Fluke 393 FC Solar Kit with TLPV1 and TLPV2 Test Leads

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 157.45ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • F-FLK-393FC-TLPV-01a
  • F-393fc_61a_h
  • F-393fc_30a_h
  • F-393fc_64a_h
  • F-TLPV-UTOOL-03a

Key features

  • CAT III 1500 V rated clamp meter and MC4 leads
  • Measure DC current, voltage, and power on PV systems
  • Includes TLPV1 and TLPV2 MC4 solar test leads
  • Ideal for live-system solar troubleshooting
  • Fluke Connect® compatible for wireless logging

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
$1,093.99
FREE Shipping
30-day Returns

Product overview: Fluke 393 FC Solar Kit with TLPV1 and TLPV2 Test Leads

Built for safer, faster solar diagnostics.

The FLK-393FC-TLPV Solar Clamp Meter Kit is built for solar professionals who need fast, safe, and reliable troubleshooting on energized photovoltaic (PV) systems. Combining the trusted Fluke 393 FC Solar Clamp Meter with TLPV1 and TLPV2 CAT III 1500 V MC4 test leads, this kit delivers a complete solution for electrical measurements across solar installations.

Designed specifically for high-voltage DC environments, the 393 FC allows technicians to measure DC current up to 999.9 A, along with voltage and DC power, making it ideal for troubleshooting strings, combiner boxes, inverters, and other PV system components. The clamp-first workflow enables quick current checks without disconnecting conductors, helping technicians diagnose issues faster while minimizing downtime.

The included TLPV1 and TLPV2 MC4 lead sets expand the kit beyond clamp-only measurements, allowing inline voltage and electrical testing directly at MC4 connections. Both the clamp meter and leads carry a CAT III 1500 V safety rating, providing a consistent high-voltage solution designed for modern solar applications.

Built to withstand demanding field environments, the FLK-393FC-TLPV supports routine maintenance, commissioning, and troubleshooting workflows for residential, commercial, and utility-scale solar systems. Fluke Connect® compatibility also enables wireless measurement logging and data capture for streamlined reporting and documentation.

Whether you are validating system performance, locating faults, or performing preventive maintenance, the FLK-393FC-TLPV delivers the safety, capability, and convenience needed to keep PV systems operating efficiently.

What's in the box:

  • Fluke 393 FC CAT III 1500 V TRMS clamp meter
  • Test leads, CAT III 1500 V rated, right angle plugs, with safety caps
  • iFlex 18 inch flexible current probe
  • TPAK magnetic hanging strap
  • Premium carrying case for the 393 FC
  • TLPV1 MC4 to 4mm Test Lead Set
  • TLPV2 Solar Clamp Test Lead Set, Black/Red
  • TLPV-UTOOL Solar PV Connector Unlocking Tool (2)

Specifications: Fluke 393 FC Solar Kit with TLPV1 and TLPV2 Test Leads

Fluke 393 FC Solar Clamp Meter CAT III 1500 V

General specifications
Maximum voltage between any terminal and earth ground1000 V AC
1500 V DC
Batteries2 AA IEC LR6 alkaline
DisplayDual display with backlight
Automatic power off20 minutes
Electrical specifications
AccuracyAccuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature coefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC current: jaw
Range999.9 A
Resolution0.1 A
Accuracy2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)2.5 @ 600.0 A
3.0 @ 500.0 A
1.42 @ 999.9 A
Add 2 % for C.F. >2
AC current: flexible current probe
Range999.9 A
2500 A
Resolution0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz)2.5 @ 1400 A
3.0 @ 1100 A
1.42 @ 2500 A
Add 2 % for C.F. >2

Position sensitivity

Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %
B0.8 in (20.3 mm2.0 in (50.8 mm± 1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC current
Range999.9 A
Resolution0.1 A
Accuracy2 % RD + 5 digits[1]
[1]When using the ZERO function to compensate for offsets.
AC voltage
Range600.0 V
1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz)
DC voltage
Range600.0 V
1500 V
Resolution0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy1 % RD + 5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1 % RD + 5 digits
Amps frequency: jaw
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger level5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps frequency: flexible current probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger level5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage frequency
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger level5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC power
Range600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution0.1 kVA
1 kVA
Accuracy2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance
Range600.0 Ω
6000 Ω
60.00 kΩ
Resolution0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy1 % RD + 5 digits
Capacitance
Range100.0 μF
1000 μF
Resolution0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy1 % RD + 5 digits
Inrush trigger level5 A
Mechanical specifications
Size (L x W x H)281 mm x 84 mm x 49 mm
Weight (with batteries)520 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length (head to electronics connector)1.8 m
Environmental specifications
Operating temperature-10 °C to 50 °C
Storage temperature-40 °C to 60 °C
Operating humidityNon-condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Ingress Protection (IP) Rating 
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast and Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
GeneralIEC 61010-1, Pollution Degree 2
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless radio
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range2400 MHz to 2483.5 MHz
Output power<100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address: fluke.com/en-us/support/declaration-of-conformity.

Fluke TLPV1 MC4 to 4mm Test Lead Set

Ratings
VoltageComplies to IEC / EN 61010-031
CAT III 1500 V
Do Not Disconnect Under Load
Not Intended for Permanent Installation
Current30 A
Temperature Range+5 °C to +30 °C (+41 °F to +86 °F), < 80 % RH
+31 °C to +40 °C (+88 °F to +104 °F), < 50 % RH

Fluke TLPV2 Solar Clamp Test Lead Set, Black/Red

Ratings
VoltageComplies to IEC/EN61010-031
CAT III 1500V
Do Not Disconnect Under Load
Not intended to use for Permanent Installation
Current30A
Temperature Range+5 °C to +30 °C (+41 °F to +86 °F), <80 % RH +31 °C to +40 °C (+88 °F to +104 °F), <50 % RH
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 122.59ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.31ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat