How to Test Solar Panels for Common Problems

Solar panels are a common choice for homeowners who want to be eco-friendly and cut energy costs. However, it's important to ensure that your solar modules are working efficiently to get the most out of them. In this article, we'll discuss solar module tests and how technicians fix common problems that affect their performance.

Learn why testing PV panels is important, how to use your DMM for testing solar panels, and what to look for when doing these tests.

How to Test Solar Panels with a Multimeter

A multimeter is a tool that measures the voltage, current, and resistance of an electrical circuit. Fluke recommends using the Fluke 117 Electrician's Multimeter or Fluke 283 FC CAT III 1500 V Digital Multimeter to test solar modules. Here's how a technician tests solar modules with a multimeter:

  1. Set the multimeter to DC voltage mode.
  2. To connect the multimeter, attach the red lead to the positive terminal of the solar module. Attach the black lead to the negative terminal.
  3. Place the solar module in direct sunlight or under a bright artificial light source.
  4. Take note of the voltage reading on the multimeter. The voltage output of a solar module should be within 10% of its rated output.
  5. If the voltage output is significantly lower than the rated output, it may indicate a problem with the module.

How to Test Solar Panels with an I-V Curve Tracer

An I-V curve tracer measures current and voltage output of a solar module in various conditions. Fluke recommends using the SMFT-1000 solar multifunction tool with the IRR2-BT irradiance and temperature sensor to test solar modules. Here's how a technician tests solar modules with an I-V curve tracer:

  1. Connect the I-V curve tracer to the solar module according to the manufacturer's instructions.
  2. Place the solar module in direct sunlight.
  3. Install the IRR2-BT irradiance meter according to the manufacturer’s instructions.
  4. Run the I-V curve test.
  5. The I-V curve tracer creates a graph displaying the module's current and voltage output in various situations.
  6. Analyze the graph to determine if the module performs within its specifications.

Is Your Solar Panel Working?

If your solar modules are not generating power, there may be a problem with one or more of the modules. Fluke suggests using a multimeter, clamp meter, or I-V curve tracer to check the voltage and current of each module. If one module's measurements decrease significantly compared to the others, it may indicate a problem. In such cases, you may need to replace the module.

Poor wiring connections can also affect the performance of your solar modules. Have the wiring connections between the modules, inverter, and battery inspected. Make sure all connections are secure and free of damage. Fluke suggests using the Fluke 376 FC Clamp Meter to measure solar module current and identify wiring issues.

If your solar modules are generating power but not charging the battery, the inverter may be the problem. Check the inverter's display for any error messages and consult the manufacturer's manual for troubleshooting steps. Fluke suggests using the Fluke 376 FC Clamp Meter to measure inverter current and identify problems.

In conclusion, having your solar modules tested is essential to ensure they are working correctly and generating maximum power. Fluke offers a range of products to help test solar modules and diagnose problems.

Fluke provides a range of tools to meet your needs and deliver accurate results. These tools include multimeters, clamp meters, and I-V curve tracers. They are reliable and provide precise measurements through their design.
 