Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads
Key features
- PV DMM electrical and irradiance test solution
- CAT III 1500 V rated DMM and MC4 test leads
- Includes Fluke Irradiance Meter for PV validation
- Ideal for commissioning and performance testing
- Advanced diagnostics for high-voltage PV systems
Sale ends soon.
Shop now!
Product overview: Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads
Product overview: 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads
Smarter solar diagnostics in the field.
The FLK-283FC-IRR-TLPV Solar Diagnostic Kit delivers a complete solution for photovoltaic (PV) commissioning, troubleshooting, and performance verification. Combining the Fluke 283 FC/PV Solar Digital Multimeter, Fluke Irradiance Meter, and TLPV1 and TLPV2 CAT III 1500 V MC4 test leads, this kit gives solar professionals the electrical and environmental measurement tools needed to evaluate PV system performance with confidence.
Designed for modern high-voltage solar installations, the 283 FC/PV supports measurements up to 1500 V DC, enabling technicians to troubleshoot modules, strings, combiner boxes, disconnects, and inverters safely and accurately. The included TLPV MC4 lead sets provide direct access to MC4 connections for fast inline voltage and electrical testing across the PV system.
The addition of the Fluke Irradiance Meter expands the kit beyond electrical diagnostics by adding key environmental measurements such as solar irradiance, module temperature, tilt, and orientation. Together, these measurements help technicians validate system output, compare electrical performance against site conditions, and identify potential issues impacting efficiency.
Built-in self-check functionality and limit gauge support on the 283 FC/PV multimeter helps improve measurement confidence and streamline troubleshooting workflows in the field. Both the multimeter and test leads carry CAT III 1500 V safety ratings, providing a consistent testing solution designed specifically for solar applications.
Whether commissioning new installations, troubleshooting underperforming arrays, or performing preventive maintenance, the FLK-283FC-IRR-TLPV helps technicians work faster, safer, and with greater diagnostic capability. Its rugged Fluke construction and solar-focused functionality make it an ideal all-in-one kit for professional PV testing and validation.
What's in the box:
283 FC TRMS Wireless Digital Multimeter
a283 FC 60A TRMS Wireless AC/DC Current Clamp
TLPV1 MC4 to 4mm Test Lead Set
TLPV2 Solar Clamp Test Lead Set, Black/Red
TL175-HV TwistGuard™ Silicone test leads
Premium carrying case for the 283 FC
Magnetic hanging strap
TLPV-UTOOL Solar PV Connector Unlocking Tool (2)
FLK-IRR2-BT Solar Irradiance Meter
FLK80PR-IRR External Temperature Probe with Suction Cup
MB1-IRR Mounting Bracket
Carrying Case with Shoulder Strap for the IRR2-BT
AA Alkaline Batteries (4)
Specifications: Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads
Fluke 393 FC Solar Clamp Meter CAT III 1500 V
| General specifications | ||||||||||||||||||||||
| Maximum voltage between any terminal and earth ground | 1000 V AC 1500 V DC | |||||||||||||||||||||
| Batteries | 2 AA IEC LR6 alkaline | |||||||||||||||||||||
| Display | Dual display with backlight | |||||||||||||||||||||
| Automatic power off | 20 minutes | |||||||||||||||||||||
| Electrical specifications | ||||||||||||||||||||||
