As a homeowner, knowing how to tackle basic electrical tasks saves you time and money while ensuring your home stays safe and functional. Whether you're installing a new light fixture or troubleshooting a faulty outlet, having the right tools on hand enables you to get the job done without calling a professional.
Here are the six must-have electrical tools from Fluke that every homeowner should add to their toolbox.

1. Fluke 1AC II Non-Contact Voltage Tester
A non-contact voltage tester, or volt pen, is a simple yet essential tool for quickly determining if an electrical circuit is live. It helps you avoid the risk of accidental shock before working on outlets, switches, or wiring. The Fluke 1AC II Non-Contact Voltage Tester is a highly reliable volt pen with a bright indicator light that also produces audible alerts when it detects voltage. It’s an indispensable safety tool for any homeowner performing electrical work.
Ready to grab your Fluke 1AC II Non-Contact Voltage Tester? Check out your options now.
Where it’s useful:
- Checking if an outlet is powered before replacing a fixture.
- Testing wires in an electrical box before handling them.
2. Fluke IKSC7 Insulated Screwdriver Set
Electrical work often involves tightening or loosening screws on outlets, breaker panels, and fixtures. An insulated screwdriver set protects you from accidental contact with live electricity, reducing the risk of electric shock. The Fluke IKSC7 Insulated Screwdriver Set provides durable, insulated screwdrivers designed for safety. Work on electrical systems with confidence and protect yourself from shocks with this versatile toolkit.
Need a single Phillips head screwdriver? Or do you need a full set? Check out your options now.
Where it’s useful:
- Installing light switches and outlets.
- Tightening connections in an electrical panel.
- Assembling and disassembling household appliances.
3. Fluke ST120 GFCI Socket Tester
Socket testers check whether outlets are correctly wired. They also confirm if ground-fault circuit interrupters (GFCIs) are working properly. GFCIs are required in kitchen, bathroom, and outdoor outlets to prevent electrical shock. The Fluke ST120 GFCI Socket Tester makes it easy to confirm your home’s outlets are safe and up to code, helping you troubleshoot common electrical problems effortlessly.
This is one tester you will not regret having handy. Go get it. Stay safe.
Where it’s useful:
- Testing newly installed outlets for correct wiring.
- Checking GFCI outlets to ensure they trip correctly.
- Diagnosing open grounds, reversed polarity, or other wiring issues.
4. Fluke BK120 Electrical Test Kit
The Fluke BK120 Electrical Test Kit equips homeowners with two handy measurement tools: the Fluke BK120 SmartTrace Breaker Finder™ and Fluke T5-600 Electrical Tester. Together, this duo equips you with everything you need for basic electrical troubleshooting.
Where it’s useful:
- Testing circuits and identifying faulty wiring.
- Measuring voltage and continuity in household electrical systems.
- Checking fuses and circuit breakers.
5. Fluke 107 Pocket Digital Multimeter
Every homeowner doing their own electrical work needs a digital multimeter (DMM). These versatile tools measure voltage, current, and resistance in household circuits. Whether you're checking battery power, troubleshooting an appliance, or verifying an outlet’s voltage, a multimeter can help you get the job done.
The Fluke 107 Pocket Digital Multimeter is compact, easy to use, and provides accurate readings, making it a must-have for homeowners handling electrical tasks.
Where it’s useful:
- Diagnosing faulty electrical connections.
- Checking the voltage of household outlets.
- Testing batteries and small electronics.
6. Fluke TC01A/TC01B iSee™ Mobile Thermal Camera
Thermal imaging allows you to identify problems that aren't visible to the naked eye, such as insulation gaps or overheating electrical components. By detecting these issues early, you can address them before they escalate into costly repairs.
The Fluke iSee™ Mobile Thermal Camera - TC01A/TC01B offers precise temperature readings and can help homeowners detect potential problems before they become major catastrophes.
You want this. We all do. Go SEE for yourself what all the fuss is about.
Where it’s useful:
- Checking if a breaker is running hot.
- Diagnosing temperature fluctuations in HVAC systems.
- Testing home appliances for overheating issues.
Conclusion
Investing in high-quality, reliable electrical tools enhances household safety and empowers you to tackle DIY projects with confidence.
Having the right electrical tools at home equips you to handle minor electrical tasks safely and efficiently. Whether you’re troubleshooting an outlet, installing a light fixture, or checking your home’s wiring, these Fluke tools are useful additions to your toolkit.