English

Amprobe UAT-505 Underground Utilities Locator Kit

Model#: Amprobe UAT-505 Part#: 5258663 UPC#: 1 95112 01496 7
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 23.82ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned; HTTP status code of 404 was returned;
  • Amprobe UAT-505 Underground Utilities Locator Kit
  • Amprobe UAT-505 Underground Utilities Locator Kit
  • Amprobe UAT-505 Underground Utilities Locator Kit
  • Amprobe UAT-505 Underground Utilities Locator Kit
  • Amprobe UAT-505 Underground Utilities Locator Kit

Key features

  • Locate underground energized and de-energized wires and cables
  • Locate underground metal pipes
  • 33 kHz transmitting frequency: best frequency for general locating
  • Measure depths up to 20 ft
In stock
$4,896.99
FREE Shipping
30-day Returns

Product overview: Amprobe UAT-505 Underground Utilities Locator Kit

The Amprobe UAT-505 Underground Utility Locator Kit is a rugged, economical solution for locating underground energized and de-energized wires, cables and pipes. The Transmitter utilizes the proven 33 kHz frequency, which is ideal for most locating applications. With the Receiver, trace the signal in Induction or Direct Test Leads Connection Modes. The Receiver features fast sound and meter response and easy depth measurements to 20 feet at the push of a button, as well as highly sensitive Power and Radio Modes which detect energized wires and radio signals on underground lines.

Expert tracing features for any situation

The UAT-505 can be used in different modes for optimal tracing in many situations.

Receiver

  • Power Mode locates energized wires with a 50/60 Hz frequency. The Receiver alone detects the electromagnetic fields emitted by buried energized lines conducting currents.
  • Radio Mode uses the Receiver to detect radio waves coming from cellular towers, radio stations, etc. that are picked up and carried by underground metal objects, such as cables or pipes.

Receiver and transmitter

  • Induction Mode uses the Transmitter to wirelessly induce a signal into a buried pipe, cable, or wire. The Receiver then detects the signal carried by the buried utility.
  • In Direct Test Leads Connection Mode, the Transmitter is connected to the buried de-energized cables or utilities with test leads (provided there is an available access point to the utility). The Transmitter then sends a signal across the wire or pipe.
  • If it is not possible to gain access to a cable for making an electrical contact or it is not safe to do so, the optional Signal Clamp provides an efficient and safe method of applying a locate signal to a cable.

Note: The UAT-505 can also trace non-metallic pipes in Induction or Direct Test Leads Connection Modes. Some of these pipes have embedded metal trace that will conduct signal for tracing. For pipes without embedded metal, use a conductive tracing tape.

Note: The UAT-500-T Transmitter should never be connected to an energized circuit. The Amprobe UAT-600-T Transmitter, safety rated CAT IV 600 V, can be safely used to connect to energized circuits.

Specifications: Amprobe UAT-505 Underground Utilities Locator Kit

UAT-500-T Transmitter 
Operating voltageDe-energized circuit only for Direct Connection Mode
Transmitting frequency33 kHz
Tracing modesDe-energized:
- Induction Mode
- Direct Connection Mode
- Clamp Mode
Transmitting mode power outputMax. 1 watt
Output voltageMax. 35 V rms
Output currentMax. 100 mA rms
Visual signal indicationTwo LEDs indicating LO and HI signal
Audio signal indicationContinuous Signal Mode: Continuous audio tone
Pulse Signal Mode: Fast pulsed audio tone
Compatible receiverUAT-600-R Receiver
Compatible accessoriesSC-600 Signal Clamp
TL-UAT-500 Test lead set
Operating temperature and humidity'-4 °F to 122 °F (-20 °C to 50 °C), ≤ 80% RH
Storage temperature and humidity'-40 °F to 140 °F (-40 °C to 60 °C), ≤ 80% RH
Operating altitude< 6561 ft (< 2000 m)
Pollution degree2
IP-ratingIP54
Power supplyFour (4) 1.5 V D cell alkaline batteries
Battery lifeApprox. 12 hours at 70 °F (21 °C) (Typical)
Low battery indicationBoth LO and HI LEDs blink every 1.5 seconds and audio sound pulses every
1.5 seconds
Agency approvalAgency approval
Safety complianceIEC 61010-1, CSA/UL 61010-1,
IEC 61010-031, CSA/UL 61010-031 (test leads)
Electromagnetic CompatibilityIEC 61326-1 Korea (KCC): Class A Equipment (Industrial Broadcasting &
Communication Equipment) [1]
[1] This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This equipment
is intended for use in business environments and is not to be used in homes.
Size (H x W x L)Approx. 18.1 x 3.5 x 2.6 in (460 x 90 x 65 mm)
WeightApprox. 3.9 lb (1.77 kg) (batteries installed)
  
