10 Steps To Starting an In-House Calibration Lab
Every organization that deals with measurement data – from data centers and pharmaceutical manufacturers to semiconductor plants – requires routine calibration of its measuring instruments to keep operations reliable and in top shape. Calibration, as defined in the International Vocabulary of Metrology (VIM), establishes the relationship between the values indicated by an instrument and those realized by reference standards, under specified conditions. Maintaining your measurement devices as close to original equipment manufacturer (OEM) specifications as possible ensures confidence in the measurements you use to inform everyday decisions. In turn, this accuracy keeps production quality high and reduces unnecessary waste or downtime in your facility.

But not all calibrations are created equal. Where you choose to get your tools adjusted matters. A calibration lab’s ability to account for factors like tool type, accuracy specifications, and turnaround time dictates whether that lab will suit your needs. An accredited calibration provider like the Fluke Calibration laboratory in Everett, Washington is an excellent choice for many of our customers. However, in some cases, a company may benefit from starting their own in-house calibration lab.
For example, if your team has custom process requirements or can’t afford long turnaround times from outside labs, an in-house calibration laboratory can be a worthwhile investment. Here, we’ll help you weigh the pros and cons of calibrating in house and discuss the most important steps to take when designing your own lab.
Why Start a Calibration Lab?
The initial costs of starting an in-house calibration lab may seem steep: You’ll likely have to buy new equipment, hire staff, and, in some cases, seek accreditation. But for some businesses — especially those that stand to lose tens of thousands of dollars from production pauses when staff need to send a critical device away for adjustment — there is an obvious business case for calibrating in-house.
For the right business, on-site calibration can be a huge time- and money-saver in the long run. When you calibrate measurement instruements in your own facility, you can:
- Skip long wait times that often come with sending instruments away for calibration
- Calibrate large volumes of instruments or assets, which is especially helpful for large facilities
- Improve access to calibration for staff working in remote and rural areas
- Make your own custom ranges or set points for quick calibration on specialized assets
- Avoid miscommunication with third-party labs about your custom calibration needs
- Minimize production disruptions and keep equipment up and running longer
- Calibrate critical assets on site, without removing them from the production line
Since calibration is necessary in almost every industry, it’s impossible to give a one-size-fits-all recommendation on which businesses should start their own calibration labs. You’ll have to run a cost-benefit analysis (see step 3 below) and determine your specific calibration needs to figure out if it’s worth it for your organization.
However, Fluke Calibration specialists have observed some trends among companies that benefit from in-house calibration. Many are large operations that need to calibrate hundreds or thousands of assets, and sending these to a third-party lab would be cumbersome and expensive. Others are organizations that rely on a few critical assets for operation and can’t afford any downtime, so they need calibration solutions on-hand to perform adjustments or verifications directly onsite.
Regardless of your situation, you’ll need to thoroughly examine your facility’s needs and capacity to determine which calibration solutions are best for your team.
10 Steps to Starting a Calibration Lab
Since no two operations are the same, no two in-house calibration labs are the same, either. If you’re planning your own facility, you’ll have to determine what types of calibration you need to conduct, how much it will cost, and lay out standard operating procedures (SOPs), among other steps.
This can be a long process, but the payoff is enormous for the right operations. Here are the 10 most important steps you’ll need to follow to build your lab from the ground up.
1. Define Your Scope
First, determine the types of calibration you want to conduct in your lab. Keep in mind that you won’t need to calibrate every piece of equipment on site. You can focus your lab exclusively on critical assets or equipment with specialized ranges and send the rest to a third-party lab if it’s more cost-effective.
The assets you’ll want to calibrate in-house are typically:
- Critical to operations
- Frequently in use (and therefore require more frequent calibrations)
- Cumbersome or expensive to ship
- Used in large numbers in the facility
- Located in a remote area
As you define the scope of your lab, make a list of all the assets you plan to calibrate. Note the quantities of each asset, their locations, and what kinds of calibration equipment you already have to get the job done. If you don’t know what you’ll need to calibrate a certain asset, skip to step two.
