Fluke 805 Vibration Meter
Model#: Fluke 805Part#: 4094385UPC#: 0 95969 61069 8
Compare products: vibration analysis
Key features
- Reliable, repeatable, accurate device for checking bearings and overall vibration
 - Features innovative sensor design that minimizes measurement variations caused by device angle or contact pressure
 - Provides consistent data quality at both low and high frequency ranges
 - Offers four-level severity scale to assess urgency of problems and bearing condition
 
Sale ends soon.
Shop now!
DAYS
HR
MIN
SEC
$2,977.51
Product overview: Fluke 805 Vibration Meter
The Reliable, Repeatable, Accurate Way to Check Bearings and Overall Vibration
Make go or no-go maintenance decisions with confidence. The Fluke 805 Vibration Meter is the most reliable vibration screening device available for frontline mechanical troubleshooting teams that need repeatable, severity-scaled readings of overall vibration and bearing condition.
What Makes the 805 the Best Choice?
- A meter – not a pen – that measures overall vibration as well as specific variables like bearing condition and temperature, to provide a more complete picture
 - A combination vibration and force sensor tip that compensates for user variance (force or angle) yielding accurate, repeatable readings
 - A four-level severity scale and onboard processor calculate bearing condition and overall vibration using easy-to-understand textual alerts (Good, Satisfactory, Unsatisfactory, Unacceptable)
 - Sensor sensitivity can read a wide range of frequencies (10 to 1,000 Hz and 4,000 to 20,000 Hz) covering most machine and component types
 - Straight-forward user interface that minimizes the user inputs to RPM range and equipment type
 
Other useful features:
- Measures overall vibration (10 Hz to 1,000 Hz) for acceleration, velocity, and displacement units of measurement for a wide variety of machines
 - Provides Crest Factor+ technology for reliable bearing assessment using direct sensor tip measurements between 4,000 Hz and 20,000 Hz
 - Compares vibration levels with ISO-10816 severity scales
 - Allows you to view trending in Microsoft® Excel using pre-built templates
 - Features colored lighting system (green, red) and on-screen comments to indicate how much pressure needs to be applied to take measurements
 - Measures temperature with Spot IR Sensor to increase diagnostic capabilities
 - Holds and saves up to 3,500 measurements in on-board memory
 - Provides external accelerometer support for hard to reach locations
 - Allows you to export data via USB
 - Provides audio output for listening to bearing tones directly
 - Features built-in flashlight for viewing measurement locations in dark areas
 - Provides large high-resolution display for easy navigation and viewing
 
Specifications: Fluke 805 Vibration Meter
| Vibration Meter | ||
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz | |
| High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz | |
| Severity levels | Good, satisfactory, unsatisfactory, unacceptable | |
| Vibration limit | 50 g peak (100 g peak-peak) | |
| A/D converter | 16-bit | |
| Signal to noise ratio | 80 dB | |
| Sampling rate | Low frequency | 20,000 Hz | 
| High frequency | 80,000 Hz | |
| Real time clock backup | Coin battery | |
| Sensor | ||
| Sensitivity | 100 mV g ±10% | |
| Measurement range | 0.01 g to 50 g | |
| Low frequency range (overall measurement) | 10 Hz to 1,000 Hz | |
| High frequency range | 4,000 Hz to 20,000 Hz | |
| Resolution | 0.01 g | |
| Accuracy | At 100 Hz ±5% of measured value | |
| Amplitude Units | ||
| Acceleration | g, m/sec² | |
| Velocity | in/sec, mm/sec | |
| Displacement | mils, mm | |
| Infrared Thermometer (Temperature Measurement) | ||
| Range | -20°C to 200°C (-4°F to 392°F) | |
| Accuracy | ±2°C (4°F) | |
| Focal length | Fixed, at ~3.8 cm (1.5 in) | |
| External sensor | ||
| Fluke supports but does not provide external sensors | ||
| Frequency range | 10 Hz to 1,000 Hz | |
| Bias voltage (to supply power) | 20 VDC to 22 VDC | |
| Bias current (to supply power) | Maximum 5 mA | |
| Firmware | ||
| External interfaces | USB 2.0 (full speed) communication | |
| Data capacity | Database on internal flash memory | |
| Upgrade | Through USB | |
| Memory | Up to 3,500 measurements | |
| Radiated Emission | ||
| Electrostatic discharge: burst | Standard EN 61000-4-2 | |
| Electromagnetic interference | Standard EN 61000-4-3 | |
| RE | Standard CISPR 11, Class A | |
| Environmental | ||
| Operating temperature | -20°C to 50°C (-4°F to 122°F) | |
| Storage temperature | -30°C to 80°C (-22°F to 176°F) | |
| Operating humidity | 10% to 95% RH (non-condensing) | |
| Operating/storage altitude | Sea level to 3,048 meters (10,000 feet) | |
| IP rating | IP54 | |
| Vibration limit | 500 g peak | |
| Drop test | 1 meter | |
| General Specifications | ||
| Battery type | AA (2) Lithium Iron Disulfide | |
| Battery life | 250 measurements | |
| Size (L x W x H) | 24.1 x 7.1 x 5.8 cm (9.5 x 2.8 x 2.3 in) | |
| Weight | 0.40 kg (0.89 lb) | |
| Connectors | USB mini-B 7-pin, stereo audio output jack (3.5 mm Audio Plug), external sensor jack (SMB connector) | |
Models: Fluke 805 Vibration Meter
Fluke 805
Fluke 805 Vibration Meter
Part#: 4094385UPC#: 0 95969 61069 8
Includes:
- USB cable
 - Storage case
 - Belt holster
 - Quick reference guide
 - CD-ROM (includes MS Excel template and documentation)
 - Two (2) AA batteries
 
Manuals + resources: Fluke 805 Vibration Meter
- 3 Ways To Improve Motor Health With Vibration Testing
 - 7 money-saving tools for your team
 - Machine wear: how vibration analysis has evolved to increase uptime
 - Reporting provides the quick answers you need
 - They are better together— Ti400 Infrared Camera and Fluke 805 FC Vibration Meter
 - Tiered maintenance uses new smart tools and work practices to boost reduced resources
 - Top 5 questions all technicians should ask for more machine uptime
 - What You Need To Know About Vibration Tools
 
- Connecting a thermal imager to your iPhone
 - Connecting multiple tools at the same time with Fluke Connect®
 - Connecting the T3000 FC with the Fluke Connect™ app
 - How to create an equipment baseline with EquipmentLog™ history
 - How to email a measurement using the Fluke Connect app
 - How to Measure with Vibration Meters
 - How to record measurements and graphs
 - How to save measurements to EquipmentLog™ history
 - How to Set-Up Vibration Meters
 - How to share measurements on equipment using the Fluke Connect™ app
 - Identifying intermittent conditions with TrendIt™ graphs
 - Introduction to 789 FC
 - Measurement history in one place using EquipmentLog™ history
 - Measuring from a safe distance using the Fluke Connect™ app
 - Performing predictive maintenance with Fluke Connect™
 - Saving measurements with AutoRecord™ measurements
 - Share equipment health with EquipmentLog™ history
 - Using ShareLive™ video call to share live measurements and video
 - Viewing and graphing three phase measurements
 - What are the Differences Between the Fluke 805 and Fluke 810
 - What is Fluke Connect®
 