Flowmeter calibration: Five best practices you need to know

Why calibrate flowmeters?
A flowmeter measures the rate that fluid or gas moves through it. Test and measurement professionals use them in a wide variety of applications where accurate flow measurements are critical, including (but not limited to) HVAC, energy and utilities, water management, aerospace, agriculture and the pharmaceutical industry. In applications like these, it’s important to calibrate the flowmeters that make the measurements. Regular calibrations assure you that the flowmeter’s measurements are as accurate as their specifications say they are.
Even the most rugged flowmeters can fall out of calibration. All instruments’ performance degrades over time; parts wear out or break. Flowmeters can be affected by corrosion or dirt within the media that flows through them. They may also be damaged by impact, variations in the process, or by improper installation.
Best practices for calibrating flowmeters
Standard best practices in calibration apply to flowmeter calibration as they do for all test equipment; flow calibration also has some specific best practices to keep in mind:
- The standard that you use to calibrate a flowmeter must be accurate enough to perform the calibration.
The general rule of thumb is that your standard should be four times more accurate than the device under test (DUT); however, this can vary depending on the requirements of the calibration.
- Your standard should be traceable to a recognized standard.
Traceability provides an unbroken chain of documentation that shows how the measurements it makes compare to even more accurate standards. Traceable measurements help you prove that your measurements are what your flowmeter says they are, within specific ranges.
- The rate of flow between the DUT and the calibration standard must be in a steady state.
Since the flow rate of the standard and the DUT are compared in real time during calibration, the system flow rate should not vary with time.
- All media measured by the calibration standard must also be measured by the flowmeter at the same time.
In other words, there should not be any leaks or significant temperature changes in intermediary volumes that might affect the measurement.
- You should perform the calibration under conditions that are typical of the flowmeter’s actual operation.
For example, the viscosity, density or heat content of the medium being measured can affect the flowmeter based on its operating technology. It is important to match the calibration with the flowmeter’s application.

Fluke Calibration molbloc/molbox gas flow calibration systems calibrate flowmeters and controllers over a wide range of flows. They can be fully automated with COMPASSTM for Flow software.
Keep learning
What is flow calibration?
Flow calibration is the foundational process of verifying and adjusting a flowmeter's accuracy to ensure its readings align with a known standard. This meticulous procedure is essential across diverse industries reliant on precise flow measurement, impacting everything from process efficiency and product quality to regulatory compliance and custody transfer applications.
Understanding the nuances of flow calibration is paramount for calibration professionals. It involves a deep dive into various methodologies, intricate standards, and the specific requirements of different flowmeter technologies.
Calibration ensures that the flowmeter's output signal accurately reflects the actual flow rate of a fluid (liquid or gas). This is achieved by comparing the flowmeter's readings against a reference standard of higher accuracy, often traceable to national standards like those maintained by NIST. Any deviations are then meticulously documented and corrected, bringing the flowmeter to the accepted standard.
What is the standard for flow calibration?
While a universal, one-size-fits-all standard for flow calibration remains elusive, a framework of best practices and recognized standards guides professionals in this field. The specific requirements often hinge on factors such as:
- Industry-Specific Regulations: Stringent regulations govern flow measurement in sectors like pharmaceuticals, food processing, and oil & gas, often necessitating compliance with specific standards (e.g., API, ISO, AGA).
- Application Criticality: Flowmeters used in custody transfer, where financial transactions depend on accurate measurement, demand higher accuracy and more rigorous calibration procedures than those used for general process monitoring.
- Flowmeter Technology: Diverse flowmeter technologies (Coriolis, ultrasonic, differential pressure, etc.) have unique characteristics influencing calibration methods and appropriate standards.
- Target Accuracy: The desired level of accuracy dictates the selection of calibration procedures and equipment and the acceptable uncertainty levels.
Despite these variations, some common threads weave through most flow calibration scenarios:
- NIST Traceability: Ensuring traceability to national standards like those maintained by NIST provides a reliable foundation for accurate and comparable measurements across different facilities and industries. This traceability chain is established through a hierarchy of standards, with each level calibrated against a higher-level standard.
- Primary Standards: Calibration often employs primary standards, such as weigh tanks, piston provers, or master meters, which provide highly accurate flow measurements with known uncertainties.
- Controlled Environments: Minimizing environmental influences on the flowmeter and the standard is crucial. Calibration laboratories maintain controlled temperature, pressure, and humidity to reduce measurement errors.
- Meticulous Documentation: Detailed records of the calibration process, including procedures, equipment used, environmental conditions, and results, are vital for quality assurance, audit trails, and demonstrating compliance.
By adhering to these standards and best practices, calibration professionals ensure the accuracy and reliability of flow measurement systems, supporting industrial efficiency, safety, and compliance.
- Flowmeter Calibration Landscape: A look at today’s calibration techniques & best practices in Flow Control Magazine.
- Flow Calibration Basics
- Selecting a Solution
Get help