English

Fluke 1507 Insulation Resistance Tester

Model#: Fluke 1507 Part#: 5066006 UPC#: 0 95969 28867 5
Fluke 1507 Insulation Resistance Tester is rated 4.7 out of 5 by 19.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.23ms
  • REVIEWS, PRODUCT
  • Fluke 1507 Insulation Resistance Tester
  • Fluke 1507 Insulation Resistance Tester

Key features

  • Rugged, compact advanced insulation resistance tester for electrical contractors and industrial and commercial electricians
  • Automatically calculates Polarization Index and Dielectric Absorption Ratio
  • Makes repetitive tests simple and easy with a Compare (Pass/Fail) function 
  • Offers multiple insulation test voltages: 50 V, 100 V, 250 V, 500 V, and 1000 V
In stock
$856.99
FREE Shipping
30-day Returns

Product overview: Fluke 1507 Insulation Resistance Tester

The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.

Take advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.

Other useful capabilities:

  • Performs insulation tests from 0.01 MΩ to 10 GΩ
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Includes auto-discharge of capacitive voltage for added user protection
  • Measures AC/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ
  • Provides lo-ohms earth-bond continuity (200 mA)
  • Simplifies repetitive or hard-to-reach testing with the remote test probe
  • Saves battery power with auto power off
  • Presents results on a large, backlit display
  • Features CAT IV 600 V overvoltage category rating
  • Comes with remote probe, test leads, test probes, alligator clips and one-year warranty
  • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
  • Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests

Useful resources and rugged tools for Solar professionals

What's in the box:

  • Fluke 1507 Insulation Resistance Tester
  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation

Specifications: Fluke 1507 Insulation Resistance Tester

AC/DC Voltage Measurement
AccuracyRange600.0 V
Resolution0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits)±(2% + 3)
Input impedance3 MΩ (nominal), < 100 pF
Common mode rejection ratio (1 kΩ unbalanced):> 60 dB at DC, 50 or 60 Hz
Overload protection600 V rms or DC
Earth Bond Resistance Measurement
Range/Resolution20.00 Ω0.01 Ω
200.0 Ω0.1 Ω
2000 Ω1.0 Ω
20.00 kΩ0.01 kΩ
Accuracy±(1.5% + 3)
Overload protection2 V rms or DC
Open circuit test voltage> 4.0 V, < 8 V
Short circuit current> 200.0 mA
Insulation Specifications
Measurement range0.01 MΩ to 10 GΩ
Test voltage50 V, 100 V, 250 V, 500 V, 1000 V
Test voltage accuracy+ 20%, - 0%
Short circuit current1 mA nominal
Auto dischargeDischarge time < 0.5 second for C = 1 µF or less
Live circuit indicatorInhibit test if terminal voltage > 30 V prior to initialization of test
Maximum capacitive loadOperable with up to 1 µF load
Measure accuracy50 V±(3% + 5)
100 V±(3% + 5)
250 V±(1.5% + 5)
500 V±(1.5% + 5)
1000 V±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ
General Specifications
Maximum voltage applied to any terminal:600 V AC rms or DC
Storage temperature-40°C to 60°C (-40°F to 140°F)
Operating temperature-20°C to 55°C (-4°F to 131°F)
Temperature coefficient0.05 x (specified accuracy) per °C for temperatures < 18°C or > 28°C (< 64°F or > 82°F)
Relative humidity
0% to 95% @ 10°C to 30°C (50°F to 86°F)
0% to 75% @ 30°C to 40°C (86°F to 104°F)
0% to 40% @ 40°C to 55°C (104°F to 131°F)
VibrationRandom, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
Shock1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)
Electromagnetic compatibilityIn an RF field of 3 V/M, accuracy = specified accuracy (EN 61326-1:1997)
SafetyComplies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement category IV 600 V (CAT IV)
CertificationsCSA per standard CSA/CAN C22.2 No. 61010.1-04; TUV per standard IEC/EN 61010-1 2nd Edition
BatteriesFour AA batteries (NEDA 15A or IEC LR6)
Battery lifeInsulation test use:Tester can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off.
Resistance measurements:Tester can perform at least 2500 earth bond resistance measurements with fresh alkaline batteries at room temperature. These are standard tests of 1 Ω with a duty cycle of 5 seconds on and 25 seconds off.
Size (H x W x L)5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
Weight550 g (1.2 lb)
IP ratingIP40
AltitudeOperating2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage)12,000 m
Over-range capability110% of range
Included accessoriesTL224 Test Leads, TP74 Test Probes, clips PN 1958654 (red) and PN 1958646 (black), holster and remote probe

Models: Fluke 1507 Insulation Resistance Tester

Fluke 1507
Fluke 1507 Insulation Resistance Tester
Part#: 5066006
UPC#: 0 95969 28867 5

Includes:

  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation
Fluke 1507 CAL
Fluke 1507 Insulation Resistance Tester, with a traceable certificate of calibration with data from Fluke
Part#: 5160560
UPC#: 0 95969 94682 7

Includes:

  • Remote probe
  • Test leads
  • Test probes
  • Alligator clips
  • User documentation
  • A traceable certificate of calibration with data from Fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 22.66ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 5 out of 5 by from Great Insulation tester I use it 2 years already. accurate reasults. always find the problems easy.
Date published: 2021-11-02
Rated 5 out of 5 by from Excellent meter Very good meter. I bought this meter last month and is excellent meter but I don't know why the volt scale shows 0.2 VDC.It should show 0.0 VDC.
Date published: 2018-12-26
Rated 5 out of 5 by from Excellent tester! I have owned a 1507 for over 10 years. If I ever have to replace it I would get another 1507 in a heartbeat. It is better than a hand cranked merger.
Date published: 2018-12-06
Rated 3 out of 5 by from Explain How To USe Not like my T-1000 or V87, this is different to use. Manual really dont explain, ohms????
Date published: 2018-02-16
Rated 5 out of 5 by from 1507 Megger I have had this tester for a while now and it has performed great. Very pleased with it and the accessories it came with. Can't beat the performance for the price.
Date published: 2018-02-14
Rated 5 out of 5 by from Insulation resistance plus more This Insulation Tester can do the test at several test voltages. It can also measure volts and ohms for other tests. It can measure small resistance such as in a grounding continuity test or a ground bond test.There is no crank to turn like the one on my old tester. I'm very happy with this tester.
Date published: 2017-08-30
Rated 5 out of 5 by from Fluke as always! Sure glad I bought this product. Has been am invaluable tool once I got it!
Date published: 2016-12-13
Rated 5 out of 5 by from Great tool Great tester! We use it for testing wiring after flood or fire damage. Very useful tool. Easy to use and a larger display make this a great tester.
Date published: 2016-12-12
  • y_2024, m_3, d_7, h_10
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.38
  • cp_1, bvpage1
  • co_hasreviews, tv_5, tr_14
  • loc_en_US, sid_1642006216756, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.52ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us page.