Getting Started With Fluke Connect

Fluke Connect™ is a comprehensive mobile and web-based solution that collects, stores, and visualizes machine data from over 100 Fluke tools and sensors. It enables customers to remotely operate devices, view, save, and export measurements, and access live asset data anytime, anywhere — enhancing safety, efficiency, and decision-making.

Fluke Connect in use
Fluke Connect in Use

Whether you're on the plant floor, in the field, or managing assets remotely, Fluke Connect ensures your team stays productive, your equipment stays healthy, and your technicians stay safe.

Let’s explore the benefits of Fluke Connect, how to get started with the app, and key features you won’t want to miss.

How Does Fluke Connect Help My Team?

If you’ve ever struggled with disconnected data, outdated reports, or the inability to take and read measurements at a safe distance, Fluke Connect can help. It’s a free app that helps you centralize data from 100+ Fluke tools in one secure place.

You get:

  • Clarity, with accurate readings: Monitor up to 6 readings in real time while documenting photos and notes as proof of work.
  • Speed, with real-time recording and syncing: Securely share live data, store and access historical asset data, and identify trends.
  • Safety, with remote readings at a distance: Stand safely outside the arc flash zone while monitoring readings directly in the app.

Plus, trend logging lets your team monitor measurements, identify trends, and flag fluctuations or intermittent issues that a spot check might miss.

With all this data at your fingertips, you can stay on top of preventive maintenance, prioritize critical repairs, and minimize unplanned downtime.

Get Started: Connect, Capture, and Share With Fluke Connect

It’s time to connect, capture, and share real-time data in a smarter, safer way with Fluke Connect.

Step 1: Connect a Tool

To start, visit our website to download the Fluke Connect app for free.

Next, pick up one of the 100+ compatible Fluke tools, including digital multimeters, insulation testers, thermal imaging cameras, and more.

With the app open on your smart device, power on your Fluke tool. Then locate the Fluke Connect button: it’s the one with the WiFi symbol above the Fluke logo. Press the button and you’ll notice the same symbol appear on your tool’s display screen. This confirms that Bluetooth is enabled. At this point, your smart device will automatically add your Fluke tool to the app.

Step 2: Capture a Measurement

Once you’ve added tools to Fluke Connect, it’s easy to take your first reading. For a common example, let’s start with a clamp meter reading. 

As usual, be sure to practice all necessary safety precautions!

Walk up to a panel and connect your clamp meter, such as the Fluke 376 FC True-RMS Clamp Meter with iFlex, to one phase of the branch.

Next, step outside the arc flash zone, pull out your smart device, and open the Fluke Connect app. Click Connect and Capture Measurements to see a list of every tool connected to the app. 

In the device list, simply locate Fluke 376 FC and click on it to get a real-time reading. Now, you can monitor the current from a safer distance, view measurements in real time, and save measurements directly within the app.

This same process enables safer readings for other field tasks, including insulation resistance and solar lab testing.

Plus, with multi-device sync, you can capture readings from up to six tools simultaneously. Techs can monitor and save measurements from all these tools at once, even capturing voltage and current readings together on one screen. 

Step 3: Share with Your Team

While monitoring a reading, you can easily record, save, download, and live-share it with any team member. Sharing is easy: you can send notifications or emails directly from the app.

Plus, you can share much more than readings. With secure cloud storage, you can instantly download, sync, and share data spreadsheets (CSVs), photos (JPEGs), or notes (text files) across your team. This gives techs the flexibility to create comprehensive documentation for every asset while in the field. 

Top Fluke Connect Features

From live readings to trend logging, Fluke Connect does it all. 

  • Live Remote Readings: Collect real-time tool and equipment data safely and instantly.
  • Multi-Device Sync: Connect, measure, and record readings from up to 6 Fluke tools at once, even mixing and matching tool types, all on one screen.
  • Mobile Reporting: Create, save, and share professional reports directly from the field for comprehensive reporting and rapid collaboration. Capture measurements, notes, and even photos using your smart device, then sync and export them in CSV, text, or JPEG formats. You can even take photos and measurements simultaneously.
  • Secure Cloud-Based Storage: Organize, access, and protect measurement history with secure cloud storage. Features include offline access, seamless tool connectivity, and multi-device sync, all designed to keep your data safe and your workflows uninterrupted.
  • Data Trends and Graphs: Uncover intermittent issues through automated trend logging and graphing. Visualize and analyze data that spot checks might miss, enabling proactive maintenance and reducing unplanned downtime.
  • Remote Monitoring: Receive real-time alerts on abnormal asset behavior to respond quickly and reduce downtime.

Download Fluke Connect for Free

Did you know that Fluke Connect is free?

That’s right! There are no hidden fees or in-app purchases.

So if you haven’t downloaded the app yet, visit the Fluke Connect page to learn more and download the app today.