English

Fluke 287 and 289 Multimeter Firmware Update

Fluke 287 multimeters beginning with serial number 42700001 and Fluke 289 multimeters beginning with serial number 42830001 ship with firmware version 1.41. Older versions of the Fluke 287 or 289 with lower serial numbers cannot be upgraded to version 1.41

Fluke 287 Firmware update version 1.16

Owners of Fluke 287 multimeters with serial number 42700000 or LOWER can update to firmware version 1.16. These multimeters are NOT upgradable to any firmware higher than 1.16.

To upgrade your 287 to the latest firmware, follow these simple instructions:

  1. Click this link to download and save the firmware upgrade file.
  2. Ensure your Fluke 287 is connected to your computer using your Fluke USB-IR serial cable and run the file.

Version 1.16 corrects an issue where recording sessions could be interrupted or terminated when using the record function in combination with ambient conditions of bright sunlight or other sources of bright light, when used without the IR cable attached. Version 1.16 does not apply for units labeled 287/TPWS or 287/NUC.

Software licensing information that is required for the open-source software used is available here.


Fluke 289 Firmware update version 1.16

Owners of Fluke 289 multimeters with serial number 42830000 or LOWER can update to firmware version 1.16. These multimeters are NOT upgradable to any firmware higher than 1.16.

To upgrade your 289 to the latest firmware, follow these simple instructions:

  1. Click this link to download and save the firmware upgrade file.
  2. Ensure your Fluke 289 is connected to your computer using your Fluke USB-IR serial cable and run the file.

Version 1.16 corrects an issue where recording sessions could be interrupted or terminated when using the record function in combination with ambient conditions of bright sunlight or other sources of bright light, when used without the IR cable attached. Version 1.16 does not apply for units labeled 287/TPWS or 287/NUC.

Software licensing information that is required for the open-source software used is available here.


A Fluke USB-IR serial cable is required to upgrade your software. Don't have a cable? You can order an IR cable from your local Fluke distributor or directly from Fluke via Fluke Order Services at 800-993-5853. Outside the US, the IR cable can be ordered from your local Fluke distributor or from your local Fluke service center.
  • Distributor part Number: IR189USB
  • Fluke Service Center part Number: 2428108
    (price is $40.80 at time of posting).

Once you have received your cable you will need to return to download the firmware. Or save yourself some time and bookmark this page today to download firmware when you get it.

Click on the appropriate link above based on if you purchased a 287 or 289 meter. To get the update you will need to register your product and then you will be provided with update instructions.

These upgrades keep your meter on the cutting edge of technology and increase the functionally of your meter.

GPL Offer

 
Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us page.
How can I help you today?