Fluke CNX™ Ti125 Industrial System

Model#: TI125 CNX KIT Part#: 4362590 UPC#: 0 95969 67703 5
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 24.29ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke CNX™ Ti125 Industrial System 1
  • Fluke CNX™ Ti125 Industrial System 2
  • Fluke CNX™ Ti125 Industrial System 3
  • Fluke CNX™ Ti125 Industrial System 4
Discontinued

Key features

Get all the information you need to quickly troubleshoot problems with the Fluke Ti125 CNX Industrial Kit.

The Ti125 Offers:

  • IR-Fusion® with AutoBlend- blends a digital and partially transparent IR image into a single image, making problem detection fast and easy.
  • Exclusive IR-OptiFlex™ focus system—ensures that images are in good focus from 1.2 meters (4 feet) and beyond for optimum image clarity and scanning convenience. For shorter distances change to manual mode with the touch of a finger.
  • IR-PhotoNotes™ annotation system—Quickly identify and keep track of inspection locations by adding digital images of important information and surrounding areas.
  • Multi-mode video recording—focus-free video in visible light and infrared with full IR-Fusion.
  • Easily communicate the location of problems with the Electronic Compass (8-Point Cardinal).
The CNX™ i3000 iFlex AC Wireless Current Module Offers:
  • True-rms AC current measurements to 2500 A
  • 3% accuracy
  • Memory recording up to 65,000 readings
  • iFlex® current probe allows you to get into tight, awkward spaces
  • Backlit LCD display
  • CAT III 1000, CAT IV 600 V
  • IP42
This product is discontinued or reclassified

Product overview: Fluke CNX™ Ti125 Industrial System

Get all the information you need to quickly troubleshoot problems with the Fluke CNX™ Ti125 Industrial System. Easily view both voltage and current readings simultaneously from a remote test point with your Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to five critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!

Specifications: Fluke CNX™ Ti125 Industrial System

Fluke Ti125 Infrared Camera
Detailed Specifications
IR resolution (FPA size) 160 x 120 FPA Uncooled Microbolometer
Spectral band 7.5 μm to 14 μm (long wave)
Capture or refresh rate 9 Hz or 30 Hz versions
NETD (thermal sensitivity) ≤ 0.10 °C at 30 °C target temp (100 mK)
 0.10 °C at 30 °C target temp (100 mK)
FOV (field of view) 22.5 °H x 31 °V
IFOV (spatial resolution) 3.39 mRad
Temperature measurement range (not calibrated below -10  °C) -20 °C to +350 °C (-4 °F to +662 °F)
Temperature measurement accuracy ± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Focus mechanism IR-OptiFlex™ focus system
IR-Fusion® technology PIP, FULL IR, FULL VISIBLE, AutoBlend™
CNX™ wireless enabled Yes
Color alarms High temperature, low temperature, isotherm
Standard palettes Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Ultra Contrast™ palettes Blue-red, grayscale, inverted grayscale, high-contrast, hot metal, ironbow, amber, inverted amber
Hot/cold markers Yes
User definable spot markers Three on camera and in SmartView®
Centerbox (MIN/AVG/MAX) Yes
Level and span control Manual and auto
Minimum span in auto mode 5 °C
Minimum span in manual mode 2.5 °C
Minimum IR focus distance 15.25 cm (6 in)
Weight 0.726 kg (1.6 lb)
Size 28.4 x 8.6 x 13.5 cm (11.2 x 3.4 x 5.3 in)
LCD display 3.5 inch diagonal (portrait format)
Visible camera 2 megapixel industrial-grade
Minimum automatic parallax correction ~18-22 inches
IR-PhotoNotes™ annotation system Yes (3 images)
Laser pointer Yes
Torch Yes
Electronic (cardinal) compass Yes
Emissivity correction Yes
Transmission correction Yes
Background (reflected) compensation Yes
Voice annotation (audio) Yes (60 seconds) per image
Multi-mode video output Streaming USB video output (infrared, visible and IR-Fusion modes)
Multi-mode video recording (standard avi w/ mpeg encoding) Yes (AVI with MPEG encoding, up to 5 minutes)
Multi-mode video recording (radiometric .Is3) Yes, radiometric .is3 for approx. 2.5 to 5 minutes depending upon thermal scene
Memory review Thumbnail review
Battery (field-replaceable, rechargeable) Two
Battery life 4+ hours (each)*
External battery charging base Yes
Charging power supply Yes
Drop test 2 meter (6.5 feet)
Ingress protection (IP) rating (IEC 60529) IP 54
Recommended calibration cycle Two-years
Multifunction card reader Included
Memory storage 2 GB SD memory card
Direct download capability Mini USB download direct to PC
Operating temperature range -10 °C to +50 °C (14 °F to 122 °F)
Storage temperature range -20 °C to +50 °C (-4 °F to 122 °F)
Operating humidity Operating and storage 10 % to 95 %, non-condensing
Vibration and shock 2G, IEC 68-2-26 and 25G, IEC 68-2-29
Safety standards CSA (US and CAN): C22.2 No. 61010-1-04, UL: UL STD 61010-1 (2nd Edition), ISA: 82.02.01
C Tick IEC/EN 61326-1
EMI, RFI, EMC EN61326-1; FCC Part 5
User manuals Czech, English, Finnish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, Turkish, Dutch, and Hungarian
Standard warranty period Two-years
Extended warranty and service plans Yes

