Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads

Model#: FLK-283FC-IRR-TLPVPart#: 6162791UPC#: 1 95112 17236 0
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 117.32ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • F-FLK-283FC-IRR-TLPV-01a
  • F-283FC-Voltron-EMEA-apps-198
  • F-283FC-Voltron-EMEA-apps-344
  • flk-283fc-irr-tlpv_c
  • F-TLPV-UTOOL-03a

Key features

  • PV DMM electrical and irradiance test solution
  • CAT III 1500 V rated DMM and MC4 test leads
  • Includes Fluke Irradiance Meter for PV validation
  • Ideal for commissioning and performance testing
  • Advanced diagnostics for high-voltage PV systems

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
$1,729.99
FREE Shipping
30-day Returns

Product overview: Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads

Product overview: 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads

Smarter solar diagnostics in the field.

The FLK-283FC-IRR-TLPV Solar Diagnostic Kit delivers a complete solution for photovoltaic (PV) commissioning, troubleshooting, and performance verification. Combining the Fluke 283 FC/PV Solar Digital Multimeter, Fluke Irradiance Meter, and TLPV1 and TLPV2 CAT III 1500 V MC4 test leads, this kit gives solar professionals the electrical and environmental measurement tools needed to evaluate PV system performance with confidence.

Designed for modern high-voltage solar installations, the 283 FC/PV supports measurements up to 1500 V DC, enabling technicians to troubleshoot modules, strings, combiner boxes, disconnects, and inverters safely and accurately. The included TLPV MC4 lead sets provide direct access to MC4 connections for fast inline voltage and electrical testing across the PV system.

The addition of the Fluke Irradiance Meter expands the kit beyond electrical diagnostics by adding key environmental measurements such as solar irradiance, module temperature, tilt, and orientation. Together, these measurements help technicians validate system output, compare electrical performance against site conditions, and identify potential issues impacting efficiency.

Built-in self-check functionality and limit gauge support on the 283 FC/PV multimeter helps improve measurement confidence and streamline troubleshooting workflows in the field. Both the multimeter and test leads carry CAT III 1500 V safety ratings, providing a consistent testing solution designed specifically for solar applications.

Whether commissioning new installations, troubleshooting underperforming arrays, or performing preventive maintenance, the FLK-283FC-IRR-TLPV helps technicians work faster, safer, and with greater diagnostic capability. Its rugged Fluke construction and solar-focused functionality make it an ideal all-in-one kit for professional PV testing and validation.

What's in the box:

283 FC TRMS Wireless Digital Multimeter
a283 FC 60A TRMS Wireless AC/DC Current Clamp
TLPV1 MC4 to 4mm Test Lead Set
TLPV2 Solar Clamp Test Lead Set, Black/Red
TL175-HV TwistGuard™ Silicone test leads
Premium carrying case for the 283 FC
Magnetic hanging strap
TLPV-UTOOL Solar PV Connector Unlocking Tool (2)
FLK-IRR2-BT Solar Irradiance Meter
FLK80PR-IRR External Temperature Probe with Suction Cup
MB1-IRR Mounting Bracket
Carrying Case with Shoulder Strap for the IRR2-BT
AA Alkaline Batteries (4)
 

Specifications: Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads

Fluke 393 FC Solar Clamp Meter CAT III 1500 V

General specifications
Maximum voltage between any terminal and earth ground1000 V AC
1500 V DC
Batteries2 AA IEC LR6 alkaline
DisplayDual display with backlight
Automatic power off20 minutes
Electrical specifications
AccuracyAccuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]).
Temperature coefficientsAdd 0.1 x specified accuracy for each °C > 28 °C or < 18 °C
AC current: jaw
Range999.9 A
Resolution0.1 A
Accuracy2 % + 5 digits (10 Hz to 100 Hz)
2.5 % + 5 digits (100 Hz to 500 Hz)
Crest Factor (50/60 Hz)2.5 @ 600.0 A
3.0 @ 500.0 A
1.42 @ 999.9 A
Add 2 % for C.F. >2
AC current: flexible current probe
Range999.9 A
2500 A
Resolution0.1 A (≤999.9 A)
1 A (≤2500 A)
Accuracy3 % RD + 5 digits (10 Hz to 500 Hz)
Crest Factor (50/60Hz)2.5 @ 1400 A
3.0 @ 1100 A
1.42 @ 2500 A
Add 2 % for C.F. >2

