New features in recent MET/CAL software versions
New in the latest release MET/CAL (v10.2) improvements:
- New FSC for Fluke 5322A lets you fully automate calibration of the Electrical Safety Calibrator
- New FSC for Fluke 8558A to automate the 8.5-digit Multimeter calibration
- New FSC for Fluke 4180 and Fluke 4181 for automated calibration of IR thermometers
- Enhanced results saving and improved error logging for failures
- Easy collection of log files with a single click to provide to technical support for assistance without needing to comb through multiple separate files
- Upgraded Procedure Editor for better usability and more choices for procedure writers
- Upgraded instrument configuration screen for better usability, a more modern user interface and better control when moving and resizing windows
- More meaningful and useful error messages
MET/TEAM (v3.0) improvements:
- Significant speed improvements
- Increased flexibility in Manual Templates
- Improved Data Check editor makes it easier to set up customized data checks and access more of MET/TEAM with them
- MET/TEAM API to interface with other applications, making it easier and safer to transfer data between applications
- Dynamic calculation of manual template limits; when you change a set point tolerances are calculated automatically, providing better flexibility
What are you missing? Having the latest version of MET/CAL software gives you access to many new features and functions. Here are just a few examples of the additional capabilities added with each new update.
New features in recent MET/CAL software versions
| Features | 9.0 | 9.1 | 9.2 | 10.0/10.1 | 10.2 |
| New Runtime user interface | |||||
| • | • | • | • | • | |
| User-group-based security | |||||
| • | • | • | • | • | |
| Test results data export | |||||
| • | • | • | • | • | |
| Windows 10 compatibility | |||||
| • | • | • | • | • | |
| Settings stored directly in database | |||||
| • | • | • | • | ||
| One workstation supporting multiple configurations | |||||
| • | • | • | • | ||
| Automatic migration of legacy formatted procedures (PROC.DIR) to projects and PXEs | |||||
| • | • | • | • | ||
| New procedure directory scheme for improved security and version control | |||||
| • | • | • | • | ||
| Language support for MET/CAL - German, Russian, French, Spanish, Portuguese, Chinese, Italian, and Japanese | |||||
| • | • | • | • | ||
| Global Unique Identifiers allowing access to SQL server replication | |||||
| • | • | • | • | ||
| FSC Support for the Rohde & Schwarz NRPT sensor series for the Fluke Calibration 96270A | |||||
| • | • | • | |||
| Enhanced results save process to MET/TEAM with improved logging | |||||
| • | • | • | |||
| Support for MET/CONNECT as an alternative backend to MET/TEAM | |||||
| • | • | ||||
| FSC Support for the Fluke 5790B and Fluke 8588A | |||||
| • | • | ||||
| Additional logging and data saving improvements with both MET/TEAM and MET/CONNECT | |||||
| • | • | ||||
| FSC Support for the Fluke 5322A, Fluke 8558A, Fluke 4180, and Fluke 4181 | |||||
| • | |||||
| Modernized Instrument Configuration Dialogs | |||||
| • | |||||
| More robust automatic reconnection to MET/TEAM after a lost connection | |||||
| • | |||||