English

67 MAX Clinical Infrared Thermometer

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 26.51ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke 67 MAX High Accuracy Infrared Thermometer
  • Precision infrared thermometer: ± 0.5 °F from 71.6 °F to 109 °F (± 0.3 °C from 22 °C to 43 °C)
  • Thermal scanning of human skin temperature
  • Body mode compensates for the difference between forehead surface temperature and core body temperature

Key features

  • Ships late October 2020
  • Clinical infrared thermometer: ± 0.5 °F from 71.6 °F to 109 °F (± 0.3 °C from 22 °C to 43 °C)
  • Non-contact thermal scanner device for measurement of human body temperature
  • Adjustable alarm visually alerts the user when the temperature exceeds a programmed limit.
  • Offers small, lightweight form factor to slip in a coat pocket

Product overview: 67 MAX Clinical Infrared Thermometer

Body temperature results in seconds.

The Fluke 67 MAX Clinical Infrared Thermometer* is a handheld non-contact thermometer optimized for measuring human temperature. The Fluke 67 MAX is accurate within +/- 0.5 °F over a measurement range of 71.6 °F to 109 °F (+/- 0.3 °C accuracy within range from 22 °C to 43 °C).

The Fluke 67 MAX has a built-in Body Mode, which adds an offset to account for the difference between surface skin temperature and core body temperature. The SCAN functionality allows the user to scan the forehead for the highest temperature to improve measurement repeatability, when compared to a single spot temperature measurement. This permits convenient forehead scans within seconds. The Fluke 67 MAX also has a fixed emissivity setting of 0.98, which is widely accepted as the most accurate setting for measuring human skin temperature.

The Fluke 67 MAX has been tested to IEC standard 60601-1-2 for electromagnetic compatibility. This tool has been tested to remain accurate when near other electronic devices such as portable RF communication equipment (two-way radios).

The Fluke 67 MAX, with its small size and versatile features, is extremely easy to use. Plus, it’s rugged enough to take a 2-meter drop, helpful if you work in busy, crowded work areas. You can also easily clean the surface of the Fluke 67 MAX with disinfecting wipes.

*The Fluke 67 MAX accuracy complies with and accuracy tested in accordance with ASTM E1965-98 and ISO 80601-2-56 standard but is not FDA 510(k) cleared or approved

Specifications: 67 MAX Clinical Infrared Thermometer

Specifications
Temperature measurement range71.6 °F to 109.4 °F (22 °C to 43 °C)
Accuracy± 0.5 °F from 71.6 °F to 109.4 °F (± 0.3 °C from 22 °C to 43 °C)
Spectral response8 to 14 microns
Emissivity0.98 (fixed)
Measurement distance range2 to 6 inches (50 to 150 mm)
Display resolution0.1°F (0.1°C)
PowerAA battery
Battery life100 hours
Physical Specifications
Weight8.8 oz (250 g)
Size6.88 x 3.34 x 2.95 in (175 x 85 x 75 mm)
Operating temperature59 °F to 104 °F (15 °C to 40 °C)
Storage temperature-4 °F to 122 °F (-20 °C to 50 °C), without battery
Operating humidity10% to 95% RH non-condensing
Operating altitude2000 meters above mean sea level
Storage altitude12,000 meters above mean sea level
Drop test6.5 feet (2 meters)
Vibration and shockIEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
Electromagnetic complianceIEC 60601-1-2: Portable electromagnetic equipment
Standard complianceIEC 60601-1: Pollution degree 2
ASTM E1965: 22 to 40.0 °C
IEC 80601-2-56: 34.0 °C to 43.0 °C

Models: 67 MAX Clinical Infrared Thermometer

Fluke 67 MAX

Fluke 67 MAX High-Accuracy Infrared Thermometer

Includes:

  • Non-contact clinical infrared thermometer
  • Manual
  • (1) AA battery
  • Registration card
  • Statement of calibration

Reviews: 67 MAX Clinical Infrared Thermometer

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 41.32ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;