2. Research Calibration Processes
Calibration can be complex or simple, depending on the assets you work with. For example, you cancheaply calibrate a pressure gauge with just a reference and a hand pump, provided the environmental conditions and measurement uncertainty are controlled. But if you’re calibrating attenuators, which are common in telecommunications systems, you’ll need to hire a skilled technician who can operate a vector network analyzer that costs thousands of dollars.
Additionally, technicians must carry out many calibrations in carefully controlled settings. Factors like humidity, temperature, and external vibration can disrupt calibrations and cause inaccurate results. As you learn about calibration practices, pay attention to any environmental conditions that might apply to your specific situation.
To find information about procedures and uncertainty specifications, reference OEM manuals. Fluke Calibration also has a range of guides about calibrating common equipment, as do organizations like NCSLI, ASTM, and NIST, if you’re looking for standard calibration procedures. For laboratory implementation, ISO/IEC 17025 is also the key international standard to consider.
3. Run a Cost-Benefit Analysis
Before breaking ground on a new lab, conduct a cost-benefit analysis to see if it’s worth the investment. Once you know the amounts and types of assets you want to calibrate, create a rough estimate of your calibration equipment costs. Also factor in accessories you may need like adapters, heaters, or storage carts.
| Example cost-benefit calculation | Estimate |
|---|---|
| Digital multimeters calibrated externally | 100 units |
| Cost per external calibration | $250 per unit |
| Estimated annual calibration spend | $25,000 |
| Approximate cost of in-house standard | $75,000 |
| Estimated payback period | 3 years |
Consider, too, if you need to hire specialists to conduct calibration tasks. Are you planning to test and adjust complex spectrum analyzers or simple pressure gauges? The need for metrologists or other technical staff may add significant costs to your budget. Remember to include not only initial investments but also ongoing operational costs such as maintenance of reference standards, periodic recalibration, training, and reaccreditation cycles.
Finally, determine any needs for the physical space where you will conduct calibrations. Will the lab space require any specific upgrades, such as the ability to control temperature or vibration levels? This depends on your industry and the types of calibration you want to conduct. In some cases, you may also want to seek accreditation after the lab is built, which can add to the cost.
Once you have a rough estimate of the price for your new lab, compare it to what your team currently spends on calibration per year and determine if the cost of construction and setup makes financial sense over time. You want to reach a breakeven point where calibration costs will dip over the coming years once you’ve paid off the initial construction bill.
Again, it’s important to remember that you’re playing the long game when investing in calibration. Upfront costs may look high, and you likely won’t see an immediate payoff. But if you plan it right, your ROI will make it worth the effort.
4. Choose the Right Location
Whether you’re retrofitting an existing facility, constructing a new one, or building a mobile calibration lab, your environment will need to carefully control for any outside factors that may interfere with testing and measurement. These include:
- Humidity
- Temperature
- Vibration
- Air pressure/altitude
- Power quality
- Dust and debris
For example, if you’re calibrating machine vibration sensors in a building next to a loading dock, your instrument under test (UUT) will likely pick up vibrations from nearby trucks. You won’t get an accurate picture of the vibration sensor’s performance with this kind of interference. To avoid it, you’ll have to insulate the laboratory or move it to a different location.
Some calibration labs need to adjust for Earth-level factors like magnetism and gravity, depending on the type of devices they measure. If you plan to break ground on a new facility, reach out to an organization like the United States Geological Survey (USGS) or regional equivalent to assess the land you’ll build your laboratory on. You may have to construct a separate foundation for your facility to control for any fluctuations in grounding conditions.
For more in-depth information, the International Organization of Legal Metrology (OIML) has guides that can help with building a new laboratory, like OIML G 13:1989, Layout of a Calibration Laboratory. Additionally, ISO/IEC 17025 provides requirements for facilities and environmental conditions that are widely recognized by accreditation bodies.
5. Purchase Equipment and Accessories
After researching calibration processes in step two, you should have an idea of the type of equipment your team needs to buy for the lab. Typical devices include reference standards, multifunction calibrators, wells, and multimeters.
Also consider how you will use this equipment. Will you measure assets in the laboratory, or bring equipment to the assets to measure on the floor?
Keep in mind that calibration equipment doesn’t always need to be stationary in the lab — you can build an equipment cart with the necessary tools to calibrate assets right on the production line. This is especially helpful for critical machines that cannot easily be removed or transported to a lab for calibration.
