Key features

  • Automatic pressure generation and regulation to 1000psi
  • Replaceable pressure control modules
  • Built-in test templates, one-key calibration
  • HART communication
  • Pressure leakage testing
  • Automatic fine-pressure adjustment, automatic pressure stabilization
  • Powerful, replaceable Li-ion battery
  • Quick pressure release valve with a muffler
  • Extend measurement range with 750P Series pressure modules
  • Measure temperature with 720RTD probe
  • Bright dual-three-channel /color graphic display
  • Weight <5kg
  • Rugged and portable design with standard 3-year warranty
  • Absolute and gage pressure modules up to 7MPa.
  • Use the modules to change the Fluke 729Pro to a different output pressure range
In stock
$14,687.99
FREE 75th Anniversary Shipping
30-day Returns

Product overview: Fluke 729 Pro Automatic Pressure Calibrator

Fluke 729 Pro Automatic Pressure Calibrator not only simplifies pressure calibration but saves time, reduces errors and improves accuracy. With plug-in replaceable pressure control modules and pressure generation and regulation up to 1000psi, 7Mpa.

Specifications: Fluke 729 Pro Automatic Pressure Calibrator

Key parameters729 Pro 7M729 Pro 4M
Pressure control range-13 to 1000 psi, -90 to 7000 kPa,
-0.90 to 70 bar
-13 to 600 psi, -90 to 4000 kPa,
-0.90 to 40 bar
Pressure typeGauge/absolute (Depends on the type of internal or external pressure module
Pressure accuracy and Control stability0.02% of FS, 0.005% of FS
Replaceable pressure measurement modulesYes, 6 modulesYes, 4 modules
mA sourcing/measurementYes
Voltage measurementYes
Loop power24 V dc
Pressure switch testingYes
Pressure leakage testingYes
HART CommunicationYes, basic commands supported
Autostep / auto rampYes (with customizable speed, mode and style)
BatteryRechargeable lithium battery with charge indication (charged in the instrument or separately)
LanguageEnglish
Electrical specification
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range.
Ranges
mA measure, source and simulate0 mA to 24 mA
Volts dc measurement0 V dc to 30 V dc
Resolution
mA dc source, simulate and measure1 μA
Voltage dc measurement1 mV
Accuracy0.01% FS ±2 LSD all ranges (at 23 °C ±5 °C)
Stability20 ppm FS /°C (-10 °C to +18 °C and 28 °C to 50 °C)
mA simulation working voltage12 V dc to 30 V dc
Loop compliance voltage24 V dc @ 20 mA
Temperature measurement , 100 Ω Pt(385) RTD-50 °C to 150 °C
Temperature resolution0.01 °C
Temperature accuracy±0.1 °C ±0.25 °C combined uncertainty when using 720 RTD probe (optional accessory)
Drive capability (mA source)1200 Ω (without HART resistor), 950 Ω (with internal HART resistor)
Mechanical specification
Dimension (HxWxL)290 x 215 x100 mm, (4.3 x 4.4 x 9.4 in)
Weight4.9 kg, (10.8 lbs)
Environmental specification
Operating temperature-10 °C to 50 °C
Pressure control0 °C to 50 °C
Battery charging0 °C to 40 °C
Storage temperature-20 °C to 60 °C
Operating altitude<3000 m
Storage altitude<13000 m
Operating humidityNon-condensing (<10°C)
≤90 % RH (10 °C to 30 °C)
≤75 % RH (30 °C to 40 °C)
≤45 % RH (40 °C to 50 °C)
Pressure Module Selection Table
Pressure modulePressure typeRangeResolutionOverall uncertainty729Pro 4M729Pro 7M
FLK-PMM-200KGauge(-15 to 30) psi0.0001 psi0.02 % FS / year, maximum
(-100 to 200) kPa0.001 kPa
(-1 to 2) bar0.00001 bar
FLK-PMM-200KAAbsolute(0 to 30) psi0.0001 psi0.05 % FS / year, maximum
(0 to 200) kPa0.001 kPa
(0 to 2) bar0.00001 bar
FLK-PMM-2000KGauge(-13 to 300) psi0.001 psi0.02 % FS / year, maximum
(-90 to 2000) kPa0.01 kPa
(-0.90 to 20) bar0.0001 bar
FLK-PMM-4000KGauge(-13 to 600) psi0.01 psi0.02 % FS / year, maximum
(-90 to 4000) kPa0.01 kPa
(-0.90 to 40) bar0.0001 ba
FLK-PMM-7000KGauge(-13 to 1000) psi0.01 psi0.02 % FS / year, maximum 
(-90 to 7000) kPa0.01 kPa
(-0.90 to 70) bar0.0001 ba
FLK-PMM-7000KAAbsolute(0 to 1000) psi0.01 psi0.02 % FS / year, maximum 
(0 to 7000) kPa0.01 kPa
(0 to 70) bar0.0001 ba
Dry air or non-corrosive gases only / 15 °C to 35 °C, all ranges

Models: Fluke 729 Pro Automatic Pressure Calibrator

FLK-729PRO 4M
Fluke 729 Pro Automatic Pressure Calibrator 600 psi
Part#: 5300476
UPC#: 1 95112 03090 5
  • FLK-PMM-4000K
  • FLK-PMM-200K (Optional)
  • FLK-PMM-200KA (Optional)
  • FLK-PMM-2000K (Optional)
FLK-729PRO 7M
Fluke 729 Pro Automatic Pressure Calibrator 1000 psi
Part#: 5300483
UPC#: 1 95112 03091 2
  • FLK-PMM-7000K
  • FLK-PMM-200K (Optional)
  • FLK-PMM-200KA (Optional)
  • FLK-PMM-2000K (Optional)
  • FLK-PMM-4000K (Optional)
  • FLK-PMM-7000KA (Optional)
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 48.81ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.06ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Welcome to Fluke's Chat GPT Assistant. As with other generative AI systems, this chatbot may occasionally generate incorrect information. For questions regarding the safe use of Fluke tools, please refer to your owners manual. You must comply with your employer’s safety standards and obtain necessary training before using Fluke tools or taking electrical measurements. To speak with a person, visit our Contact Us page.
How can I help you today?