Key features

  • Uncertainty: ± 0.01% for single channel, ± 0.008% for dual channel.
  • Single or dual channel with parallel measurement mode for increased reliability.
  • Interfaces: Includes RS232 and IEEE-488.

Product overview: RPM4 BA100K Reference Pressure Barometer

The RPM4 BA100K is a full function laboratory quality barometer intended to measure atmospheric pressure with the very highest performance. Its outstanding pressure measurement specifications are made possible by DHI's exclusive quartz reference pressure transducer (Q-RPT) modules.

Specifications: RPM4 BA100K Reference Pressure Barometer

 RPM4 BA100K (Single Channel)RPM4 BA100K/BA100K (Dual Channel)
Range70 kPa to 110 kPa (10 psia to 16 psia)
Power requirements85 V ac to 264 V ac, 50/60 Hz; 12 V dc, 1.2 A (battery)
Weight5 kg (11 lb)
Dimensions (H x W x D)10 cm x 22.7 cm x 24 cm (3.9 in. x 8.9 in. x 9.5 in.)
Test port connections1/8 in NPT F
Communications portsRS232 (COM1, COM2), IEEE-488.2 Resolution To 1 ppm, user adjustable To 1 ppm, user
ResolutionTo 1 ppm, user adjustable
Operating temperature15 °C to 35 °C (59 °F to 95 °F)
Warm up time30 minute temperature stabilization recommended from cold power up
VibrationMeets MIL-T-28800D
Predicted Stability1± 0.005 % of reading± 0.0032 % of reading
Precision2± 0.008 % of reading± 0.006 % of reading
Measurement Uncertainty3± 0.01 % of reading± 0.008 % of reading
1Predicted Q-RPT measurement stability limit (k=2) over one year assuming regular use of AutoZero function. AutoZero is performed by the operator by comparison with a barometric reference in absol mode. Absolute mode predicted one year stability without AutoZ is: Single Channel ± (5 Pa + 0.005 % of reading), D Channel ± (4 Pa + 0.0032 % of reading).
2Combined linearity, hysteresis, repeatability.
3Maximum deviation of the Q-RPT indication from the true value of applied spressure including precision, predicted one year stability limit, temperature effect and calibration uncertainty, combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.”

Models: RPM4 BA100K Reference Pressure Barometer

RPM4 mhhhac/mlllac
Reference Pressure Monitor

Where:
mhhhac indicates the Hi Q-RPT designation.
c indicates Q-RT class (s for Standard, p for Premium)

mlllac indicates the Lo Q-RPT designation and class. Leave blank if there is no Lo Q-RPT.

See Q-RPT and ranges table under Features for available Q-RPTs.
RPM4 04
-1 US units version, -2 SI units version

RPM4 05
CE mark

RPM4 06
Special calibration

RPM4 07
Special test fluid, Hi Q-RPT (specify fluid)

RPM4 08
Special test fluid, Lo Q-RPT (specify fluid)

RPM4 09
-1 Special configuration, air data (A160K/A160K, A350K/A160K only)

RPM4-LP
Low Pressure Monitor, -15 to 15 kPa (-60 to 60 inH2O)

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 43.74ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.66ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.

Manuals + resources: RPM4 BA100K Reference Pressure Barometer

Chat with ourFluke assistant
Clear Chat