Fluke Calibration carries a wide range of trusted calibration tools and accessories. Visit our calibration solutions homepage to learn more.
6. Hire Staff
At this step, assess your staffing needs and hire new personnel if necessary. This will depend on the size, workload, and complexity of your laboratory.
At minimum, you will need staff technicians to manage your calibration laboratory and run tests. Most in-house calibration laboratories with simple procedures can operate without a staff metrologist. However, if you’re conducting specialized calibrations or plan to seek accreditation, you will likely need a qualified metrologist to oversee technical competence and ensure compliance with standards such as ISO/IEC 17025.
7. Create Procedures
Once your staff is on board, it’s time to create the laboratory’s standard operating procedures (SOPs). This is the guidebook for all calibration rules and processes in your laboratory.
Designate a lab employee to oversee the documentation and storage of all procedures; typically, a process engineer or lab manager is a good fit for this role. Then, check if there are standard procedures already written for the tools your lab plans to calibrate. (In all likelihood, you’ll have gathered some research on this matter as a result of step two.) From there, you can make any adjustments for custom calibration ranges or equipment descriptions to fit with the lab setup.
Then, build workflow procedures around your calibration processes to ensure that every asset is properly documented as it moves through the lab. It’s important to track calibration data for audits, customer calibration records, and future accreditation.
8. Run Tests
Before opening your lab and accepting calibration orders, have lab staff test the new SOPs to make sure everything runs smoothly. Keep a record of any process inefficiencies that you may need to improve later. If there are any steps that seem to negatively impact calibration accuracy, mark these as high-priority and fix them before the official launch date of the lab.
Make sure to brief staff members on all operating protocols so that there is uniformity in how they perform calibrations. If possible, check your new lab’s results against a third-party lab’s assessment of the same equipment. This will help you ensure calibration accuracy and demonstrate measurement traceability before you take on a much larger workload.
9. Assess Accreditation Needs
In-house calibration laboratories don’t typically need accreditation to operate. However, in some cases, it may be in your best interest to seek third-party accreditation.
For example, accreditation can reduce the need for supplier audits. If you are accredited, you can confidently tell customers that you have already been evaluated by a third party for compliance. This is especially helpful in industries like pharmaceutical and food and beverage manufacturing, which have tight regulations.
You’ll have to research your specific industry needs for lab accreditation, but the most widely recognized standard is ISO/IEC 17025, which accreditation bodies worldwide use to assess the competence of testing and calibration laboratories. (NIST has a helpful guide about accreditation on their website.) Also keep in mind that accreditation is a lengthy process, and it may take several tries to receive your certificate. Make sure to plan ahead if this is an important step for your calibration lab.
10. Launch Your Lab
Once you’ve finalized SOPs, trained staff, and tested your equipment, it’s time to officially open the doors to your new lab.
Make sure that all relevant parties throughout your organization are aware of the calibration services you offer. A company-wide email or newsletter could help you get the word out.
Also consider how your lab will accept calibration requests. Will clients submit work requests through an online platform like MET/CAL, or simply bring their equipment to the laboratory when they need assistance? Design a system that gives your teams a clear overview of work requests, status updates, and priority needs.
Remember that you may need to update and improve your systems as time goes on. As your organization grows, there may also be opportunities to add to your current calibration capabilities or workload. Building a lab that can scale to your organization’s needs will ensure its value for years to come.
Choosing the Best Calibration Solution for Your Workflow
An in-house calibration lab is a worthwhile investment for many businesses. It makes calibration quicker, more customized, and can cut down calibration spend in the long run. But in order for it to be a cost-saving measure for your business, it’s important to assess your calibration needs and do a cost-benefit analysis to make sure it’s the best option for your organization.
Some companies will ultimately spend more on calibration by buying all their own equipment and staffing the right technicians instead of hiring a third-party lab. The decision to do so, despite the costs, all depends on the types of calibration you plan to conduct, how frequently you’ll calibrate in-house, and how critical the assets are that you plan to calibrate.
Ultimately, you’ll want to choose the best calibration option for your team financially and logistically. Fluke Calibration offers a range of tools and equipment for every organization, whether you decide to build your own laboratory or work with our service center to calibrate off-site. Visit our calibration solutions page for more information.