Key features

  • Test charging states of EVSE with CP state simulation with the 12B ScopeMeter®.
  • Verify charging voltage and maximum available current using the 87V multimeter and TL224 test leads.
  • Check protective earth for correct wiring and functioning with the PE pre-test feature. 
  • Perform GFCI troubleshooting of EVSE and verify operation within safety standards. 
In stock
$ 4,299.99
FREE Shipping
30-day Returns

Product overview: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

Test the safety and performance of a type 1, level 1 or level 2 electric vehicle ac charging stations (EVSEs) with the Fluke FEV100, 87V + 125B ScopeMeter® kit. This kit includes the FEV100 test adapter to simulates the presence of an electrical vehicle. When connected to the test adapter, the 87V multimeter will allow you to monitor the output voltage and maximum charging current of the station. Verify EVSE charging states (vehicle simulation) by connecting the 125B ScopeMeter® to measure the control pilot signal output. With this kit, it's easy to verify an EV charging station is working properly after install and during periodic maintenance, or troubleshoot an EVSE if it is not delivering the appropriate charge. SAE J1772 compliant to North American standards.

EVSE installation safety and performance checks

  • PE PRE-TEST: Grounding system pre-test verifies that there is no presence of dangerous voltage at the ground terminal​.
  • GFCI TEST: Ground fault circuit interrupter test verifies the breaker of the EVSE is connected by detecting ground faults​.
  • PE ERROR: Ground fault simulation indicates an interruption of the ground conductor; the pending charging process is aborted, and new charging processes are prevented.
  • CP ERROR “E”: The standard J1772 defines Error “E” as a state when charging station is disconnected from vehicle, disconnected from utility, there is a loss of utility power or control pilot is short to control pilot reference (ground).
 

Virtual demo

What's in the box:

FEV100
  • Fluke FEV100/BASIC Test Adapter
  • Fluke FEV-CON/TY1 Type 1 Connector & Cable
  • Soft Carrying Case
  • User Manual
  • 3-year warranty

125B
  • Fluke 125B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • i400s AC Current Clamp
  • USB Angled Adapter
  • WiFi USB Adapter
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack

87V
  • Fluke 87V Industrial Multimeter
  • TL75 Test Leads (TL175 Eur)
  • AC175 Alligator Clips
  • Holster with tilt-leg, test lead storage
  • 80BK Temperature Probe
  • 9V Battery (Installed)

TL224
  • One pair (red, black) silicone insulated leads with one straight female coupler on one end and right angled on the other
  • One-year warranty
  • Quick Reference Guide

Specifications: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

Fluke FEV100 Electric Vehicle Charging Station Test Adapter specifications

Input voltage UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 208 V, 60 Hz (three-phase system) or UL1/N = 120 V, UL2/N = 120 V, UL1/L2 = 240 V, 60 Hz (single-phase system), ±10% voltage fluctuations from nominal
EV connector (EVC-13) SAE J1772 socket, 16 A (type 1, 5P single-phase)
Internal power consumption 2 W max.
Operating temperature -4 °F to 104 °F (-20 °C to 40 °C)
Storage temperature -4 °F to 122 °F (-20 °C to 50 °C)
Operating humidity range 10 % to 85 % relative humidity non-condensing
Storage relative humidity 0 % to 85 % non-condensing
Operating altitude 6561 ft (2000 m) max.
Dimensions (H × W × D) Approx. 8.66 x 4.33 x 1.77 in (220 x 110 × 45 mm) without cable assembly
Weight Approx. 4.4 lb (2 kg)
Safety standards IEC 61010-1, Pollution Degree 2
IEC 61010-2-030
Measurement category CAT II 250 V
IP protection class IP54
Electromagnetic Compatibility (EMC)
International IEC 61326-1: Basic Electromagnetic Environment
CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Functions
CP States A, B, C, D
CP Error “E” On/off
PE Error On/off
GFCI Test Yes, test resistor of 2 kΩ connected between L1 and PE, time limitation 40 ms
PE Pre-Test (typical) Visible indication >30 V on PE conductor
Outputs (for test purpose only)
Measuring terminals
L1, L2/N, PE
Max. 250 V 50/60 Hz, CAT II 250 V
CP signal output terminals Approx. ±12 V (under normal conditions), in case of wrong wiring or error of the charging station these terminals can be hazardous ≥ max. 250 V against PE
 