| Accuracy | Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). | |||||||||||||||||||||
| Temperature coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C | |||||||||||||||||||||
| AC current: jaw | ||||||||||||||||||||||
| Range | 999.9 A | |||||||||||||||||||||
| Resolution | 0.1 A | |||||||||||||||||||||
| Accuracy | 2 % + 5 digits (10 Hz to 100 Hz) 2.5 % + 5 digits (100 Hz to 500 Hz) | |||||||||||||||||||||
| Crest Factor (50/60 Hz) | 2.5 @ 600.0 A 3.0 @ 500.0 A 1.42 @ 999.9 A Add 2 % for C.F. >2 | |||||||||||||||||||||
| AC current: flexible current probe | ||||||||||||||||||||||
| Range | 999.9 A 2500 A | |||||||||||||||||||||
| Resolution | 0.1 A (≤999.9 A) 1 A (≤2500 A) | |||||||||||||||||||||
| Accuracy | 3 % RD + 5 digits (10 Hz to 500 Hz) | |||||||||||||||||||||
| Crest Factor (50/60Hz) | 2.5 @ 1400 A 3.0 @ 1100 A 1.42 @ 2500 A Add 2 % for C.F. >2 | |||||||||||||||||||||
Position sensitivity ![]() |
| |||||||||||||||||||||
| DC current | ||||||||||||||||||||||
| Range | 999.9 A | |||||||||||||||||||||
| Resolution | 0.1 A | |||||||||||||||||||||
| Accuracy | 2 % RD + 5 digits[1] [1]When using the ZERO function to compensate for offsets. | |||||||||||||||||||||
| AC voltage | ||||||||||||||||||||||
| Range | 600.0 V 1000 V | |||||||||||||||||||||
| Resolution | 0.1 V (≤600.0 V) 1 V (≤1000 V) | |||||||||||||||||||||
| Accuracy | 1 % RD + 5 digits (20 Hz to 500 Hz) | |||||||||||||||||||||
| DC voltage | ||||||||||||||||||||||
| Range | 600.0 V 1500 V | |||||||||||||||||||||
| Resolution | 0.1 V (≤600.0 V) 1 V (≤1500 V) | |||||||||||||||||||||
| Accuracy | 1 % RD + 5 digits | |||||||||||||||||||||
| mV dc | ||||||||||||||||||||||
| Range | 500.0 mV | |||||||||||||||||||||
| Resolution | 0.1 mV | |||||||||||||||||||||
| Accuracy | 1 % RD + 5 digits | |||||||||||||||||||||
| Amps frequency: jaw | ||||||||||||||||||||||
| Range | 5.0 Hz to 500.0 Hz | |||||||||||||||||||||
| Resolution | 0.1 Hz | |||||||||||||||||||||
| Accuracy | 0.5 % RD + 5 digits | |||||||||||||||||||||
| Trigger level | 5 Hz to 10 Hz, ≥10 A 10 Hz to 100 Hz, ≥5 A 100 Hz to 500 Hz, ≥10 A | |||||||||||||||||||||
| Amps frequency: flexible current probe | ||||||||||||||||||||||
| Range | 5.0 Hz to 500.0 Hz | |||||||||||||||||||||
| Resolution | 0.1 Hz | |||||||||||||||||||||
| Accuracy | 0.5 % RD + 5 digits | |||||||||||||||||||||
| Trigger level | 5 Hz to 20 Hz, ≥25 A 20 Hz to 100 Hz, ≥20 A 100 Hz to 500 Hz, ≥25 A | |||||||||||||||||||||
| Voltage frequency | ||||||||||||||||||||||
| Range | 5.0 Hz to 500.0 Hz | |||||||||||||||||||||
| Resolution | 0.1 Hz | |||||||||||||||||||||
| Accuracy | 0.5 % RD + 5 digits | |||||||||||||||||||||
| Trigger level | 5 Hz to 20 Hz, ≥5 V 20 Hz to 100 Hz, ≥5 V 100 Hz to 500 Hz, ≥10 V | |||||||||||||||||||||
| DC power | ||||||||||||||||||||||
| Range | 600.0 kVA (600.0 V dc range) 1500 kVA (1500 V dc range) | |||||||||||||||||||||
| Resolution | 0.1 kVA 1 kVA | |||||||||||||||||||||
| Accuracy | 2 % RD + 2.0 kVA 2 % RD + 20 kVA | |||||||||||||||||||||
| Resistance | ||||||||||||||||||||||
| Range | 600.0 Ω 6000 Ω 60.00 kΩ | |||||||||||||||||||||
| Resolution | 0.1 Ω (≤600.0 Ω) 1 Ω (≤6000 Ω) 0.01 kΩ (≤60.00 kΩ) | |||||||||||||||||||||
| Accuracy | 1 % RD + 5 digits | |||||||||||||||||||||
| Capacitance | ||||||||||||||||||||||
| Range | 100.0 μF 1000 μF | |||||||||||||||||||||
| Resolution | 0.1 μF (≤100.0 μF) 1 μF (≤1000 μF) | |||||||||||||||||||||
| Accuracy | 1 % RD + 5 digits | |||||||||||||||||||||
| Inrush trigger level | 5 A | |||||||||||||||||||||