  
UAT-600-R Receiver 
Operating voltage0 to 600 V
Tracing modesActive tracing: 33 kHz (32,768 Hz) and 8 kHz (8,192 Hz)
Passive tracing: 50 / 60 Hz and Radio
Locating modesPeak and Null
Sensitivity adjustment
(gain control)
Yes
Depth measurementUp to 6 m (20 ft)
Depth measurement accuracy4 in (0.1 m) to 10 ft (3m): ± 3 %
10 ft (3 m) to 20 ft (6 m): ± 5 %
Sensitivity at 1 m (typical)Power: 2 mA
Radio: 20 μA
8 kHz: 5 μA
33 kHz: 5 μA
Display backlightAutomatic
Audio indicationIncreasing closer to the signal
Compatible transmitterUAT-600-T Transmitter
Display4.3 in (109 mm), 320 x 240 BW outdoor LC-Display with auto backlight
Update rateInstantaneous
Operating temperature and humidity'-4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH
Storage temperature and humidity'-40 °F to 140 °F (-40 °C to 60 °C), ≤ 90% RH
Operating altitude< 6561 ft (< 2000 m)
Pollution degree2
IP-ratingIP54
Drop proof3.28 ft (1 m)
Power supplySix (6) 1.5 V AA alkaline batteries
Auto power off15 minutes idle
Will auto turn off after 15 min of no button pressing
Battery lifeApprox. 35 hours at 70 °F (21 °C) (Typical)
Low battery indicationLow battery indication
Measurement CategoryCAT IV 600 V
Agency approvalAgency approval
Safety complianceIEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL 61010-2-033
Size (H x W x L)Approx. 11.9 x 4.7 x 30.7 in (302 x 120 x 779 mm)
WeightApprox. 4.2 lb (1.9 kg) (batteries installed)
  
  
TL-UAT-500 Test Leads 
Operating voltage and current50 V max, 1 A
Leads length11.5 ft (3.5 m)
Compatible transmitterUAT-500-T Transmitter
Operating temperature and humidity'-4 °F to 122 °F (-20 °C to 50 °C), ≤ 80% RH
Storage temperature and humidity'-40 °F to 140 °F (-40 °C to 60 °C), ≤ 80% RH
Operating altitude< 6561 ft (< 2000 m)
Pollution degree2
Agency approvalAgency approval
Safety complianceIEC 61010-031, CSA/UL 61010-031
Size (H x W x L)Approx. 9 x 3.5 x 3.1 in (230 x 90 x 80 mm)
WeightApprox. 1.1 lb (0.5 kg)
  
  
SC-600 Signal ClampNot included, optional accessory
Operating voltage & current0 to 600 V, 100 A max.
Operating frequency33 kHz (32,768 Hz) and 8 kHz (8,192 Hz)
Signal voltage output (nominal)23 V rms at 8 kHz
30 V rms at 33 kHz
Operating temperature and humidity'-4 °F to 122 °F (-20 °C to 50 °C), ≤ 90 % RH
Storage temperature and humidity'-40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH
Operating altitude< 6561 ft (< 2000 m)
Pollution degree2
IP-ratingIP54
Drop proof3.28 ft (1 m)
Measurement CategoryCAT IV 600 V
Agency approvalAgency approval
Safety complianceIEC 61010-1, IEC 61010-2-032
CSA/UL 61010-1, CSA/UL 61010-2-032
Electromagnetic CompatibilityIEC 61326-1 Korea (KCC): Class A Equipment (Industrial Broadcasting &
Communication Equipment) [1]
[1] This product meets requirements for industrial (Class A) electromagnetic
wave equipment and the seller or user should take notice of it. This
equipment is intended for use in business environments and is not to be
used in homes.
Size (H x W x L)Approx. 11.6 x 7.1 x 1.4 in (295 x 180 x 37 mm)
WeightApprox. 1.9 lb (0.85 kg)
  

Models: Amprobe UAT-505 Underground Utilities Locator Kit

Amprobe UAT-505
Amprobe UAT-505 Underground Utilities Locator Kit
Part#: 5258663
UPC#: 1 95112 01496 7
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 61.03ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.98ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Hi, I'm your virtual assistant, I will do my very best to help you navigate all things Fluke related. You can ask me anything! I'm new and might make a few mistakes. For safe use of Fluke tools, refer to the product manuals, safety sheets, and your company's safety requirements. To speak with a person, visit our Contact Us or Talk to Sales page. For information on how we handle personal data, see our Privacy Policy.