Fluke 120B Series Industrial ScopeMeter® Hand-Held Oscilloscopes Specification: Oscilloscope mode

Vertical
Frequency response - dc coupled Without probes and test leads (with BB120) 123B: dc to 20 MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads DC to 12.5 MHz (-3 dB) / dc to 20 MHz (-6 dB)
With VP41 10:1 Probe 123B: dc to 20MHz (-3 dB)
124B and 125B: dc to 40 MHz (-3 dB)
Frequency response - ac coupled (lf roll off) Without probes and test leads <10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads <10 Hz (-3 dB)
With VP41 10:1 Probe <10 Hz (-3 dB)
Rise time, excluding probes, 
test leads
123B <17.5 ns
124B and 125B <8.75 ns
Input impedance Without probes and test leads 1 MΩ//20 pF
With BB120 1 MΩ//24 pF
With STL120-IV 1:1 shielded test leads 1 MΩ//230 pF
With VP41 10:1 Probe 5 MΩ//15.5 pF
Sensitivity 5 mV to 200 V/div
Analog bandwidth limiter 10 kHz
Display modes A, -A, B, -B
Max. input voltage A and B Direct, with test leads, or with VP41 Probe 600 Vrms Cat IV, 750 Vrms maximum voltage.
With BB120 600 Vrms
Max. floating voltage, from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400Hz
Horizontal
Scope modes Normal, Single, Roll
Ranges (normal) Equivalent sampling 123B: 20 ns to 500 ns/div,
124B and 125B: 10 ns to 500 ns/div
Real time sampling 1 μs to 5 s/div
Single (real time) 1 μs to 5 s/div
Roll (real time) 1s to 60 s/div
Sampling rate (for both channels simultaneously) Equivalent sampling (repetitive signals) Up to 4 GS/s
Real time sampling 1 μs to 60 s/div 40 MS/s
 
Trigger
Screen update Free run, on trigger
Source A, B
Sensitivity A and B @ DC to 5 MHz 0.5 divisions or 5 mV
@ 40 MHz 123B: 4 divisions
124B and 125B: 1.5 divisions
@ 60 MHz 123B: N/A
124B and 125B: 4 divisions
Slope Positive, negative
 
Advanced scope functions
Display modes Normal Captures up to 25 ns glitches and displays analog-like persistence waveform
Smooth Suppresses noise from a waveform
Glitch off Does not capture glitches between samples
Envelope Records and displays the minimum and maximum of waveforms over time
Auto set (Connect-and-View™) Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level.
 
Dual input meter
The accuracy of all measurements is within ±(% of reading + number of counts) from 18 °C to 28 °C.
Add 0.1x (specific accuracy) for each °C below 18 °C or above 28 °C. For voltage measurements with 10:1 probe, add probe  uncertainty +1%. More than one waveform period must be visible on the screen.
 