*Assumes 50% brightness of LCD

CNX™ 3000 Wireless Multimeter

For all specifications: accuracy is specified for one year after calibration, at operating temperatures of 18 °C to 28 °C, with relative humidity at 0 % to 90 %. Accuracy specifications take the form of ± ([ % of Reading ] + [ Number of least significant digits ]).

Detailed Specifications
AC Voltage
Range ¹ Resolution Accuracy ² ³
45 Hz to 500 Hz 500 Hz to 1 kHz
600.0 mV 0.1 mV 1.0 % + 3 2.0 % + 3
6.000 V 0.001 V
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
Notes:
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale p to 500 V, decreasing linearly to crest factor < 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
DC Voltage, Continuity, Resistance, Diode Test and Capacitance
Function Range Resolution Accuracy
mV 600.0 mV 0.1 mV 0.09 % + 2
V 6.000 V 0.001 V 0.09 % + 2
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V 0.15 % + 2
Ω 600 Ω 1 Ω Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer.
Ω 600.0 Ω 0.1 Ω 0.5 % + 2
6.000 kΩ 0.001 kΩ 0.5 % + 1
60.00 kΩ 0.01 kΩ
60.00 kΩ 0.1 kΩ
600.0 kΩ 0.001 MΩ
50.00 MΩ 0.01 MΩ 1.5 % + 3
Diode test 2.000 V 0.001 V 1 % + 2
μF 1000 nF 1 nF 1.2 % + 2
10.00 μF 0.01 μF
100.0 μF 0.1 μF
9999 μF¹ 1 μF 10 % typical
Notes:
¹ In the 9999 μF range for measurements to 1000 μF, the measurement accuracy is 1.2 % + 2.
AC and DC Current
Function Range ¹ Resolution Accuracy
mA AC
(45 Hz to 1 kHz)
60.00 mA 0.01 mA 1.5 % + 3
400.0 mA ³ 0.1 mA
mA DC ² 60.00 mA 0.01 mA 0.5 % + 3
400.0 mA 0.1 mA
Notes:
¹ All AC current ranges are specified from 5 % of range to 100 % of range.
² Input burden voltage (typical): 400 mA input 2 mV/mA.
³ 400.0 mA accuracy specified up to 600 mA overload.
Frequency
Range Resolution Accuracy ¹
99.99 Hz 0.01 Hz 0.1 % + 1
999.9 Hz 0.1 Hz
9.999 kHz 0.001 kHz
99.99 kHz 0.01 kHz
Notes:
¹ Frequency is specified up to 99.99 kHz in volts and up to 10 kHz in amps.
Input Characteristics
Function Overload
Protection
Input Impedance
(nominal)
Common Mode Rejection Ratio (1 kΩ unbalance) Normal Mode Rejection
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC,
50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 60 dB, DC to 60 Hz
1100 V RMS > 10 MΩ < 100 pF > 120 dB at DC,
50 Hz or 60 Hz
> 60 dB at 50 Hz or 60 Hz
Open Circuit Test Voltage Full Scale Typical Short Circuit Current
1100 V RMS < 2.7 V DC To 6 MΩ: < 0.7 V DC
50 MΩ: < 0.9 V DC
< 350 mA
1100 V RMS < 2.7 V DC To 6 MΩ: 2.000 V DC < 1.1 mA
Function Overload Protection Overload
mA Fused, 44/100 A,
1000 V FAST Fuse
600 mA overload for 2 minutes maximum, 10 minutes rest minimum
MIN/MAX Recording
Function Accuracy
DC functions The specified accuracy of the measurement function ± 12 counts for changes > 350 mS in duration.
AC functions The specified accuracy of the measurement function ± 40 counts for changes > 900 mS in duration.
General Specifications
Maximum voltage between any terminal and earth ground 1000 V DC or AC RMS
Ω fuse protection from A inputs 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only
Display (LCD) Update rate: 4/sec
Volts, amps, ohms: 6000 counts
Frequency: 10,000 counts
Capacitance: 1,000 counts
Battery type Three AA Alkaline batteries, NEDA 15A IEC LR6
Battery life 300 hours minimum
Temperature Operating: -10 °C to 50 °C
Storage: -40 °C to 60 °C
Relative humidity 0 % to 90 % (0 °C to 35 °C)
0 % to 75 % (35 °C to 40 °C)
0 % to 45 % (40 °C to 50 °C)
Altitude Operating: 2,000 m
Storage: 12,000 m
Temperature coefficient 0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
Wireless frequency 2.4 GHz ISM Band 20 meter range
Size (HxWxL) 4.75 cm x 9.3 cm x 20.7 cm
(1.87 in x 3.68 in x 8.14 in)
Weight 340 g (12 oz)
Safety standards US ANSI: ANSI/ISA 61010-1 / (82.02.01): 3rd edition
CSA: CAN/CSA-C22.2 No 61010-1-12: 3rd edition
CE European: IEC/EN 61010-1:2010
Electromagnetic compatibility
EMI, RFI, EMC, RF
EN 61326-1:2006, EN 61326-2-2:2006
ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489
V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249
FCCID : T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP54
Notes:
• Accuracy is specified as ± ([% of reading] + [number of least significant digits]).
• All ranges are autoranging.
• Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

