How to Perform Automotive Continuity Checks with a Multimeter
Continuity testing helps you quickly verify whether a wire, fuse, switch, or relay is conducting electricity without breaks. In automotive diagnostics, it's essential for locating open circuits, faulty grounds, or failed components. The Fluke 88V multimeter simplifies this process with an audible tone and a fast-reacting continuity mode.
Introduction to the Fluke 88V for Automotive Use
The Fluke 88V is designed for technicians working in complex automotive electrical environments. Its continuity mode provides both a digital resistance reading and
a beep tone when it detects a good connection, speeding up the diagnosis of wiring faults and component failures.
Safety First When Checking Automotive Circuits
- Disconnect battery power or isolate the circuit before testing for continuity.
- Avoid testing powered circuits in continuity or resistance mode — this can damage the meter.
- Use caution around sensitive electronic modules. Static discharge or improper probing can also cause damage.
- Always verify that capacitors are fully discharged before testing continuity.
Basic Multimeter Setup Recap
- Function Selection: Set the dial to Ω (resistance), then press the
continuity button. - Correct Jacks: Red lead in V/Ω, black lead in COM.
- A beep indicates continuity (typically, resistance below ~25–50 ohms).
Step-by-Step Guide to Performing Automotive Continuity Checks with a Multimeter

Step 1. Ensure Power Is Off
- Disconnect the battery negative terminal or ensure the circuit is not live.
- If testing a removed component (like a fuse), power disconnection is not required.
Step 2. Set the Meter to Continuity Mode
- Insert the black lead into the COM jack.
- Insert the red lead into the V/Ω jack.
- Turn the dial to Ω, then press the continuity button (look for sound
symbol on screen).
Step 3. Touch Probes to Each Side of the Circuit Path
- Example uses:
- Across a fuse
- Across switch terminals
- End-to-end on a wire harness
- A steady beep with a near-zero reading (~0.0–0.2 Ω) indicates good continuity.
Step 4. Interpret the Reading
- Beep + Low Reading: Good continuity (closed circuit).
- No Beep + OL or High Reading: Open circuit or very high resistance — indicates break, corrosion, or bad connection.
Step 5. Confirm Ground Continuity (Optional)
- Place one lead on bare engine block or chassis ground.
- Place the other lead on a component ground terminal or wire.
- If no continuity, suspect a broken ground strap or a corroded terminal.
Tips and Best Practices
- Test known-good components first to verify the meter is working properly.
- For intermittent issues, wiggle wires during testing to simulate vibration
or movement. - Label your test results when checking multiple circuits in a harness or relay box.
- Don’t confuse continuity with voltage — continuity means low resistance, not necessarily that voltage is present.
Conclusion
Performing automotive continuity checks with the Fluke 88V is one of the quickest ways to verify electrical integrity across wires, switches, and connectors. It’s an essential diagnostic step for solving no-start conditions, dead accessories, or inconsistent sensor readings, making it a fundamental tool in every technician’s workflow.