Fluke Calibration 9143 Field Metrology Well
Belangrijkste kenmerken
- Lightweight, portable, and fast
- Built-in two-channel readout for PRT, RTD, thermocouple, 4-20 mA current
- True reference thermometry with accuracy to ยฑ0.01 ยฐC
- On-board automation and documentation
- Metrology performance in accuracy, stability, uniformity, and loading
ย
Productoverzicht: Fluke Calibration 9143 Field Metrology Well
Built-in features to address large workloads and common applications
Whether you need to calibrate 4-20 mA transmitters or a simple thermostatic switch, a Field Metrology Well is the right tool for the job. With three models covering the range of โ25 ยฐC to 660 ยฐC, this family of Metrology Wells calibrates a wide range of sensor types. The optional process version (models 914X-X-P) provides a built-in two-channel thermometer readout that measures PRTs, RTDs, thermocouples, and 4-20 mA transmitters which includes the 24 V loop supply to power the transmitter.
Each process version accepts an ITS-90 reference PRT. The built-in readout accuracy ranges from ยฑ0.01 ยฐC to ยฑ0.07 ยฐC depending on the measured temperature. Reference PRTs for Field Metrology Wells contain individual calibration constants that reside in a memory chip located inside the sensor housing, so sensors may be used interchangeably. The second channel is user-selectable for 2-, 3-, or 4-wire RTDs, thermocouples, or 4-20 mA transmitters. For comparison calibration, donโt hassle with carrying multiple instruments to the field. Field Metrology Wells do it all as a single instrument.
Traditionally, calibrations of temperature transmitters have been performed on the measurement electronics, while the sensor remained uncalibrated. Studies have shown, however, that typically 75% of the error in the transmitter system (transmitter electronics and temperature sensor) is in the sensing element. Thus, it becomes important to calibrate the whole loopโboth electronics and sensor.
The process option of Field Metrology Wells makes transmitter loop calibrations easy. The transmitter sensor is placed in the well with the reference PRT and the transmitter electronics are connected to the front panel of the instrument. With 24 V loop power, you are able to power and measure the transmitter current while sourcing and measuring temperature in the Field Metrology Well. This allows for the measurement of as-found and as-left data in one self-contained calibration tool.
All Field Metrology Wells allow for two types of automated thermostatic switch test proceduresโauto or manual setup. Auto setup requires the entry of only the nominal switch temperature. With this entry, it will run a 3-cycle calibration procedure and provide final results for the dead band temperature via the display. If you need to customize the ramp rate or run additional cycles, the manual setup allows you to program and run the procedure exactly how you would like. Both methods are fast and easy and make testing temperature switches a virtual joy!
Metrology performance for high-accuracy measurements
Unlike traditional dry-wells, Field Metrology Wells maximize speed and portability without compromising the six key metrology performance criteria laid out by the EA: accuracy, stability, axial (vertical) uniformity, radial (well-to-well) uniformity, loading, and hysteresis. All criteria are important in ensuring accurate measurements in all calibration applications. Field Metrology Well displays are calibrated with high quality traceable and accredited PRTs. Each device (process and non-process versions) comes with an IEC-17025 accredited calibration certificate, which is backed by a robust uncertainty analysis that considers temperature gradients, loading effects, and hysteresis. The 9142 and 9143 have a display accuracy of ยฑ0.2 ยฐC over their full range, and the 9144 display accuracy ranges from ยฑ0.35 ยฐC at 420 ยฐC to ยฑ0.5 ยฐC at ยฑ660 ยฐC. Each calibration is backed with a 4:1 test uncertainty ratio.
New control technology guarantees excellent performance in extreme environmental conditions. The 9142 is stable to ยฑ0.01 ยฐC over its full range and the mid-range 9143 is stable from ยฑ0.02 ยฐC at 33 ยฐC and ยฑ0.03 ยฐC at 350 ยฐC. Even at 660 ยฐC, the 9144 is stable to ยฑ0.05 ยฐC. But this is not all! Thermal block characteristics provide radial (well-towell) uniformity performance to ยฑ0.01 ยฐC. Dual-zone control helps these tools achieve axial uniformity to ยฑ0.05 ยฐC at 40 mm (1.6 in).
Automation and documentation make each unit a turnkey solution
So you now have a precision calibration instrument that has field-ready characteristics, accredited metrology performance, built-in two-channel thermometry, and automationโ what else could you ask for? How about all this and a turnkey solution that will automate and document the results?
The process versions of Field Metrology Wells have onboard non-volatile memory for documentation of up to 20 tests. Each test can be given a unique alphanumeric ID and will record block temperature, reference temperature, UUT values, error, date, and time. Each test can be easily viewed via the front panel. Use the 1586A Super-DAQ to automate temperature sensor calibration with these Field Metrology Wells.
