Navigating the Future with eMobility Solutions: Ensuring Reliability and Safety
By Theo Brillhart, Fluke Engineering
As the world transitions toward sustainable energy and transportation, eMobility solutions are at the forefront of the transformation. Electric Vehicles (EVs) and their corresponding infrastructure are becoming more prevalent, heralding a future where clean energy powers our movement.

However, the shift to eMobility is not without its challenges. Ensuring the reliability, safety, and efficiency of Electric Vehicle Supply Equipment (EVSE) is paramount, and Fluke is leading the way with state-of-the-art testing and measurement solutions.
What Are eMobility Solutions?
eMobility solutions encompass a range of technologies and services designed to support the use and development of EVs and their infrastructure. These solutions include EVs, charging stations, EV battery technology, and the software and hardware systems needed to manage and maintain the vehicles. The primary goal of eMobility solutions is to facilitate the transition from traditional fossil fuel-powered vehicles to cleaner, more sustainable electric alternatives.
Understanding eMobility Solutions
To fully grasp the potential and challenges of eMobility, it's essential to first understand its core components. eMobility solutions encompass a variety of technologies and services, each playing a critical role in the transition to electric transportation.
Components of eMobility Solutions
- Electric Vehicles (EVs)
- Battery Electric Vehicles (BEVs) are powered entirely by electricity stored in batteries.
- Plug-in Hybrid Electric Vehicles (PHEVs) combine an electric motor with a traditional internal combustion engine, and they are rechargeable via external power sources.
- Hybrid Electric Vehicles (HEVs) use both an internal combustion engine and electric power, but they cannot be plugged in for charging.
- Charging Infrastructure
- Public charging stations are installed in public areas such as parking lots and streets.
- Private charging solutions are located at homes or workplaces.
- Level 2 charging stations use alternating current (AC) and charge faster than residential stations but slower than Fast DC.
- Fast charging stations provide high-power DC charging that significantly reduces charging time.
- Battery Technology
- Lithium-ion batteries are commonly used in EVs due to their high energy density and efficiency.
- Solid-state batteries are an emerging technology with higher energy density and improved safety.
- Battery Management Systems (BMS) ensure manage the health and performance of batteries.
- Energy Management
- Smart grids integrate EV charging with renewable energy sources.
- Vehicle-to-Grid (V2G) technology allows EVs to return excess electricity to the grid.
- Software Solutions
- Fleet management systems optimize the operation of electric vehicle fleets.
- Navigation and charging apps help drivers locate charging stations, plan routes, and pay for charging services.
Importance of Testing
With the growing complexity of eMobility solutions, proper testing has never been more important. Testing ensures that all components of EV infrastructure operate safely, reliably, and efficiently. Regular testing and maintenance can prevent failures, reduce downtime, and enhance the lifespan of EV charging equipment.
Testing involves verifying the correct operation of EVSE, ensuring compliance with safety standards, and promptly diagnosing and resolving issues. This is where expertise and advanced testing tools come into play.
Fluke eMobility Equipment and Solutions
Fluke offers a comprehensive range of tools designed to meet the testing needs of the eMobility sector. Our equipment helps to ensures the safety, reliability, and performance of EV infrastructure.
Fluke FEV100
The Fluke FEV100 is a specialized charging station test adapter that simulates the presence of an EV. This allows technicians to test the functionality and safety of charging stations without needing an actual EV or opening the EVSE cabinet. Key features of the FEV100 include:
- Simulation of EV Connection: Emulate the connection between the EV and the charging station.
- Functional Testing: Enable testing of various charging modes and safety checks.
- Diagnostic LEDs: Indicate the status of the charging station, including power and error states.
Fluke FEV150
Building on the capabilities of the FEV100, the Fluke FEV150 offers advanced simulation and comprehensive testing features. It allows for detailed performance evaluations, including checking output voltage, available current, and power. The FEV150 also supports data logging and report generation, making it an invaluable tool for compliance and documentation.
Other Essential Fluke Tools
- Multimeters
- Fluke 87V: Known for precision and reliability in complex electrical systems.
- Fluke 177 True-RMS Digital Multimeter: Accurate readings in noisy environments, essential for power electronics in EVs and charging stations.
- Insulation Testers
- Fluke 1555 FC: Tests high-voltage equipment insulation, ensuring safety and reliability.
- Fluke 1587 FC: Combines a digital insulation tester with a multimeter for versatile use.
- Thermal Imaging Cameras
- Fluke Ti480 PRO: Detects overheating components in EV charging stations and battery systems.
- Fluke Tis20+: Identifies hot spots and potential issues in electrical connections.
- Battery Analyzers
- Fluke 500 Series: Measures voltage, resistance, and conductance for comprehensive battery assessments.
- Portable Oscilloscopes
- Fluke 190 ScopeMeter®: Analyze control pilot signal waveforms to ensure proper communication between the EV and the charger.
- Power Quality Analyzers
- Fluke 1770 Series Three-Phase Power Quality Analyzer: Identifies power quality issues affecting EV charging station performance.
- Fluke 1748 Power Quality Logger: Logs and analyzes power quality to ensure infrastructure compliance.
Benefits of eMobility
- Environmental Impact: One of the most significant benefits of eMobility is its positive environmental impact. Electric vehicles produce no tailpipe emissions, reducing air pollution and greenhouse gas emissions. This contributes to cleaner air and reduces the vehicle’s overall carbon footprint.
- Economic Advantages: Electric vehicles offer potential long-term cost savings. Although the initial investment for an EV may be higher than that for a traditional vehicle, EVs typically have lower operating and maintenance costs. Additionally, governments worldwide offer incentives, rebates, and subsidies to encourage the adoption of electric vehicles.
- Energy Efficiency: Electric motors are more efficient than internal combustion engines, converting a higher percentage of energy from the battery into movement. This efficiency translates into lower energy consumption and better overall performance.
- Innovation and Job Creation: The growth of the eMobility sector is driving innovation and creating new business opportunities. From manufacturing and installing charging infrastructure to developing advanced battery technologies, eMobility generates jobs and fosters economic growth.
- Enhanced User Experience: Electric vehicles offer a quieter, smoother driving experience with instant torque and acceleration. Additionally, the convenience of charging at home or work eliminates the need for frequent trips to the gas station.
Key Learnings
The transition to eMobility is reshaping the transportation landscape, offering significant environmental, economic, and societal benefits. However, ensuring the reliability, safety, and efficiency of eMobility solutions is crucial for their successful adoption.
With its advanced testing and measurement tools, Fluke plays a vital role in this transition. The Fluke FEV100 and FEV150, along with their range of multimeters, insulation testers, thermal imaging cameras, battery analyzers, and power quality analyzers, provide comprehensive solutions for installing, commissioning, maintaining, and troubleshooting EV infrastructure.
By leveraging Fluke's expertise and innovative tools, technicians and engineers can ensure that eMobility solutions operate at their best, driving the world toward a cleaner, more sustainable future.
Unlocking a Better Future
As the world embraces the shift to electric vehicles, the need for reliable and safe eMobility solutions becomes increasingly important. At Fluke, our extensive range of testing and measurement tools is essential for maintaining the performance and safety of EV infrastructure. By understanding and utilizing these tools, we can help ensure a seamless transition to a more sustainable transportation system, paving the way for a cleaner, greener future.