Fluke CNX™ i3000 iFlex AC Wireless Current Module

Specifications
Range 2500 A AC
Resolution 0.1 A to 999.9, 1A from 1000 to 2500
Accuracy 3 % ± 5 digits
Crest factor (50 Hz/60 Hz) 3.0 at 1100 A, 2.5 at 1400 A, 1.42 at 2500 A, add 2 % for C.F. > 2
Display 3-1/2 digits, LCD w/backlight
Log rate/interval 1 sec minimum/adjustable by PC or front panel
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity 90 % at 35 °C
75 % at 40 °C
45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV
EN/IEC 61010-2-030:2010
EN/IEC 610101-2-031:2002
EN/IEC 61010-2-032:2002
Pollution degree 2
Temperature coefficient Add 0.1 X (specified accuracy) / °C per °C (<18 °C or >28 °C)
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)
Jaw opening 25.4 cm (10 in) coil

Fluke CNX™ v3000 AC Wireless Voltage Module

Accuracy is specified as ± ([% of reading] + [number of least significant digits]). All ranges are autoranging. Accuracy is specified from 5 % to 100 % of the range obtained by autoranging, from 18 °C to 28 °C.

AC Voltage
Range ¹ Resolution Accuracy ² ³
45  Hz to 500 Hz 500 Hz to 1 kHz
6.000 V 0.001 V 1.0 % + 3 2.0 % + 3
60.00 V 0.01 V
600.0 V 0.1 V
1000 V 1 V
Notes:
¹ All AC voltage ranges are specified from 1 % of range to 100 % of range.
² Crest factor of ≤ 3 at full scale up to 500 V, decreasing linearly to crest factor ≤ 1.5 at 1000 V.
³ For non-sinusoidal waveforms, add –(2 % of reading + 2 % full scale) typical, for crest factor up to 3.
General Specifications
LCD w/backlight 3½ digits, 6000 counts, updates 4/sec
Battery type 2 AA, NEDA 15 A, IEC LR6
Battery life 400 hours
Memory Record up to 65,000 readings
Unbound listen interval 5 seconds
RF communications 2.4 GHZ ISM Band
RF communication range 20 Meters
Operating temperature -10 °C to +50 °C
Storage temperature -40 °C to +60 °C
Operating humidity 90 % at 35 °C, 45 % at 40 °C, 45 % at 50 °C
EMC EN 61326-1:2006
Safety compliance EN/IEC 61010-1:2010 to 1000 V Measurement Category (CAT) III
600 V Measurement Category (CAT) IV EN/IEC 61010-2-030:2010
EN/IEC 61010-031:2002+A1:2008
Pollution degree 2
Temperature coefficient 0.1 X (specified accuracy) / °C (< 18 °C or > 28 °C)
Safety rating CAT IV 600 V, CAT III 1000 V
Certifications CSA, FCC T68-FWCS IC:6627A-FWCS
Ingress Protection (IP) rating IP42
Size (HxWxD) 16.5 cm x 6.35 cm x 3.56 cm (6.5 in x 2.5 in x 1.4 in)
Weight .22 kg (8 oz)

Models: Fluke CNX™ Ti125 Industrial System

TI125 CNX KIT
Get all the information you need to quickly troubleshoot problems with the Fluke CNX™ Ti125 Industrial System. 
Part#: 4362590
UPC#: 0 95969 67703 5
Easily view both voltage and current readings simultaneously from a remote test point with your Ti125 thermal imaging camera. Use the modules as stand-alone measurement tools or combine to capture up to five critical measurements along with the infrared image. Simplify and streamline your reporting with our easy to use SmartView® Software. Download the SmartView Mobile app and you can use your Apple® iPhone® or iPad® to generate a report and communicate your results directly to your client or colleague from the jobsite. Work smarter and faster!
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 21.94ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.52ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: Fluke CNX™ Ti125 Industrial System

Chat with ourFluke assistant
Clear Chat