Position sensitivity

Distance from Optimumi2500-10 Flexi2500-18 FlexError
A0.5 in (12.7 mm)1.4 in (35.6 mm)± 0.5 %
B0.8 in (20.3 mm2.0 in (50.8 mm± 1.0 %
C1.4 in (35.6 mm)2.5 in (63.5 mm± 2.0 %
Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.
DC current
Range999.9 A
Resolution0.1 A
Accuracy2 % RD + 5 digits[1]
[1]When using the ZERO function to compensate for offsets.
AC voltage
Range600.0 V
1000 V
Resolution0.1 V (≤600.0 V)
1 V (≤1000 V)
Accuracy1 % RD + 5 digits (20 Hz to 500 Hz)
DC voltage
Range600.0 V
1500 V
Resolution0.1 V (≤600.0 V)
1 V (≤1500 V)
Accuracy1 % RD + 5 digits
mV dc
Range500.0 mV
Resolution0.1 mV
Accuracy1 % RD + 5 digits
Amps frequency: jaw
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger level5 Hz to 10 Hz, ≥10 A
10 Hz to 100 Hz, ≥5 A
100 Hz to 500 Hz, ≥10 A
Amps frequency: flexible current probe
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger level5 Hz to 20 Hz, ≥25 A
20 Hz to 100 Hz, ≥20 A
100 Hz to 500 Hz, ≥25 A
Voltage frequency
Range5.0 Hz to 500.0 Hz
Resolution0.1 Hz
Accuracy0.5 % RD + 5 digits
Trigger level5 Hz to 20 Hz, ≥5 V
20 Hz to 100 Hz, ≥5 V
100 Hz to 500 Hz, ≥10 V
DC power
Range600.0 kVA (600.0 V dc range)
1500 kVA (1500 V dc range)
Resolution0.1 kVA
1 kVA
Accuracy2 % RD + 2.0 kVA
2 % RD + 20 kVA
Resistance
Range600.0 Ω
6000 Ω
60.00 kΩ
Resolution0.1 Ω (≤600.0 Ω)
1 Ω (≤6000 Ω)
0.01 kΩ (≤60.00 kΩ)
Accuracy1 % RD + 5 digits
Capacitance
Range100.0 μF
1000 μF
Resolution0.1 μF (≤100.0 μF)
1 μF (≤1000 μF)
Accuracy1 % RD + 5 digits
Inrush trigger level5 A
Mechanical specifications
Size (L x W x H)281 mm x 84 mm x 49 mm
Weight (with batteries)520 g
Jaw opening34 mm
Flexible current probe diameter7.5 mm
Flexible current probe cable length (head to electronics connector)1.8 m
Environmental specifications
Operating temperature-10 °C to 50 °C
Storage temperature-40 °C to 60 °C
Operating humidityNon-condensing (<10°C)
≤90 % RH (at 10 °C to 30 °C)
≤75 % RH (at 30 °C to 40 °C)
≤45 % RH (at 40 °C to 50 °C)
Operating altitude2000 m
Storage altitude12,000 m
Ingress Protection (IP) Rating 
Electromagnetic Compatibility (EMC)
InternationalIEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments.
Korea (KCC)Class A equipment (Industrial Broadcast and Communications Equipment)
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
USA (FCC)47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
Safety
GeneralIEC 61010-1, Pollution Degree 2
MeasurementIEC 61010-2-032: CAT III 1500 V / CAT IV 600 V
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V
Wireless radio
Radio frequency certificationFCC ID: T68-FBLE, IC: 6627A-FBLE
Wireless radio frequency range2400 MHz to 2483.5 MHz
Output power<100 mW
SIMPLIFIED EU DECLARATION OF CONFORMITY
Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU.
The full text of the EU declaration is available at the following Internet address: fluke.com/en-us/support/declaration-of-conformity.

Fluke TLPV1 MC4 to 4mm Test Lead Set

Ratings
VoltageComplies to IEC / EN 61010-031
CAT III 1500 V
Do Not Disconnect Under Load
Not Intended for Permanent Installation
Current30 A
Temperature Range+5 °C to +30 °C (+41 °F to +86 °F), < 80 % RH
+31 °C to +40 °C (+88 °F to +104 °F), < 50 % RH

Fluke TLPV2 Solar Clamp Test Lead Set, Black/Red

Ratings
VoltageComplies to IEC/EN61010-031
CAT III 1500V
Do Not Disconnect Under Load
Not intended to use for Permanent Installation
Current30A
Temperature Range+5 °C to +30 °C (+41 °F to +86 °F), <80 % RH +31 °C to +40 °C (+88 °F to +104 °F), <50 % RH

The FLK-283FC-TLPV Solar Digital Multimeter Kit is designed for solar professionals who need advanced electrical troubleshooting capability on high-voltage photovoltaic (PV) systems.

Models: Fluke 283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads

FLK-283FC-IRR-TLPV

283 FC/PV Solar Kit with IRR2-BT, TLPV1 and TLPV2 Test Leads

Part#: 6162791
UPC#: 1 95112 17236 0

283 FC TRMS Wireless Digital Multimeter
a283 FC 60A TRMS Wireless AC/DC Current Clamp
TLPV1 MC4 to 4mm Test Lead Set
TLPV2 Solar Clamp Test Lead Set, Black/Red
TL175-HV TwistGuard™ Silicone test leads
Premium carrying case for the 283 FC
Magnetic hanging strap
TLPV-UTOOL Solar PV Connector Unlocking Tool (2)
FLK-IRR2-BT Solar Irradiance Meter
FLK80PR-IRR External Temperature Probe with Suction Cup
MB1-IRR Mounting Bracket
Carrying Case with Shoulder Strap for the IRR2-BT
AA Alkaline Batteries (4)

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 120.76ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 24.11ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat