Fluke 117 and 323 Electrician’s Multimeter Combo Kit

  • Fluke 117 and 323 Electrician’s Multimeter Combo Kit

Najważniejsze cechy

Fluke117 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • VoltAlert™ technology for non-contact voltage detection.
  • AutoVolt automatic ac/dc voltage selection.
  • Low input impedance: Helps prevent false readings due to ghost voltage.
  • Large white LED backlight to work in poorly lit areas.
  • True-rms for accurate measurements on non-linear loads.
  • Measures 10 A (20 A overload for 30-seconds).
  • Resistance, continuity, frequency and capacitance.
  • Min/Max/Average to record signal fluctuations.
  • Compact ergonomic design for one-handed operation.
  • CAT III 600 V safety rated.

Fluke 323 True-rms Clamp Meter.Rugged. Reliable. Precise.

  • 400 A ac current measurement.
  • 600 V ac and dc voltage measurement.
  • True-rms ac voltage and current for accurate measurements on non-linear signals.
  • Resistance measurement up to 40 k? with continuity detection.
  • Slim, ergonomic design.
  • CAT IV 300V/CAT III 600 V safety rating.

Omówienie produktu: Fluke 117 and 323 Electrician’s Multimeter Combo Kit

This combo kit pairs the Fluke 117 DMM with a Fluke 323 clamp meter for productive and effective troubleshooting in one total solution, including the C115 durable soft carrying case for protection and easy meter transportation.

Specyfikacje: Fluke 117 and 323 Electrician’s Multimeter Combo Kit

Fluke 117 Digital Multimeter

Specifications
Maximum voltage between any terminal and earth ground600 V
Surge protection6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery life400 hours typical, without backlight
Accuracy Specifications
DC millivoltsRange/Resolution600.0 mV / 0.1 mV
Accuracy±([% of reading] + [counts]): 0.5% + 2
DC voltsRange/Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.00 V / 0.1 V
Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto voltsRange/Resolution600.0 V / 0.1 V
Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz)
4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMSRange/Resolution600.0 mV / 0.1 mV
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMSRange/Resolution6.000 V / 0.001 V
60.00 V / 0.01 V
600.0 V / 0.1 V
Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz)
2.0% + 3 (500 Hz to 1 kHz)
ContinuityRange/Resolution600 Ω / 1 Ω
AccuracyBeeper on < 20 Ω, off > 250 Ω; detects opens or shorts of
500 μs or longer.
OhmsRange/Resolution600.0 Ω / 0.1 Ω
6.000 kΩ / 0.001 kΩ
60.00 kΩ / 0.01 kΩ
600.0 kΩ / 0.1 kΩ
6.000 MΩ / 0.001 MΩ
Accuracy0.9% + 1
Range/Resolution40.00 MΩ / 0.01 MΩ
Accuracy5% + 2
Diode testRange/Resolution2.00 V / 0.001 V
Accuracy0.9% + 2
CapacitanceRange/Resolution1000 nF / 1 nF
10.00 μF / 0.01 μF
100.0 μF / 0.1 μF
9999 μF / 1 μF
100 μF to 1000 μF
Accuracy1.9% + 2
Range/Resolution> 1000 μF
Accuracy5% + 20%
Lo-Z capacitanceRange1 nF to 500 μF
Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz)Range/Resolution6.000 A / 0.1 A
10.00 A / 0.01 A
Accuracy1.5% + 3
20 A continuous overload for 30 seconds max
DC ampsRange/Resolution6.000 A / 0.1 A10.00 A / 0.01 A
Accuracy1.0% + 3
20 A continuous overload for 30 seconds max
Hz (V or A input)²Range/Resolution99.99 Hz / 0.01 Hz
999.99 Hz / 0.1 Hz
9.999 Hz / 0.001 Hz
50.00 Hz / 0.01 Hz
Accuracy0.1% + 2
1. All AC voltage ranges except Auto-V/LoZ are specified from 1% to 100% of range. Auto-V/LoZ is specified from 0.0 V.
2. Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
• Frequency is AC coupled, 5 Hz to 50 kHz for AC voltage. Frequency is DC coupled, 45 Hz to 5 kHz for AC current.
• Temperature Range/Resolution: -40°F to 752°F / 0.2°F.
Mechanical and General Specifications
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years
 

Fluke 323 True RMS Clamp Meter

Specifications
AC currentRange400.0 A
Accuracy2% ±5 digits
(45 Hz to 65 Hz)
2.5% ±5 digits
(65 Hz to 400 Hz)
AC voltageRange600.0 V
Accuracy1.5% ±5 digits
DC voltageRange600.0 V
Accuracy1.0% ±5 digits
ResistanceRange/Resolution400.0 Ω/ 4000 Ω
Accuracy1.0% ±5 digits
Continuity≤ 70 Ω
AC responseTrue RMS
Data holdYes
SizeH x W x D (mm)207 x 75 x 34
Max wire diameter30 mm (600 MCM)
Weight265 g
Category ratingCAT III 600 V
CAT IV 300 V
WarrantyTwo-year

Modele: Fluke 117 and 323 Electrician’s Multimeter Combo Kit

Fluke 117/323 Kit
Fluke 117/323 Electricians Multimeter Combo Kit

Kup

Includes:

  • Fluke 117 Digital Multimeter
  • Fluke 323 True RMS Clamp Meter