Temperature calibration

Temperature affects nearly every industrial process, making accurate calibration essential. This collection explores temperature calibration methods, reference standards, and best practices for laboratory and field applications. Learn how to improve stability, reduce drift, and maintain traceable temperature measurements.

From thermocouples to fixed-point cells, these resources help you solve real-world temperature measurement challenges.

Fluke Temperature Calibration

All temperature calibration articles

Article

Industrial Temperature Calibrator Selection Guide

A temperature calibrator, often called a thermometer calibrator, is used to remove inaccuracies in installed thermometers and temperature sensors, because temperature measurement is a critical parameter in many industrial processes.

Article

Common problems in achieving maximum performance from dry-well thermometer calibrators

Article

How to complete the top 5 calibrations with the 55X0A Multi-Product Calibrator: Video quick start guide

Watch how to run the 5 most common calibration tests using the 5560A, 5550A and 5540A Multi-Product Calibrators on your clamp meters and multimeters.

Article

Why did my temperature sensor fail calibration?

Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

Article

Calculating Uncertainties in a Thermocouple Calibration System: App Notes Series, 3 of 4

There are several calibration uncertainties to be evaluated in determining the accuracy of a thermocouple calibration system.

Article

Selecting the right temperature probe-to-readout adapter

A temperature probe is typically ordered with a termination that matches the calibration equipment it will be used with

Article

Accurate Fever Scanning with Infrared Forehead Thermometers: Issues, Solutions and How to Calibrate

See 10 steps of how to check the accuracy of an infrared thermometer designed for measuring human body temperature. Learn best practices & how things work.

Article

Inside Fluke’s most accurate multimeters: the 8588A and 8558A 8.5-digit digital multimeters

Fluke's latest 8588A and 8558A high performance DMMs include several new and innovative improvements to help you do your job right. See for yourself here.

Article

How to Calibrate a 67 MAX Infrared Thermometer

This article summarizes what you need to verify that your Fluke 67 MAX Infrared Thermometer is performing within its published specifications. Note that we are only talking about verifying the thermometer, not adjusting it. If your 67 MAX requires adjustment please contact your local Fluke service provider.

Article

How to Select an Electrical Calibrator

Successful selection of a calibrator involves a thorough analysis of the specifications of both the equipment to be tested and the calibrating standards.

Article

How to Calibrate a Thermocouple: App Notes Series, 4 of 4

Thermocouple connection to the readout depends whether an internal or external reference junction is used. Internal reference junctions are generally used for high throughput, low-to-medium accuracy applications. There is less opportunity for error and the process is simpler

Article

How traceability is restored to infrared calibration

Find out how traceability of infrared thermometers is impacted by the traditional approach to servicing IR calibrators.

Article

Getting to “Yes”: How to justify the purchase of new calibration equipment

Worried your boss won't approve a needed calibrator purchase? Learn and get the resources here to show why the purchase can be a smart business decision.

Article

A calibration bath review

Choosing a bath should not be that difficult but there are a lot of choices. For some, it’s unfamiliar territory and in that case, I thought you might like to have a map.

Article

1594A/1595A Super-Thermometer Resource Center

Temperature fixed point cells are ITS-90 primary standards that demand low uncertainty measurements for calibration purposes. Traditionally, fixed-point cell measurements have been handled by resistance ratio bridges

Article

How to configure your piston gauge

Learn how to configure your piston gauge for precise and reliable pressure measurement. Discover the benefits of different types of piston gauge configurations, how to select the right piston cylinder, and related resources to help you choose the best option for your application.

Article

ISO/IEC 17025:2017 Training Online

Fluke Calibration offers free, online ISO 17025 training to address the 2017 changes in the form of this article and training webinars. Get the info here.

Article

Establishing Correct Calibration Intervals

Learn what a calibration interval is, variables that affect it, who is responsible for setting it & how to establish one for your measurement equipment.

Article

Electrical Load Limitations of Transconductance Amplifiers

The transconductance amplifier (TA) is a widely used, stable, and accurate source of electrical current. TA’s are commonly used for testing and calibration of current sensors such as shunts, current transformers (CT’s), and Rogowski coils. The TA is also used in basic research applications requiring accurate and stable source of current.

Article

Tempmeko 2019 Temperature Metrology Conference – Fluke Calibration’s Overview of the Conference

Temperature metrology experts from Fluke Calibration attended Tempmeko 2019 and provide an overview of the top 5 topics covered there, including some photos.

Article

Jeff Gust Reflects on the Importance of Trust in Calibration

Article

Temperature baths increase stability in medical device manufacturing and tempering process

For medical device manufacturing, especially with nitinol, learn how to improve stability and uniformity by using a high-temperature salt calibration bath.

Article

How to do a temperature sensor comparison calibration

See this illustrated blog post to learn how to do a comparison calibration of a probe-style RTD at one temperature point using a dry-block calibrator.

Article

Electronic vs. Traditional Deadweight Testers

Learn how a deadweight tester calibrates an analog pressure gauge and see the pros and cons of traditional vs electronic deadweight testers (E-DWT).

Article

Buying the right temperature calibration bath for your laboratory

Learn the questions you should ask before you buy a temperature calibration bath. Learn the 4 key specifications that should be customized for your application.

Article

Infrared Temperature Calibration 101

Learn the basics of infrared temperature calibration including how infrared thermometers work, emissivity, blackbodies, detecting radiance & more.

Article

How to calibrate a thermocouple

You’ll want to test thermocouples at regular calibration intervals & if you suspect them of failing to meet performance specifications. Learn how here.

Article

Why a Fluke calibration bath?

See why Fluke makes the best liquid bath calibrators & sells the most. Excelling in range of baths, controllers, automation, technology, mixing, & maintenance.

Article

How to choose a blackbody or Infrared temperature calibrator

Though the principle of radiation thermometry has been used in industry for decades, its recent growth in the HVAC, factory maintenance, aerospace, and energy industries is causing many people to inquire about infrared (IR) thermometers and the calibration equipment needed to support them

Article

How to calibrate an oscilloscope for phasing

Understand how to calibrate an oscilloscope for phasing with our step-by-step guide.

Article

Temperature Measurement and Calibration Resource Center

Article

How to clean an infrared calibrator target

The black body paint is very delicate. To remove dust or debris from the paint, the only thing you can do is use compressed dry air. See the dos & don’ts.

Article

Five easy steps for choosing an industrial temperature readout and probe

Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

Article

Temperature Simulation in Temperature Calibration

Temperature simulation is often usen in you calibrating thermometers for process measurement and control. Unfortunately many technicians are often only doing half the job.

Article

Selecting a Dry-Well (Dry-Block) Temperature Calibrator

Learn how to select a dry well (dry block) temperature calibrator in this application note from Fluke Calibration. Choose the right calibrator for your specific workload. All Fluke options are accurate, stable, flexible, and portable. Request product pricing today.

Article

Temperature and pressure, nuclear fusion calibration at the National Ignition Facility

Article

Automating temperature sensor calibration with the Fluke Calibration 1586A Super-DAQ

Article

Best practices for process temperature calibration

Article

10 reasons you need a 1594A or 1595Aa Super-Thermometer

Article

Improving triple point of water cell accuracy

Article

Testing temperature uniformity on a flat-plate infrared calibrator

Article

Proper calibration of industrial temperature process systems

Article

Producing the highest accuracy from SPRTS

Article

Metrology 101: IR thermometer calibration

Article

Improving dry-well calibrations

Article

Temperature probe calibration and recalibration

Article

How to choose a calibration bath

Choose the perfect calibration bath to suit your needs. Discover the importance of controllers, automation, heating technology, fluid mixing, and maintenance.

Article

Calibrating industrial temperature sensors

Article

Calibrating a Heat Source using MET/TEMP II

Fluke Calibration provides solutions to all FAQs related to calibrating a heat source using MET/TEMP II.

Article

1586A Super-DAQ Precision Temperature Scanner Resource Center

Save time and money by using a 1586A Super-DAQ and a Fluke Calibration dry-well, fluid bath, or furnace to automate the calibration of up to 40 temperature sensors—simultaneously, without requiring a PC or software.

Article

Industrial temperature readout and probe selection guide

Guide for selecting a thermometer readout and companion reference standard probe

Article

Automate temperature sensor calibration with a 1586A Super-DAQ Precision Temperature Scanner

Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

Article

Establishing calibration intervals for Fluke products

Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

Article

Calibration Bath Selection Guide

Calibration baths from Hart Scientific offer high stability, flexibility , and are a preferred choice of National Metrology Institutes. Contact us today for more information.

Article

IO Toolkit

The IO Toolkit was designed to connect to only one instrument at a time. Running more than one instance of the software simultaneously on a computer has not been tested.

Article

Making the Right Choice for Your Temperature Readout

Fluke Calibration produces the broadest range of electrical, RF, temperature, pressure & flow calibration instruments & software that help measurement professionals around the globe.

Article

Fluke Calibration Bath Safety Features

The Fluke Calibration metrology baths use the 2100 temperature controller which has the following built-in safety devices.

Article

Installing MET/TEMP II FAQs

MET/TEMP II is intended to replace Fluke's MET/TEMP software. MET/TEMP II is a completely different software package than MET/TEMP

Article

Interface-it

Article

Frequently Asked Questions for Temperature Calibration Software

Article

How to go From Paper Charts to State of the Art

Article

How to Select a Calibration Bath Fluid

Article

Calibration baths, physics, and the black arts

How can a bath that is working perfectly not be capable of reaching a temperature inside its own operating range? The answer lies in the properties of the fluid media chosen for the calibration bath. As usual, these properties depend on temperature.

Chat with ourFluke assistant
Clear Chat