Operation is as easy as 1-2-3
Youโll find Field Metrology Wells intuitive and easy to use. Each unit is equipped with a large, easy-to-read LCD display, function keys, and menu navigation buttons. Its โSET PT.โ button makes it straightforward and simple to set the block temperature. Each product has a stability indicator that visually and audibly tells you the Field Metrology Wells is stable to the selectable criteria. Each unit offers preprogrammed calibration routines stored in memory for easy recall, and all inputs are easily accessible via the front panel of the instrument. Never buy a temperature calibration tool from a company that only dabbles in metrology (or doesnโt even know the word). Metrology Wells from Fluke are designed and manufactured by the same people who equip the calibration laboratories of the worldโs leading temperature scientists. These are the people around the world who decide what a Kelvin is! We know a thing or two more about temperature calibration than the vast majority of the worldโs dry-well suppliers. Yes, they can connect a piece of metal to a heater and a control sensor. But we invite you to compare all our specs against the few that they publish. (And by the way, we meet our specs!).
Small dry wells for big field applications
The 9142, 9143, 9144 Field Metrology Wells extend high performance to the industrial process environment by maximizing portability, speed, and functionality with little compromise to metrology performance.
Field Metrology Wells are packed with functionality and are remarkably easy to use. They are lightweight, small, and quick to reach temperature set points, yet they are stable, uniform, and accurate. These industrial temperature loop calibrators are perfect for performing transmitter loop calibrations, comparison calibrations, or simple checks of thermocouple sensors. With the โprocessโ option, there is no need to carry additional tools into the field. This optional built-in two-channel readout reads resistance, voltage, and 4โ20 mA current with 24 volt loop power. It also has on-board automation and documentation. Combined, the three models (9142, 9143, and 9144โeach with a โprocessโ option) cover the wide range of โ25 ยฐC to 660 ยฐC.
High performance for the industrial environment
Field Metrology Wells are designed for the industrial process environment and fast speed to temperature. They weigh less than 8.2 kg (18 lb) and have a small footprint, which makes them easy to transport.
Field environment conditions are typically unstable, having wide temperature variations. Each Field Metrology Well has a built-in gradient-temperature compensation (patent pending) that adjusts control characteristics to ensure stable performance in unstable environments. In fact, all specifications are guaranteed over the environmental range of 13 ยฐC to 33 ยฐC.
ย
Specificaties: Fluke Calibration 9143 Field Metrology Well
| Base Unit Specifications | |
| Temperature range at 23ยฐC | 33ยฐC to 350ยฐC (91ยฐF to 662ยฐF) |
| Display accuracy | ยฑ0.2ยฐC Full Range |
| Stability | ยฑ0.02ยฐC at 33ยฐC ยฑ0.02ยฐC at 200ยฐC ยฑ0.03ยฐC at 350ยฐC |
| Axial uniformity at 40 mm (1.6 in) | ยฑ0.04ยฐC at 33ยฐC ยฑ0.1ยฐC at 200ยฐC ยฑ0.2ยฐC at 350ยฐC |
| Radial uniformity | ยฑ0.01ยฐC at 33ยฐC ยฑ0.015ยฐC at 200ยฐC ยฑ0.02ยฐC at 350ยฐC |
| Loading effect (with a 6.35 mm reference probe and three 6.35 mm probes) | ยฑ0.015ยฐC Full Range |
| Hysteresis | 0.03 |
| Operating conditions | 0ยฐC to 50ยฐC, 0% to 90% RH (non-condensing) |
| Environmental conditions (for all specifications except temperature range) | 13ยฐC to 33ยฐC |
| Immersion (well) depth | 150 mm (5.9 in) |
| Insert OD | 25.3 mm (1.00 in) |
| Heating time | 5 min: 33ยฐC to 350ยฐC |
| Cooling time | 32 min: 350ยฐC to 33ยฐC 14 min: 350ยฐC to 100ยฐC |
| Resolution | 0.01ยฐ |
| Display | LCD, ยฐC or ยฐF user-selectable |
| Size (H x W x D) | 290 x 185 x 295 mm (11.4 x 7.3 x 11.6 in) |
| Weight | 7.3 kg (16 lb) |
| Power requirements | 100 V to 115 V (ยฑ10%), 50/60 Hz, 1400 W 230 V (ยฑ10%), 50/60 Hz, 1800 W |
| Computer interface | RS-232 interface |
| Calibration | Accredited calibration included |
| Automation | Use the 1586A Super-DAQ to automate temperature sensor calibration |
| -P specifications | |
| Built-in reference thermometer readout accuracy (4-Wire reference probe)1 | ยฑ0.010ยฐC at -25ยฐC ยฑ0.015ยฐC at 0ยฐC ยฑ0.020ยฐC at 50ยฐC ยฑ0.025ยฐC at 150ยฐC ยฑ0.030ยฐC at 200ยฐC ยฑ0.040ยฐC at 350ยฐC ยฑ0.050ยฐC at 420ยฐC ยฑ0.070ยฐC at 660ยฐC |