Input A and input B
DC voltage (VDC)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy ±(0.5% +5 counts)
Common mode rejection (CMRR) >100 dB @ dc, >60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts
True-rms voltages (V ac and V ac+dc)
Ranges 500 mV, 5 V, 50 V, 500 V, 750 V
Accuracy for 5% to 100% of range (DC coupled) DC to 60 Hz (V ac+dc) ±(1% +10 counts)
1 Hz to 60 Hz (V ac) ±(1% +10 counts)
Accuracy for 5% to 100% of range (AC or dc coupled) 60 Hz to 20 kHz ±(2.5% +15 counts)
DC rejection (only VAC) >50 dB
Common mode rejection (CMRR) >100 dB @ dc
>60 dB @ 50, 60, or 400 Hz
Full scale reading 5000 counts, reading is independent of any signal crest factor.
Peak
Modes Max peak, Min peak, or pk-to-pk
Ranges 500 mV, 5 V, 50 V, 500 V, 2200 V
Accuracy Accuracy Max peak or Min peak 5% of full scale
Accuracy Peak-to-Peak 10% of full scale
Full scale reading 500 counts
Frequency (Hz)
Ranges 123B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz,1 MHz, 10 MHz, and 50 MHz
124B and 125B: 1 Hz, 10 Hz, 100 Hz, 1 kHz, 10 kHz, 100 kHz, 1 MHz, 10 MHz, and 70 MHz
Frequency range 15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy @1 Hz to 1 MHz ±(0.5% +2 counts)
Full scale reading 10,000 counts
RPM
Max reading 50.00 kRPM
Accuracy ±(0.5% +2 counts)
Duty cycle (PULSE)
Range 2% to 98%
Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse width (PULSE)
Frequency range 15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading 1000 counts
Amperes (AMP)
With current clamp Ranges Same as V dc, V ac, V ac+dc, or PEAK
Scale factors 0.1 mV/A, 1 mV/A, 10 mV/A, 100 mV/A, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy Same as V dc, V ac, V ac+dc, or PEAK (add current clamp uncertainty)
Temperature (TEMP) with optional temperature probe
Range 200 °C/div (200 °F/div)
Scale factor 1 mV/°C and 1 mV/°F
Accuracy As V dc (add temp. probe uncertainty)
Decibel (dB)
0 dBV 1 V
0 dBm (600 Ω /50 Ω) 1 mW referenced to 600 Ω or 50 Ω
dB on V dc, V ac, or Vac+dc
Full scale reading 1000 counts
Crest factor (CREST)
Range 1 to 10
Full scale reading 90 Counts
Phase
Modes A to B, B to A
Range 0 to 359 degrees
Resolution 1 degree
Power (125B only)
Configurations 1 phase / 3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Power factor (PF) Ratio between watts and VA range - 0.00 to 1.00
Watt RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes)
Full scale reading 999 counts
VA Vrms x Arms
Full scale reading 999 counts
VA reactive (var) √((VA)2-W2)
Full scale reading 999 counts
Vpwm
Purpose To measure on pulse width modulated signals, like motor drive inverter outputs
Principle Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency
Accuracy As Vrms for sinewave signals
 
Input A to common
Ohm (Ω)
Ranges 123B and 124B 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
125B 50 Ω, 500 Ω , 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ
Accuracy ±(0.6% + 5 counts) 50 Ω ±(2% + 20 counts)
Full scale reading 50 Ω to 5 MΩ - 5000 counts, 30 MΩ - 3000 counts
Measurement current 0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage <4 V
Continuity (Cont)
Beep <(30 Ω ±5 Ω) in 50 Ω range
Measurement current 0.5 mA
Detection of shorts of ≥1 ms
Diode
Measurement voltage @0.5 mA >2.8 V
@open circuit <4 V
Measurement current 0.5 mA
Polarity + on input A, - on COM
Capacitance (CAP)
Ranges 50 nF, 500 nF, 5 μF, 50 μF, 500 μF
Full scale reading 5000 counts
Measurement current 500 nA to 0.5 mA, increases with increasing ranges
 
Advanced meter functions
Zero Set Set actual value to reference
AutoHold (on A) Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals.
Fixed decimal point Activated by using attenuation keys
 
Cursor Readout (124B and 125B)
Sources A, B
Single vertical line Average, min and max readout
Average, min, max and time from start of readout (in ROLL mode; instrument in HOLD)
Min, max and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode.
Dual vertical lines Peak-peak, time distance and reciprocal time distance readout
Average, min, max and time distance readout (in ROLL mode; instrument in HOLD)
Dual horizontal lines High, low and peak-peak readout
Rise or fall time Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only 
possible in single channel mode)
Accuracy As oscilloscope accuracy
 
Recorder
The recorder captures meter readings in Meter Recorder mode or continuously captures waveform samples in Scope Recorder mode. The information is stored on internal memory or on optional SD card (with the 125B or 124B).
The results are displayed as Chart recorder display that plots a graph of min and max values of Meter measurements over time or as a waveform recorder display that plots all the captured samples.
Meter readings
Measurement Speed Maximum 2 measurement/s
Record Size (min, max, average) 2 M readings for 1 channel
Recorded Time Span 2 weeks
Maximum number of events 1024
Waveform record
Maximum sample rate 400 K sample/s
Size Internal memory 400 M samples Recorded Time
Span internal memory 15 minutes at 500 μs/div
11 hours at 20 ms/div
Record Size SD card 1.5 G samples
Recorded Time Span SD card 11 hours at 500 μs/div
14 days at 20 ms/div
Maximum number of events 64
 