| Mechanical specifications | ||||||||||||||||||||||
| Size (L x W x H) | 281 mm x 84 mm x 49 mm | |||||||||||||||||||||
| Weight (with batteries) | 520 g | |||||||||||||||||||||
| Jaw opening | 34 mm | |||||||||||||||||||||
| Flexible current probe diameter | 7.5 mm | |||||||||||||||||||||
| Flexible current probe cable length (head to electronics connector) | 1.8 m | |||||||||||||||||||||
| Environmental specifications | ||||||||||||||||||||||
| Operating temperature | -10 °C to 50 °C | |||||||||||||||||||||
| Storage temperature | -40 °C to 60 °C | |||||||||||||||||||||
| Operating humidity | Non-condensing (<10°C) ≤90 % RH (at 10 °C to 30 °C) ≤75 % RH (at 30 °C to 40 °C) ≤45 % RH (at 40 °C to 50 °C) | |||||||||||||||||||||
| Operating altitude | 2000 m | |||||||||||||||||||||
| Storage altitude | 12,000 m | |||||||||||||||||||||
| Ingress Protection (IP) Rating | ||||||||||||||||||||||
| Electromagnetic Compatibility (EMC) | ||||||||||||||||||||||
| International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |||||||||||||||||||||
| Korea (KCC) | Class A equipment (Industrial Broadcast and Communications Equipment) Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |||||||||||||||||||||
| USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. | |||||||||||||||||||||
| Safety | ||||||||||||||||||||||
| General | IEC 61010-1, Pollution Degree 2 | |||||||||||||||||||||
| Measurement | IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V | |||||||||||||||||||||
| Wireless radio | ||||||||||||||||||||||
| Radio frequency certification | FCC ID: T68-FBLE, IC: 6627A-FBLE | |||||||||||||||||||||
| Wireless radio frequency range | 2400 MHz to 2483.5 MHz | |||||||||||||||||||||
| Output power | <100 mW | |||||||||||||||||||||
| SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. The full text of the EU declaration is available at the following Internet address: fluke.com/en-us/support/declaration-of-conformity. | ||||||||||||||||||||||
Fluke TLPV1 MC4 to 4mm Test Lead Set
| Ratings | |
| Voltage | Complies to IEC / EN 61010-031 CAT III 1500 V Do Not Disconnect Under Load Not Intended for Permanent Installation |
| Current | 30 A |
| Temperature Range | +5 °C to +30 °C (+41 °F to +86 °F), < 80 % RH +31 °C to +40 °C (+88 °F to +104 °F), < 50 % RH |
Fluke TLPV2 Solar Clamp Test Lead Set, Black/Red
| Ratings | |
| Voltage | Complies to IEC/EN61010-031 CAT III 1500V Do Not Disconnect Under Load Not intended to use for Permanent Installation |
| Current | 30A |
| Temperature Range | +5 °C to +30 °C (+41 °F to +86 °F), <80 % RH +31 °C to +40 °C (+88 °F to +104 °F), <50 % RH |
The FLK-283FC-TLPV Solar Digital Multimeter Kit is designed for solar professionals who need advanced electrical troubleshooting capability on high-voltage photovoltaic (PV) systems.
Models: Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads
283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads
UPC#: 1 95112 17236 0
283 FC TRMS Wireless Digital Multimeter
a283 FC 60A TRMS Wireless AC/DC Current Clamp
TLPV1 MC4 to 4mm Test Lead Set
TLPV2 Solar Clamp Test Lead Set, Black/Red
TL175-HV TwistGuard™ Silicone test leads
Premium carrying case for the 283 FC
Magnetic hanging strap
TLPV-UTOOL Solar PV Connector Unlocking Tool (2)
FLK-IRR2-BT Solar Irradiance Meter
FLK80PR-IRR External Temperature Probe with Suction Cup
MB1-IRR Mounting Bracket
Carrying Case with Shoulder Strap for the IRR2-BT
AA Alkaline Batteries (4)