Key features

  • Measure 4 to 20 mA signals without breaking the loop
  • Source/simulate 4 to 20 mA signals and provide loop power
  • Source/measure DC voltage to verify power supplies or I/O signals
  • Best in class accuracy of 0.2%
  • Delivers 0.01 mA resolution and sensitivity

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
$1830.99
FREE Shipping
30-day Returns

Product overview: Fluke 773 Milliamp Process Clamp Meter

Save time and money by measuring output signals without shutting down the system

The Fluke 773 milliamp clamp meter is accurate, versatile, and highly portable. It saves time and money by measuring 4–20 mA signals five times faster than with traditional multimeters, and without breaking the loop. That means you can troubleshoot a live device without having to power down and possibly miss something going on in the process.

The 773 is ideal for troubleshooting transmitters, valves, and programmable logic controllers (PLCs) found in process plants. The 773 allows you to connect to a mA loop in a traditional series workflow to measure, source, or simulate a control system. And it measures up to 99.0 mA non-contact, including 10 to 50 mA signals in older control systems.

The 773 also sources and measures DC voltage, so it can be used to troubleshoot voltage input and output devices that accept a 1-5 V or 0 to 10 V signal. You can detach the clamp section of the meter and use it as a remote jaw, connected to the main body by an extension cable to make it easier to take measurements in tight spaces.

Work smarter with the 778 mA Clamp Meter

An integrated measurement spotlight allows you to illuminate hard to see wires in dark enclosures while a dual backlit display can show mA measurement and percent of 4 to 20 mA span simultaneously. Use the Hold function to capture measurements on-screen for verification and recording purposes. Plus, automatic power-off features save battery life so you can work longer without changing the batteries.

Advanced loop troubleshooting

With the unique mA scale feature users can measure a mA signal without breaking the loop and output that signal to another device to record the measurements. The 773 also includes simultaneous mA in-circuit measurement with 24 V loop power for powering and testing transmitter. You can also apply a mA input signal to a device and measure its 4-20 mA output on devices such as valves or mA isolators. Offers mA or voltage output linear ramp or 25% step output.

What's in the box:

  • Fluke 773 Milliamp Process Clamp Meter
  • (1 pair) TL75 test leads
  • AC72 detachable clip
  • (1 pair) TL 940 mini hook test leads 
  • (4) AA alkaline batteries (installed)
  • Magnetic Hanging strap
  • Soft carrying case
  • Quick Reference Guide
  • 3-year warranty

Specifications: Fluke 773 Milliamp Process Clamp Meter

Specifications
Diameter of measurable conductor0.177" or 4.5 mm max
Operating temperature-10 to 50ºC
Storage temperature-25 to 60ºC
Operating humidity< 90% @ <30ºC, < 75% @ 30 to 55ºC
Operating altitude0 to 2000 m
IP ratingIP 40
Size44 x 70 x 246 mm (2 7/8 x 5 ¾ x 11 5/8 in)
Weight410 g, (14.4 oz)
VibrationRandom 2 g, 5 to 500 Hz
Shock1 meter drop test (except the jaw)
EMI/RFIMeets EN61326-1
For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
Temperature coefficient0.01% ºC
(< 18ºC or > 28ºC)
Power, battery life(4) AA 1.5 V Alkaline, IEC LR6, 12 hours in mA source into 500 ohms
WarrantyThree years for electronics
One year for cable and clamp assembly
Functional Specifications
mA measurement
(measured by clamp)
Resolution / range0 to 20.99 mA
Accuracy0.2% + 5 counts
Resolution / range21.0mA to 100.0 mA
Accuracy1% + 5 counts
mA measurement (measured in series with test jacks)Resolution / range0 to 24.00 mA
Accuracy0.2% + 2 counts
mA source (maximum mA drive: 24 mA into 1,000 ohms)Resolution / range0 to 24.00 mA
Accuracy0.2% + 2 counts
mA simulate (maximum voltage 50 V dc)Resolution / range0 to 24.00 mA
Accuracy0.2% + 2 counts
Voltage source (2 mA maximum drive current)Resolution / range0 to 10.00 V DC
Accuracy0.2% + 2 counts
Voltage measureResolution / range0 to 30.00 V DC
Accuracy0.2% + 2 counts

Models: Fluke 773 Milliamp Process Clamp Meter

Fluke 773
Fluke 773 Milliamp Process Clamp Meter
Part#: 3362365
UPC#: 0 95969 47582 2

Includes:

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap
  • Fluke 773 Milliamp Process Clamp Meter
Fluke 773 CAL
Fluke 773 Milliamp Process Clamp Meter, with a traceable certificate of calibration with data from Fluke
Part#: 5160682
UPC#: 0 95969 94694 0

Includes:

  • Four AA alkaline batteries (installed)
  • Soft carrying case
  • TL75 test leads
  • AC 72 detachable clip
  • TL 940 mini hook test leads
  • Instruction sheet
  • Hanging tool with hook and loop strap
  • Fluke 773 Milliamp Process Clamp Meter
  • A traceable certificate of calibration with data from Fluke

what is the clamps size? what guage wire max?

Asked by: bbalkuv
The Fluke 773 Milliamp Process Clamp Meter's diameter of measurable conductor is .177&quot; or 4.5 mm max. The gauge for the wire size is approximately 6 gauge.
Answered by: FlukeCorporation
Date published: 2024-08-21

How is an ripple current measured at the DC-clamp. For example an DC current 10 mA with an 100 Hz ripple

Asked by: Andre
There is no spec for ripple current. However, the magnetic pickup on the clamp is highly susceptible to noise (i.e. being on or near an elevator). If you are looking for more specific information we suggest the data sheet, or instruction sheet found under the &quot;Manuals + resources&quot; tab.
Answered by: FlukeCorp
Date published: 2024-08-14
  • y_2024, m_12, d_5, h_7CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_1627893071924, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 45.04ms
  • QUESTIONS, PRODUCT
Rated 5 out of 5 by from Just what I needed. I ran into a situation where I needed to source power on my loop and this is the tool to do the job.
Date published: 2023-08-28
Rated 5 out of 5 by from Value for money I bought this meter thinking I mite get some use out of it, never really expecting it to be such a valuable asset to my daily fault finding role. The loop power and mA in out functions are brilliant. This meter is worth the high price paid for it. It is so easy to verify PLC analog inputs vs instrument issues, set up loop powered valves with feedback, etc without having to run in and out checking a HMI. Battery life is way better than expected Fluke connect & 24V source would be valuable upgrades
Date published: 2023-06-05
Rated 5 out of 5 by from Major Time Saver I have been using this meter for quite a while around water treatment plants and found it to be very useful at troubleshooting current loops. Clamp on meters for DC are relatively new but this works without bugs. We have both a 772 and a 773 meter. The 773 allows sourcing of a signal providing fast verification of new wiring. It is also quick to determine if an instrument has a faulty output or the display/PLC module is bad. There is no need to break a circuit to see why there is no voltage. It is almost a must-have for commisioning new IO.
Date published: 2016-12-15
Rated 5 out of 5 by from A Time Saver The Fluke 773 Meter has made my work with process instrumentation far more enjoyable. Having to not break the loop to check the current is invaluable, and having voltmeter functionality available in the same meter saves even more time. Only one minor complaint -- the supplied leadset isn't up to the usual Fluke standard -- the wires are small and flimsy, rather than the nearly-indestructible test leads normally supplied with all other fluke meters that I've purchased.
Date published: 2016-12-10
Rated 5 out of 5 by from Very satisfied This tool has been very useful for working with building controls and calibrating energy meters.
Date published: 2016-12-08
Rated 5 out of 5 by from Very Handy Tool The Fluke 773 is a great help when troubleshooting control loops. The ability to measure a 4-20ma signal without breaking the circuit is awesome!
Date published: 2016-12-08
Rated 5 out of 5 by from No Breaking the Loop This is an incredible troubleshooting tool. Quick check for mA with a error of only .06 mA in most cases. The VDC measurement, source, and simulate functions just add to the usefulness. I am very pleased with my purchase
Date published: 2016-12-08
Rated 5 out of 5 by from Awesome All in One!, Process Meter Couldn't be any better don't have to switch meters for measuring, simulating, or source a current loop. Fantastic!
Date published: 2016-12-07
  • y_2024, m_12, d_6, h_7
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_3, tr_14
  • loc_en_US, sid_1627893071924, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.6ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat