Fluke BT5300 Series Battery Tester
Model#: Fluke BT5310 Part#: 5319188 UPC#: 1 95112 03640 2
Key features
- Higher Accuracy: 18 ppm accuracy for DC voltage; 0.2% accuracy for AC internal resistance
- Faster speed: 4 sampling speeds: Ex-Fast (10ms), Fast (20ms), Medium (100ms), and Slow (200ms); Scan mode - average 100 ms per channel
- More stable performance: can be used conjunction with SW9010 multiplexer cards with special loop design, reducing the effects of eddy current, improving immunity
- More load capacity: support the allowable total line resistance ≥ 10 Ω (for 3 mΩ measurement range), ≥20 Ω (for 30 mΩ or higher measurement range)
- More functions - built-in high-z mode for enclosure potential measurement
- High compatibility: support LAN and RS232 interface, and command set compatible with the similar products
- More friendly interface: 4.3-inch LCD screen, intuitive user interface
Product overview: Fluke BT5300 Series Battery Tester
Fluke BT5300 Serial is tailored for battery sorting.
Three-in-one instrument - a high-accuracy battery tester, a 6.5/7.5-digit voltmeter and Multiplexer Cards, compact and efficient. 7 performance improvements - User interface, accuracy, speed, stability, compatible command set, allowable total line resistance, enclosure potential measurement.
Specifications: Fluke BT5300 Series Battery Tester
Specifications | |
Functions | ACR, DCV, enclosure potential measurement |
Measurement method | AC 4-wire method (1 kHz) |
Rated input | DC ±11V |
Input impedance | 10 MΩ, high-z (>10 GΩ) |
Sampling speed | Ex-Fast, Fast, Medium, Slow |
Allowable total line resistance | ≤ 10Ω @ 3 mΩ measurement range |
≤ 20Ω @ other measurement ranges | |
Trigger | Internal/external |
Trigger delay | ON/OFF, Delay time: 0 to 9.999 s |
Average | ON/OFF, Average count: 2 to 16 |
Measurement storage | Up to 512 sets |
Channel extension | Internal: Up to 2 SW9010 multiplexer cards can be added for up to 64 channels (BT5311 and BT5321 only) External: Up to 256 channels by using SW1080 switch mainframe |
External interface | RS-232C , LAN |
Other functions | Contact check |
Sampling Time | |
Sampling speed: ACR and DCV simultaneously | Sampling time (50Hz/60Hz) |
Ex-Fast | 10 ms / 8.3 ms |
Fast | 20 ms / 16.7 ms |
Medium | 100 ms / 83.3 ms |
Slow | 200 ms / 166.7 ms |
Measurement Range and Accuracy | |||||
ACR measurement | |||||
Range | 3 mΩ | 30 mΩ | 300 mΩ | 3 Ω | 10 Ω |
Max. Display value | 5.0000 mΩ | 50.000 mΩ | 500.00 mΩ | 5.0000 Ω | 15.000 Ω |
Resolution | 0.1 µΩ | 1 µΩ | 10 µΩ | 100 µΩ | 1 mΩ |
Test current1 | 100/200/300 mA² | 100 mA | 10 mA | 1 mA | 1 mA |
Test current frequency | 1 kHz ± 1Hz | ||||
Accuracy³ | 0.2% * rdg + 6 dgt | ||||
Temperature coefficient (< 18 °C or > 28 °C) | (0.05% * rdg + 0.005% * F.S.) / °C | ||||
Response time (Pure resistance) | < 20 ms | ||||
1. Test current error ±10% | |||||
2. For 3 mΩ range, slow sampling rate, the accuracy for different test current 100mA 0.5% * rdg + 20 dgt 200mA 0.3% * rdg + 12 dgt 300mA 0.2% * rdg + 6 dgt | |||||
3. With the different sampling speed, extra error need to be added 3mΩ range Ex-fast: ±30 dgt; Fast: ±10 dgt; Medium: ±5 dgt 30mΩ to 10 Ω range Ex-fast: ±3 dgt; Fast: ±2 dgt; Medium: ±2 dgt |
DCV measurement | ||
BT5310/BT5311 | BT5320/BT5321 | |
Digit | 6.5 digits | 7.5 digits |
Range | 10 V | |
Max. Display value | ±11.00000V | ±11.000000V |
Resolution | 10 µV | 1 µV |
Accuracy1 | 25 ppm * rdg + 50 µV | 18 ppm * rdg + 25 µV |
Response time (typical) | < 20 ms | < 20 ms |
Temperature coefficient (<18 °C or >28°C) | (5 ppm * rdg + 1 ppm * F.S.) / °C | (1 ppm * rdg + 1 ppm * F.S.) / °C |
1 With the different sampling speed, extra error need to be added BT5310/BT5311 Ex-Fast: ±50 µV; Fast: ±30 µV; Medium: ±10 µV BT5320/BT5321 Ex-Fast: ±50 µV; Fast: ±20 µV; Medium: ±5 µV |
Model Comparison | ||||
Features | BT5310 | BT5311 | BT5320 | BT5321 |
DCV resolution | 6.5 digit | 7.5 digit | ||
Add SW9010 Multiplexer Cards to the inside of the Instrument | No | Yes. Up to 2 cards | No | Yes. Up to 2 cards |
Connect the external SW1080 Switch Mainframe | Yes | Yes | Yes | Yes |
General Specifications | |
Dimensions (W x H x L) | BT5300 Battery Tester: 216 mm x 133 mm x 383 mm |
SW1080 Switch Mainframe: 430mm x 128 mm x 260 mm | |
SW9010 Multiplexer Card: 202 mm x 26 mm x 222 mm | |
Weight | BT5300 Battery Tester: 7.3 kg (Without SW9010) |
SW1080 Switch Mainframe: 9 kg (Without SW9010) | |
SW9010 Multiplexer Card: 500 g | |
Display | 4.3-inch TFT LCD, resolution 480 x 272 |
Operation temperature | 0 °C to +40 °C |
Storage temperature | -10 °C to +50 °C |
Operation temperature | Non-condensing (<10°C) |
≤90% RH (at 10 °C to 30 °C) | |
≤75% RH (at 30 °C to 40 °C) | |
≤45% RH (at 40 °C to 50 °C) | |
Altitude | 3000 m |
Storage altitude | 12000 m |
Rated voltage | AC 100V to 240V (Auto-selection) |
Rated frequency | 50/60Hz |
Rated power | 60 VA |
Safety | IEC 61010-1: Pollution Degree 2 |
EMC | IEC 61326-1: Industrial |
Warranty | BT5300 Battery Tester: 3 years SW1080 Switch Mainframe: 3 years SW9010 Multiplexer Card: 1 year Note: Relays, fuses and connectors are not covered by warranty. |
Models: Fluke BT5300 Series Battery Tester
Fluke BT5310
6.5-digit high-accuracy battery tester (Does not support built-in multiplexer card)
Part#: 5319188UPC#: 1 95112 03640 2
Includes:
- Fluke BT5310 Battery Tester main unit
- Power cord
- USB-232 serial cable
- Safety Information
- Calibration report
Fluke BT5311
6.5-digit high-accuracy battery tester (supports built-in multiplexer card)
Part#: 5319195UPC#: 1 95112 03641 9
Includes:
- Fluke BT5311 Battery Tester main unit
- Power cord
- USB-232 serial cable
- Safety Information
- Calibration report
Fluke BT5320
7.5-digit high-accuracy battery tester (Does not support built-in multiplexer card)
Part#: 5319206UPC#: 1 95112 03642 6
Includes:
- Fluke BT5320 Battery Tester main unit
- Power cord
- USB-232 serial cable
- Safety Information
- Calibration report
Fluke BT5321
7.5-digit high-accuracy battery tester (supports built-in multiplexer card)
Part#: 5319214UPC#: 1 95112 03643 3
Includes:
- Fluke BT5321 Battery Tester main unit
- Power cord
- USB-232 serial cable
- Safety Information
- Calibration report