Fluke Set of 3 5A/50A Current Clamps

Model#: Fluke MBX Clamp 5A/50A Part#: 2539468 UPC#: 0 95969 32471 7
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 22.49ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Fluke Set of 3 5A/50A Current Clamps

Product overview: Fluke Set of 3 5A/50A Current Clamps

Expand the capabilities of the Fluke 1735 and Fluke 1740 Series Loggers with the dual-range 5 A/50 A current clamps. The accessory includes three precision clamps that are automatically detected and scaled by the instrument when attached.

Specifications: Fluke Set of 3 5A/50A Current Clamps

Specifications
Electrical characteristicsNominal current in50 A AC rms
Overloadup to 100 A rms
Conductor position influence< 0.5% of range at 50/60 Hz
Error due to adjacent conductor≤ 15 mA/A at 50 Hz
Phase shift at 2 kHz at 200 A< ±1°
Frequency range40 Hz to 10 kHz (-3 dB)
Temperature coefficient0.015% of range / °C
Working voltage (see section safety)600 V AC rms or DC
Order reference1-phase: EP0442A
3-phase: EP0452A
3-phase+N: EP0453A
AccuracyPrimary current 0.125 A to 2.5 AOperating error in % of reading: ±2.5%
Phase shift: not specified
Primary current 2.5 A to 12.5 AOperating error in % of reading: ±1.5%
Phase shift: < 2°
Primary current 12.5 A to 25 AOperating error in % of reading: ±0.5%
Phase shift: < 0.5°
Primary current 25 A to 50 AOperating error in % of reading: ±0.5%
Phase shift: < 1°
General characteristicsMaximum conductor size15 mm diameter, bus bar 15 x 17 mm
Cable length2 m
Operating temperature range-10°C to +55°C
Storage temperature range-20°C to +70°C
Operating humidity15% to 85% rh (non condensing)
Weight (per clamp)175 g
Reference conditionsEnvironment temperature range+18°C to +26°C
Humidity20% to 75% r.h.
Currentsinusoidal waveform, 48 to 65 Hz, distortion factor: < 1%, no DC component
Load impedance for voltage output≥ 1 MΩ, <100 pF
Safety standardsIEC/EN61010-1: 2001
IEC/EN61010-2-032
IEC/EN61010-2-031
Safety600 V CAT III, pollution degree 2
The application of the clamps on uninsulated conductors is limited to 600 V rms or DC to ground and frequencies below 1 kHz.
EMC standardsEN61326-1: 1997/A1: 1998
Dimensions102 x 42.5 x 23.5 mm

Models: Fluke Set of 3 5A/50A Current Clamps

Fluke MBX Clamp 5A/50A

Set of 3 5A/50A Current Clamps

Part#: 2539468
UPC#: 0 95969 32471 7
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 71.43ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.42ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us page.
How can I help you today?