Fluke Calibration 1502A/1504 Thermometer Readout
Model#: Fluke 1502APart#: 1648927UPC#: 0 95969 12019 7
Key features
- 1502A: accuracy up to ±0.006 °C.
 - 1504: accuracy up to ±0.002 °C plus ability to measure thermistor temperature sensors.
 - 1502A: covers –200°C to 962°C
 - 1504: covers 0 to 100°C
 - Can take readings up to twice per second, making the calibration process faster.
 
Sale ends soon.
Shop now!
DAYS
HR
MIN
SEC
$3,975.00
Product overview: Fluke Calibration 1502A/1504 Thermometer Readout
Precision thermometer readouts for laboratory and field use
1502A Tweener PRT Readout
The Fluke Calibration 1502A Tweener offers precision temperature measurement with:
- Accuracy up to ±0.006 °C
 - Resolution of 0.001 °C across the entire range
 - Compatibility with 100-ohm, 25-ohm, and 10-ohm RTD probes
 - Smallest unit in its class, ideal for field or bench use
 
Advanced Features
- Programmable to match a probe’s constants for maximum linearity and accuracy
 - Displays temperature in °C, °F, K, or resistance in ohms
 - Reads standard industrial IEC-751 / “385 ALPHA” RTDs with no programming required
 - Accepts ITS-90 subranges 4 and 6–11, with formulas built into firmware
 - Calibration is done digitally via front-panel—no need to open the device
 - Comes with RS-232 interface; optional IEEE-488 interface available
 
1504 Tweener Thermistor Readout
Need higher precision in a narrower temperature range? The Model 1504 Tweener offers:
- Accuracy up to ±0.002 °C
 - Resolution of 0.0001 °C
 - Designed specifically for thermistors—more robust, shock-resistant sensors with faster response times
 - Ideal for applications requiring high sensitivity and reliability in limited temperature spans
 
Software Compatibility
Enhance your workflow with Fluke software tools:
- 9934 LogWare: Real-time data acquisition, graphing, and analysis
 - MET/TEMP II: Use Tweeners as reference thermometers for automated calibrations
 
Specifications: Fluke Calibration 1502A/1504 Thermometer Readout
| Specifications | 1502A | 1504 | 
| Temperature Range† | −200 °C to 962 °C (−328 °F to 1764 °F) | Any thermistor range | 
| Resistance Range | 0 Ω to 400 Ω, auto-ranging | 0 Ω to 1 MΩ, auto-ranging | 
| Probe | Nominal RTPW: 10 Ω to 100 Ω RTD, PRT, or SPRT  | Thermistors | 
| Characterizations | ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11 IPTS-68: R0, a, d, a4, and c4 Callendar-Van Dusen: R0, a, d, and b  | Steinhart-Hart thermistor polynomial Callendar-Van Dusen: R0, a, d, and b  | 
| Resistance Accuracy (ppm of reading)  | 0 Ω to 20 Ω: 0.0005 Ω 20 Ω to 400 Ω: 25 ppm  | 0 Ω to 5 KΩ: 0.5 Ω 5 KΩ to 200 KΩ: 100 ppm 200 KΩ to 1 MΩ: 300 ppm  | 
| Temperature Accuracy† | ±0.004 °C at −100 °C ±0.006 °C at 0 °C ±0.009 °C at 100 °C ±0.012 °C at 200 °C ±0.018 °C at 400 °C ±0.024 °C at 600 °C  | ±0.002 °C at 0 °C ±0.002 °C at 25 °C ±0.004 °C at 50 °C ±0.010 °C at 75 °C ±0.020 °C at 100 °C (Using 10 KΩ thermistor sensor, a=0.04. Does not include probe uncertainty or characterization errors.)  | 
| Operating Temperature Range | 16 °C to 30 °C | 13 °C to 33 °C | 
| Resistance Resolution | 0 Ω to 20 Ω: 0.0001 Ω 20 Ω to 400 Ω: 0.001 Ω  | 0 Ω to 10 KΩ: 0.01 Ω 10 KΩ to 100 KΩ: 0.1 Ω 100 KΩ to 1 MΩ: 1 Ω  | 
| Temperature Resolution | 0.001 °C | 0.0001 °C | 
| Excitation Current | 0.5 and 1 mA, user selectable, 2 Hz | 2 and 10 µA, automatically selected | 
| Measurement Period | 1 second | |
| Digital Filter | Exponential, 0 to 60 seconds time constant (user selectable) | |
| Probe Connection | 4-wire with shield, 5-pin DIN connector | |
| Communications | RS-232 serial standard IEEE-488 (GPIB) optional  | |
| Display | 8-digit, 7-segment, yellow-green LED; 0.5-inch-high characters | |
| Power | 115 VAC (±10 %), 50/60 Hz, 1 A, nominal 230 VAC (±10 %), 50/60 Hz, 1 A, nominal, specify  | |
| Size (HxWxD) | 61 x 143 x 181mm (2.4 x 5.6 x 7.1 in) | |
| Weight | 1.0 kg (2.2 lb.) | |
| Calibration | ISO 17025-accredited calibration provided | |
| †Temperature ranges and accuracy may be limited by the sensor you use. | ||
Models: Fluke Calibration 1502A/1504 Thermometer Readout
Fluke 1502A
Fluke Calibration 1502A-156 Thermometer Readout
−200°C to 962°C (−328°F to 1764°F)
Part#: 1648927−200°C to 962°C (−328°F to 1764°F)
UPC#: 0 95969 12019 7
1502A-2506
Tweener PRT Readout, with IEEE-488
Fluke 1504
Fluke Calibration 1504 Thermometer Readouts
Any thermistor range
Part#: 1648966Any thermistor range
UPC#: 0 95969 12023 4
1504-2506
Tweener Thermistor Readout, with IEEE-488
9934-M
LogWare, Single Channel, Multi User
Part#: 1658732Manuals + resources: Fluke Calibration 1502A/1504 Thermometer Readout
- Calculating Calibration Uncertainties in an Automated Temperature Calibration System
 - Establishment of a Secondary Temperature Calibration Laboratory
 - Industrial temperature readout and probe selection guide
 - Probe-to-Readout Adapter Guide
 - PRT Temperature vs. Resistance Table
 - Temperature Calibration Equipment: A Technician's Guide
 - Temperature measurement and calibration: What every instrument technician should know
 