Power Quality (125B only)
Readings Watt, VA, var, PF, DPF, Hz
Watt, VA, var ranges (auto) 250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (% r) ±(2% + 6 counts)
When selected: fundamental (% f) ±(4% + 4 counts)
DPF 0.00 to 1.00
PF 0.00 to 1.00, ±0.04
Frequency range 10.0 Hz to 15.0 kHz
40.0 Hz to 70.0 Hz
Number of Harmonics DC to 51
Readings / Cursor readings 
(fundamental 40 Hz to 70 Hz)
Vrms / Arms /Watt Each harmonic from fundamental maybe selected for individual readings
Includes frequency of fundamental, phase Angle and K-factor (in Amp and Watt)
 
BusHealth tester (Fluke 125B only)
Type Subtype Protocol
AS-i NEN-EN50295
CAN ISO-11898
Interbus S RS-422 EIA-422
Modbus RS-232 RS-232/EIA-232
RS-485 RS-485/EIA-485
Foundation Fieldbus H1 61158 type 1, 31.25 kBit
Profibus DP EIA-485
PA 61158 type 1
 
Miscellaneous
Display Type 5.7-inch color active matrix TFT
Resolution 640 x 480 pixels
Waveform Display Vertical 10 div of 40 pixels
Horizontal 12 div of 40 pixels
Power External Via Power Adapter BC430
Input voltage 10 V DC to 21 V DC
Power consumption 5 W typical
Input connector 5 mm jack
Internal Via Battery Pack BP290
Battery power Rechargeable Li-Ion 10.8 V
Operating time 7 hours with 50% backlight brightness
Charging time 4 hours with test tool off,  7 hours with test tool on
Allowable ambient temp 0 to 40 °C (32 to 104 °F) during charging
Memory Internal memory can store 20 data sets  (screen waveform and setup) Micro SD card slot with optional SD card  (max size of 32 GB)
Mechanical Size 259 x 132 x 55 mm 
(10.2 x 5.2 x 2.15 in)
Weight 1.4 kg (3.2 lb) including battery pack
Interface Optically isolated Transfer screen copies (bitmaps), settings and data
USB to PC/laptop OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®.
Optional WiFi adapter Fast transfer of screen copies (bitmaps), settings and data to PC/laptop, tablet, smartphone, etc. A USB port is provided for attaching the WiFi dongle. Do not use the USB port with a cable for safety reasons.
Environmental
Environmental MIL-PRF-28800F, Class 2
Temperature Battery Operation 0 to 40 °C (32 to 104 °F)
Power Adapter Operation 0 to 50 °C (32 to 122 °F)
Storage -20 to 60 °C (-4 to 140 °F)
Humidity (Operating) @ 0 to 10 °C (32 to 50 °F) Non-condensing
@ 10 to 30 °C (50 to 86 °F) 95%
@ 30 to 40 °C (86 to 104 °F) 75%
@ 40 to 50 °C (104 to 122 °F) 45%
Storage @ -20 to 60 °C (-4 to 140 °F) Non-condensing
Altitude Operating at 3 km (10,000 feet) CAT III 600 V
Operating at 2 km (6,600 feet) CAT IV 600 V
Storage 12 km (40,000 feet)
EMC electromagnetic compatibility International IEC 61326-1: Industrial, CISPR 11:  Group 1, Class A
Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Wireless radio with adapter Frequency range 2412 MHz to 2462 MHz
Output power <100 mW
Enclosure protection IP51, ref: EN/IEC60529
Safety General IEC 61010-1: Pollution Degree 2
Measurement IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Max. input voltage input A and B Direct on input or with leads 600 Vrms CAT IV for derating
With Banana-to-BNC Adapter BB120 600 Vrms for derating
Max. floating voltage from any terminal to ground 600 Vrms Cat IV, 750 Vrms up to 400 Hz
 