| Reference resistance range | 0 ohms to 400 ohms |
| Reference resistance accuracy2 | 0 ohms to 42 ohms: ยฑ0.0025 ohms 42 ohms to 400 ohms: ยฑ60 ppm of reading |
| Reference characterizations | ITS-90, CVD, IEC-751, Resistance |
| Reference measurement capability | 4-wire |
| Reference probe connection | 6-pin Din with Infocon Technology |
| Built-in RTD thermometer readout accuracy | NI-120: ยฑ0.015ยฐC at 0ยฐC PT-100 (385): ยฑ0.02ยฐC at 0ยฐC PT-100 (3926): ยฑ0.02ยฐC at 0ยฐC PT-100 (JIS): ยฑ0.02ยฐC at 0ยฐC |
| RTD resistance range | 0 ohms to 400 ohms |
| RTD resistance accuracyโก | 0 ohms to 25 ohms: ยฑ0.002 ohms 25 ohms to 400 ohms: ยฑ80 ppm of reading |
| RTD characterizations | ย PT-100 (385),(JIS),(3926), NI-120, Resistance |
| RTD measurement capability | 4-wire RTD (2-,3-wire RTD w\ Jumpers only) |
| RTD connection | 4 terminal input |
| Built-in TC thermometer readout accuracy | Type J: ยฑ0.7ยฐC at 660ยฐC Type K: ยฑ0.8ยฐC at 660ยฐC Type T: ยฑ0.8ยฐC at 400ยฐC Type E: ยฑ0.7ยฐC at 660ยฐC Type R: ยฑ1.4ยฐC at 660ยฐC Type S: ยฑ1.5ยฐC at 660ยฐC Type M: ยฑ1.4ยฐC at 660ยฐC Type L: ยฑ0.7ยฐC at 660ยฐC Type U: ยฑ0.75ยฐC at 600ยฐC Type N: ยฑ0.9ยฐC at 660ยฐC Type C: ยฑ1.1ยฐC at 660ยฐC |
| TC millivolt range | โ10 mV to 75 mV |
| Voltage accuracy | 0.025% of reading + 0.01 mV |
| Internal cold junction compensation accuracy | ยฑ0.35ยฐC (ambient of 13ยฐC to 33ยฐC) |
| TC connection | Small connectors |
| Built-in mA readout accuracy | 0.02% of reading + 2 mV |
| mA range | Cal 4-22 mA, Spec 4-24 mA |
| mA connection | 2 terminal input |
| Loop power function | 24 V DC loop power |
| Built-in electronics temperature coefficient (0ยฐC to 13ยฐC, 33ยฐC to 50ยฐC) | ยฑ0.005% of range per ยฐC |
| 1. The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. 2. Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. | |
Modellen: Fluke Calibration 9143 Field Metrology Well
Insert โAโ, imperial misc. holes
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Insert โBโ, imperial comparison holes
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Insert โCโ, 0.25-inch holes
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Insert โDโ, metric comparison holes
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Insert โEโ, metric misc. holes w/ 0.25-inch hole
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Insert โFโ, metric comparison misc. holes w/ 0.25-inch hole
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Fluke Calibration 9143-DW-156 Field Metrology Well
No insert
33ยฐC to 350ยฐC
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Insert removal tool
Insert โAโ, imperial misc. holes
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- 9930, Interface-it software
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Insert โBโ, imperial comparison holes
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Insert โCโ, 0.25-inch holes
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Insert โDโ, metric comparison holes
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Insert โEโ, metric misc. holes w/ 0.25-inch hole
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Insert โFโ, metric comparison misc. holes w/ 0.25-inch hole
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Fluke Calibration 9143-DW-P-156 Field Metrology Well
No insert
33ยฐC to 350ยฐC, w/ process electronics
Includes:
- Users manual
- Technical manual on CD
- Serial cable
- Report of calibration
- Test leads
- Insert removal tool
- 6-pin DIN connector for reference probe
Handleidingen + bronnen: Fluke Calibration 9143 Field Metrology Well
- 9142-B-P-156/AF | Gebruikershandleiding
- 9142-B-P-156/AF | Bijlage gebruikershandleiding
- 9142, 9143, 9144 | Gebruikershandleiding
- 9142, 9143, 9144 | Bijlage gebruikershandleiding
- 914X | Gebruikershandleiding
- 9142-B-P-156/AF | Naslaggids
- 9142-B-P-156/AF | Aanvulling referentiegids
- 9142/9143/9144 | Naslaggids
- 9142/9143/9144 | Aanvulling referentiegids
- Fluke 9144 Metrology Well Demo
- 914X Video Series - Conclusion
- 914X Video Series - Chapter 9
- 914X Video Series - Chapter 8
- 914X Video Series - Chapter 7
- 914X Video Series - Chapter 6
- 914X Field Metrology Wells Introduction Video
- How to Calibrate a Digital Thermometer with a Dry-Block Calibrator and with Freezing and Boiling Water
- Bringing Star Power to Earth
- Introduction to Dry Block Calibrators
- 914x Video Series Introduction
- 914X Video Series - Chapter 3
- 914X Video Series - Chapter 2
- 914X Video Series - Chapter 5
- 914X Video Series - Chapter 4