
B600 to 8001.32.01.01.5
800 to 10001.01.50.81.2
1000 to 18200.91.30.81.2
R-20 to 02.32.81.21.8
0 to 1001.52.21.11.7
100 to 17671.01.50.91.4
S-20 to 02.32.81.21.8
0 to 2001.52.11.11.7
200 to 14000.91.40.91.4
1400 to 17671.11.71.01.5
C0 to 8000.60.90.60.9
800 to 12000.81.20.71.0
1200 to 18001.11.60.91.4
1800 to 23162.03.01.32.0
L-200 to -1000.60.90.30.4
-100 to 8000.30.40.20.3
800 to 9000.50.80.20.3
U-200 to 00.60.90.40.6
0 to 6000.30.40.30.4
BP0 to 10001.01.50.40.6
1000 to 20001.62.40.60.9
2000 to 25002.03.00.81.2
XK-200 to 3000.20.30.20.5
300 to 8000.40.60.30.6

Models: Fluke 754 Documenting Process Calibrator-HART

Fluke 754

Fluke 754 Documenting Process Calibrator-HART

Part#: 3405771
UPC#: 0 95969 49175 4

Includes:

  • BC7240 battery charger
  • Li-on BP7240 battery pack
  • DPCTrack 2™ Sample Software
  • Instruction manual
  • NIST-traceable calibration report and data
  • Three sets of TP220 test probes
  • Three sets of "extended tooth" alligator clips
  • Three sets stackable test leads
  • Two sets AC280 hook clips
  • C799 Soft Field Case
  • USB communication cable, Fluke 754HHC HART communications cable
FPC1S-FLUKE75X-1

Premium Care 1-Year Standard Plan for Fluke 754 and 753

Part#: 5575064

Includes:

  • Premium Care 1-Year Standard Plan
FPC3S-FLUKE75X-1

Premium Care 3-Year Standard Plan for Fluke 754 and 753

Part#: 5575073

Includes:

  • Premium Care 3-Year Standard Plan
FLUKE-754/FPC

Fluke 754 Bundled with Premium Care 1-Year Standard Plan

Part#: 5575360

Includes:

  • Premium Care 1-Year Standard Plan
  • Fluke 754
  • BC7240 battery charger
  • Li-on BP7240 battery pack
  • DPCTrack 2™️ Sample Software
  • Instruction manual
  • NIST-traceable calibration report and data
  • Three sets of TP220 test probes with three sets of "extended tooth" alligator clips
  • Two sets AC280 hook clips
  • C799 Soft Field Case
  • USB communication cable, Fluke 754HHC HART communications cable
Fluke 754 Documenting Process Calibrator-HART is rated 3.9 out of 5 by 15.
Rated 2 out of 5 by from nice all in one unit I bought this unit 2 weeks ago and went to use it as a hart communicator and noticed it does not support my new yokogawa yta and eja transmitters. It supports versions 5.1 and 5.2 but not rev. 5.3.11. I am disapointed in this meter as a hart communicator. I hope I can get updates for the hart DDE's that I need before my to projects start.
Date published: 2013-12-18
Rated 3 out of 5 by from Won't provide bias power for a 24Vdc, three-wire 4-20mA sensor For $7000, I expected the world. I got all one could ask for... but for the little island I really needed. I wanted this unit to provide about 35mA of power to the +24V bias of my three-wire sensor and measure the 4-20mA output. No dice. It will do 2-wire loop power all day, alas, not three-wire. So, I'm stuck carrying around a 24V supply to power my sensor while the 754 meter reads the 4-20. I should have just bought a Hart Communicator for half the price and got a Fluke 789 for $900. The Fluke tech support said "This is the first time anybody asked for this feature." Really?
Date published: 2013-09-10
Rated 2 out of 5 by from Very limited HART functionality. Can't update or load "HART Device Descriptors" which means very limited HART functionality. Do not make the mistake of thinking that you can substitute the Fluke 754 for a HART communicator. For many devices, you will need to bring the calibrator AND a real HART communicator to calibrate the instrument. There are modern times and I feel that Fluke really dropped the ball here.
Date published: 2013-05-01
Rated 3 out of 5 by from Good but the HART needs work I convinced my boss to buy this over an emmerson communicator. Come to find out it does not support all specific device DD's. The first instrument I used it on it communicated HART fine but could not display all the DD parameters. I called support and was told that when a firmware upgrade came out it might support more HART DD's but they didn't know if/when this would happen. Had to use an Emmerson communicator after all. As far as a calibrator its great. The pressure modules and hand pump are great. The DPCTrack2 software is good to keep track of everything. Dont plan on replacing a communicator with this one instrument though.
Date published: 2012-12-13
Rated 5 out of 5 by from This does everything the 744 did; BETTER and LONGER! For well over a dozen years I have used the 744 and when I heard news about the impending launch of the 754 I was salivating like Pavlov's Dogs in anticipation! We have hundreds of 744s throughout all of our divisions and we are already over a dozen 754s. The advances you have made in the legibility of the display out in varying light conditions and the battery life are worth the cost of admission alone. You have gone well beyond there with increased precision and reliability, and now the HART works with all the Rosemount Transmitters; I'd say you not only hit a homer, but hit a grand slam!
Date published: 2012-06-13
Rated 5 out of 5 by from This is what i expected from fluke great new color display! extra features that the 744 doesnt have are a plus......just what I needed to upgrade!
Date published: 2012-06-08
Rated 5 out of 5 by from Very easy to use I have been using this meter to calibrate everyday for several weeks now and it definitely delivers, it's a huge time saver, well designed, simple to operate, and well worth the investment.
Date published: 2012-06-08
  • y_2025, m_7, d_16, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_15
  • loc_en_US, sid_3739311570996, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 24.3ms
  • REVIEWS, PRODUCT
Rated 2 out of 5 by from nice all in one unit I bought this unit 2 weeks ago and went to use it as a hart communicator and noticed it does not support my new yokogawa yta and eja transmitters. It supports versions 5.1 and 5.2 but not rev. 5.3.11. I am disapointed in this meter as a hart communicator. I hope I can get updates for the hart DDE's that I need before my to projects start.
Date published: 2013-12-18
Rated 3 out of 5 by from Won't provide bias power for a 24Vdc, three-wire 4-20mA sensor For $7000, I expected the world. I got all one could ask for... but for the little island I really needed. I wanted this unit to provide about 35mA of power to the +24V bias of my three-wire sensor and measure the 4-20mA output. No dice. It will do 2-wire loop power all day, alas, not three-wire. So, I'm stuck carrying around a 24V supply to power my sensor while the 754 meter reads the 4-20. I should have just bought a Hart Communicator for half the price and got a Fluke 789 for $900. The Fluke tech support said "This is the first time anybody asked for this feature." Really?
Date published: 2013-09-10
Rated 2 out of 5 by from Very limited HART functionality. Can't update or load "HART Device Descriptors" which means very limited HART functionality. Do not make the mistake of thinking that you can substitute the Fluke 754 for a HART communicator. For many devices, you will need to bring the calibrator AND a real HART communicator to calibrate the instrument. There are modern times and I feel that Fluke really dropped the ball here.
Date published: 2013-05-01
Rated 3 out of 5 by from Good but the HART needs work I convinced my boss to buy this over an emmerson communicator. Come to find out it does not support all specific device DD's. The first instrument I used it on it communicated HART fine but could not display all the DD parameters. I called support and was told that when a firmware upgrade came out it might support more HART DD's but they didn't know if/when this would happen. Had to use an Emmerson communicator after all. As far as a calibrator its great. The pressure modules and hand pump are great. The DPCTrack2 software is good to keep track of everything. Dont plan on replacing a communicator with this one instrument though.
Date published: 2012-12-13
Rated 5 out of 5 by from This does everything the 744 did; BETTER and LONGER! For well over a dozen years I have used the 744 and when I heard news about the impending launch of the 754 I was salivating like Pavlov's Dogs in anticipation! We have hundreds of 744s throughout all of our divisions and we are already over a dozen 754s. The advances you have made in the legibility of the display out in varying light conditions and the battery life are worth the cost of admission alone. You have gone well beyond there with increased precision and reliability, and now the HART works with all the Rosemount Transmitters; I'd say you not only hit a homer, but hit a grand slam!
Date published: 2012-06-13
Rated 5 out of 5 by from This is what i expected from fluke great new color display! extra features that the 744 doesnt have are a plus......just what I needed to upgrade!
Date published: 2012-06-08
Rated 5 out of 5 by from Very easy to use I have been using this meter to calibrate everyday for several weeks now and it definitely delivers, it's a huge time saver, well designed, simple to operate, and well worth the investment.
Date published: 2012-06-08
  • y_2025, m_7, d_16, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_2, bvpage2n
  • co_hasreviews, tv_0, tr_15
  • loc_en_US, sid_3739311570996, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.39ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat