Clamp meter resources and solutions

Learn how to use clamp meters to quickly troubleshoot some of the most common problems in HVAC and electrical installations, and how to stay out of the blast zone when reading measurements. Get the most out of your clamp meter and know when it’s best to use a clamp meter vs. a digital multimeter.

Helpful resources

Find the right clamp meter

Speak to a Fluke specialist

Clamp Blog TOC image

On-demand webinars

Clamp meters

  • Watch now

All clamps articles

Article

Leading facility solutions firm upgrades popular instrument with Fluke Connect model

MacDonald-Miller standardized on the Fluke 902 Clamp Meter when it came out several years ago.

Article

How to Measure Current with a Clamp Accessory

How to measure current with a digital multimeter plus clamp accessory.

Article

How to Use Fluke Connect™ software with the Fluke 377 FC and Fluke 378 FC FieldSense™ clamp meters

Fluke Connect software on the 377 FC and 378 FC clamp meters allows you to record, analyze, and share results with others. Trend data for preventive maintenance.

Article

What is a clamp meter?

Clamps measure current. Probes measure voltage. Having a hinged jaw integrated into an electrical meter allows technicians to clamp the jaws around a wire, cable and other conductor at any point in an electrical system, then measure current in that circuit without disconnecting/deenergizing it.

Article

How to measure current with a clamp meter

Measuring ac current with a clamp meter’s jaws. Note: Current flowing in opposite directions cancels each other. If current is moving in opposite directions, place just one conductor within the clamp during measurement.

Article

Case study: Electric utility plays it safe...

The safety rated Fluke T+Pro gets field-tested by non-electricians. Larger buttons for gloved hands and a battery life indicator helped to make the transition from the old solenoid-based testers to the T+Pro much easier.

Article

Why use a CAT III rated meter in solar PV installations?

One essential tool for installing, monitoring, and testing photovoltaic systems is the Fluke 393 FC solar clamp meter – rated CAT III 1500 V/CAT IV 600 V for CAT III environments including solar installations.

Article

How to Get Faster 3 Phase Power Measurements with Clamp Meters

Get 3 phase power measurements 50% faster with Fieldsense clamp meters. How to measure 3 phase voltage and current simultaneously.

Article

Guide to Clamp Meter Symbols: Diagram, Buttons, Dial, Display

Guide to clamp meter symbols, buttons, display and dial functions.

Article

Top 10 solar installation and maintenance tools

Solar power is one of the world’s fastest growing sources of energy. The industry and those who support it through services and related hardware and software are improving and innovating at a rapid pace.

Article

How a solar rooftop contractor ensures quality panel installations every time

Using Fluke’s 376 True RMS Clamp Meter, a rooftop solar contractor saves time and ensures quality panel installation by testing throughout the installation process.

Article

How to choose the right clamp meter for your job

Fluke’s assortment of clamp meters has been engineered to address a wide variety of needs, from routine tasks to specialty projects.

Article

Clamp Meters vs Multimeters

A digital multimeter is essentially a voltage-measuring tool with some current abilities. A clamp meter is basically a current-measuring tool with some voltage abilities. They are distinctly different instruments, each with its own advantages.

Article

Leakage current measurement basics

On circuits protected by GFCIs (Ground Fault Current Interrupters), leakage current can cause unnecessary and intermittent tripping. In extreme cases, it can cause a rise in voltage on accessible conductive parts.

Article

Clamp meter readings: problems and solutions

Since a small increase in current flow to a motor produces a proportionately larger amount of heat, motor amperage exceeding nameplate values should be carefully investigated as a possible cause. These overload trips, though often caused by motor loading issues, can also indicate bearing failure, insulation breakdown or voltage unbalance.

Article

Why is there an arrow on your current clamp?

Learn why on all current clamps and current clamp accessories, there is an arrow placed close to the beak or inside the beak opening.

Article

Breaking new ground without breaking the loop

Early reports from the field suggest that the new Fluke 772 and 773 Milliamp Process Clamp Meters may be game changers, breaking new ground for technicians in the HVAC controls industry. With the feature sets these meters offer, troubleshooting of the most common problems in modern control systems becomes a snap.

Article

What are Hall Effect (ac, dc) clamp meters?

Hall Effect clamp meters can measure both ac and dc current up to the kilohertz (1000 Hz) range

Article

Troubleshooting 4 to 20 mA Process Control Systems without Breaking the Loop

Troubleshooting 4 to 20 mA (milliamp) process control systems without breaking the loop using Fluke 773 Milliamp Process Clamp Meter

Article

How to measure signals using test probes

Fluke’s assortment of clamp meters has been engineered to address a wide variety of needs, from routine tasks to specialty projects.

Article

Inside flexible coil clamp meters

Clamp meters with flexible coil probes can fit into tight spaces

Article

Why ruggedness matters in a clamp meter

Fluke engineers its clamp meters to withstand a high degree of unconventional use—as a wedge, makeshift pliers, nutcracker, whatever a tech might dream up in a moment of need.

Article

How and why to measure inrush current

Knowing the value of inrush current helps technicians locate startup problems

Article

Using accessory current clamps with Fluke Digital Multimeters

Accessory current clamps expand a multimeter's flexibility and measurement capabilities by allowing it to measure up to thousands of amps.

Article

Inside current transformer (ac) clamp meters

An interior view of a Fluke 325 clamp meter

Article

Types of clamp meters

Types of clamp meters

Article

Guide to Using FieldSense in the 377 FC and 378 FC Clamp Meter

Best ways to use the 377 FC and 378 FC clamp meter, how FieldSense technology works and ideal applications for front-line technicians and electricians.

Article

How to use the power quality indicator on the 378 FC clamp meter

Detect basic 3 phase power quality issues with the versatile Fluke 378 FC clamp meter for industrial electricians. Increase productivity and safety without test leads.

Article

Clamp meter safety tips

Safety is always a priority when working with electricity in industrial sites.

Chat with ourFluke assistant
Clear Chat