Russian

Fluke Solar Site Survey Irradiance Meter with Mounting Bracket

  • Fluke Solar Site Survey Irradiance Meter with Mounting Bracket
  • Fluke Solar Site Survey Irradiance Meter with Mounting Bracket
  • Fluke Solar Site Survey Irradiance Meter with Mounting Bracket
  • Fluke Solar Site Survey Irradiance Meter with Mounting Bracket
  • Fluke Solar Site Survey Irradiance Meter with Mounting Bracket

Ключевые особенности

  • Measure solar irradiance, ambient and PV module temperature, array orientation and tilt angles
  • Make instantaneous measurements to determine the watts per square meter solar irradiation, required by IEC 62446-1 standard
  • High contrast LCD with large numbers for easy readability in direct sunlight
  • Part of the Fluke solution for I-V curve measurements, the IRR2-BT wirelessly communicates with the SMFT-1000 for instant and accurate readings

Обзор прибора: Fluke Solar Site Survey Irradiance Meter with Mounting Bracket

Solar site survey all-in-one tool 

From performing surveys and solar panel installation to executing the maintenance and performance of photovoltaic systems, the Fluke IRR2-BT Solar Irradiance Meter gives you the four critical measurements needed in one easy-to-use tool. 
  • Make instant measurements to determine the watt per square meter solar irradiation, required by IEC 62446-1 standard. 
  • Measure temperature by placing the meter directly on the panel or by connecting the external probe. 
  • Find cardinal direction with the compass.
  • Verify inclination of a roof or panel with the tilt function. 

Convenient mounting bracket 

The Fluke Solar Site Survey Irradiance Meter comes with a convenient mounting bracket, so that accurate solar irradiance and temperature measurements can be taken at the panel. Simply connect to bracket to the edge of a panel and secure the external probe to the back of the panel for accurate readings.

Wireless connection with the SMFT-1000 Multifunction PV Analyzer

The Fluke Solar Site Survey Irradiance Meter communicates wirelessly with the SMFT-1000 Multifunction PV Tester and Performance Analyzer to produce a highly accurate I-V curve instantly, making it easy to determine if a PV system is operating as designed.  When the units are synced, irradiance and temperature measurements are instantaneously sent to the analyzer for easy recording while working in the field. 

 

Характеристики: Fluke Solar Site Survey Irradiance Meter with Mounting Bracket

Irradiance
Measuring range50 to 1400 W/m²
Resolution1 W/m²
Measuring accuracy±(5 % + 5 Digit)
Temperature Measurement
Measuring range-30 °C to 100 °C (-22 °F to 212 °F)
Resolution0.1 °C (0.2 °F / 1 °F @ > 100 °F)
Measuring accuracy±1 °C (±2 °F) @ -10 °C to 75 °C (14 °F to 167 °F)
±2 °C (±4 °F) @ -30 °C to -10 °C (-22 °F to 14 °F)
75 °C to 100 °C (167 °F to 212 °F)
Note: Temperature measurement response time: ~30 sec.
Inclination Angle
Measuring range-90° to +90°
Resolution0.1°
Measuring accuracy±1.5° @ -50° to +50°
±2.5° @ -85° to -50° and +50° to +85°
±3.5° @ -90° to -85° and +85° to +90°
Note: Inclination accuracy is specified as the angle between a vertical and the absolute horizontal plane/true horizontal baseline. The Product is calibrated to true horizontal 0°.
Compass
Measuring range0° to 360°
Resolution
Measuring accuracy±7°
Note: Measurements valid for device inclination between -20° and +20° to horizontal. Outside that range, --- shows on the LCD. Result is in reference to magnetic north.
Memory
TypeEEprom
Size (kB/records)64 kB/6400
Recording time17 hours
RTCYes (super CAP supply)
CommunicationBT: BL653 module (only with SMFT)
Power Supply and Battery Life
Batteries4x AA IEC LR6
Battery life (typical)50 hours (>9000 readings)
Auto power off30 minutes
Temperature
Operating (IRR2-BT)-20 °C to 50 °C, humidity <80 %,
noncondensing
Operating (80PR-IRR)-30 °C to 100 °C
Storage-30 °C to 60 °C (humidity <80 %)
Altitude0 m to max. 2000 m
Wireless Radio Module
Frequency range2.402 GHz to 2.480 GHz
Output power8 dBm
Dimensions
Size150 mm x 80 mm x 35 mm (5.90 in x 3.14 in x 1.37 in)
Weight231g (0.5 lb)
Protection
Ingress ProtectionIEC 60529 IP40
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A Equipment (Industrial Broadcasting & Communication Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.