Fluke 87V Industrial Multimeter Specifications

Voltage DC Maximum voltage 1000 V
Accuracy ±(0.05% + 1)
Maximum resolution 10 µV
Voltage AC Maximum voltage 1000 V
Accuracy ±(0.7% + 2) True RMS
AC bandwidth 20 kHz with low pass filter; 3 dB @ 1 kHz
Maximum resolution 0.1 mV
Current DC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(0.2% + 2)
Maximum resolution 0.01 µA
Current AC Maximum amps 10 A (20 A for 30 seconds maximum)
Amps accuracy ±(1.0% + 2) True RMS
Maximum resolution 0.1 µA
Resistance Maximum resistance 50 MΩ
Accuracy ±(0.2% + 1)
Maximum resolution 0.1 Ω
Capacitance Maximum capacitance 9,999 µF
accuracy ±(1% + 2)
Maximum resolution 0.01 nF
Frequency Maximum frequency 200 kHz
Accuracy ±(0.005% + 1)
Maximum resolution 0.01 Hz
Duty cycle Maximum duty cycle 99.9%
Accuracy ±(0.2% per kHz + 0.1%)
Maximum resolution 0.1%
Temperature measurement –200.0 °C – 1090 °C
–328.0 °F – 1994.0 °F
excluding probe
80 BK temperature probe –40.0 °C – 260 °C
–40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater
Conductance Maximum conductance 60.00 nS
Accuracy ±(1.0% + 10)
Maximum resolution 0.01 nS
Diode Range 3 V
Resolution 1 mV
Accuracy ±(2% + 1)
Duty cycle range Accuracy Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating temperature –20 °C to + 55 °C
Storage temperature –40 °C to + 60 °C
Humidity (without condensation) 0% – 90% (0 °C – 35 °C)
0% – 70% (35 °C – 55 °C)
Operating Altitude 2000 m
Safety Specifications
Overvoltage category EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency approvals CE, CSA, RCM
Mechanical and General Specifications
Size 201 x 98 x 52 mm (with holster)
Weight 355 g
624 g – with holster
Display Digital 6000 counts updates 4/sec.
19,999 counts in high–resolution mode
Analog 32 segments, updates 40/sec
Frequency 19,999 counts, updates 3/sec at > 10 Hz
Warranty Lifetime
Battery Life Alkaline ~400 hours typical, without backlight
Shock 1 Meter drop per IEC 61010–1:2001
Vibration Per MIL–PRF–28800 for a Class 2 instrument

Models: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

FLK-FEV100/TY1 KIT2
Part#: 5348161
UPC#: 1 95112 04307 3
Includes:

FEV100
  • Fluke FEV100/BASIC Test Adapter
  • Fluke FEV-CON/TY1 Type 1 Connector & Cable
  • Soft Carrying Case
  • User Manual
  • 3-year warranty

125B
  • Fluke 125B Hand-Held Oscilloscope
  • Shielded Test Leads with Black Ground Leads
  • Test Lead Black (for Grounding)
  • Hook Clips (red, blue)
  • Banana-to-BNC Adapters (black, x1)
  • 10:1 Voltage Probe
  • i400s AC Current Clamp
  • USB Angled Adapter
  • WiFi USB Adapter
  • Switch Mode Power Supply, Adapter/Battery Charger
  • Rechargeable Li-ion Battery Pack

87V
  • Fluke 87V Industrial Multimeter
  • TL75 Test Leads (TL175 Eur)
  • AC175 Alligator Clips
  • Holster with tilt-leg, test lead storage
  • 80BK Temperature Probe
  • 9V Battery (Installed)

TL224
  • One pair (red, black) silicone insulated leads with one straight female coupler on one end and right angled on the other
  • One-year warranty
  • Quick Reference Guide
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 172.65ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.58ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: Fluke eMobility Tools Kit with FEV100 Test Adapter, 125B ScopeMeter®, 87V Multimeter and Test Leads

Chat with ourFluke assistant
Clear Chat