  • 320 x 240 resolution infrared camera
  • 3.6 inch LCD screen
  • Measure up to 550 °C
  • One-handed image capture, review and save capability

Key features

  • 320 x 240 resolution
  • 2 meter drop test
  • IR Fusion™ technology for context
  • Fixed focus
  • Measure up to 400 °C
  • Subject to Export Control

Product overview: Fluke TiS60+ Thermal Camera

 

Boost you or your team’s performance with 320 x 240 resolution. Infrared images taken with the TiS60+ capture smaller temperature differences from farther away. If you are new to thermal imaging or if your camera is being used by a team with varying levels of thermal imaging experience, the TiS60+ offers fixed focus with the ability to capture quality images from farther.

The TiS60+ allows you to see things that are invisible to the eye and reveal problems that cannot be detected with other technologies. It is a simple to use, dependable tool that the team can rely on.

  • Easy to use fixed focus
  • 3.5 inch LCD screen
  • One-handed image capture, review and save capability
  • Fluke Connect™ compatibility for sharing wirelessly

Often the next big challenge with infrared images is to make sure that the images taken by the team can quickly be added to work orders. The TiS60+ features IR Photo Notes making this easy. They give the camera operator a simple way to add pictures associated with the image documenting the equipment name or the room location associated with the thermal image so that the person creating the work order can send the technicians to the right location for repairs.

Be prepared with everything you need to establish a baseline for your equipment, establish a preventive maintenance program and set standard work. The Fluke TiS60+ gives you the thermal data needed to get the job done.

What's in the box:

  • Thermal imager
  • AC power supply (including universal AC adapters)
  • Two-bay smart battery charger
  • Two rugged lithium ion smart batteries
  • USB cable
  • 4 GB micro SD card
  • Rugged hard carrying case with soft transport bag and adjustable hand strap
  • Available by free download: Fluke Connect™ software and user manual

Specifications: Fluke TiS60+ Thermal Camera

Key features
IFOV (spatial resolution)1.86 mRad, D:S 532:1
Infrared resolution320 x 240 (76,800 pixels)
Field of view34.1 °H x 25.6 °H
Focus systemFixed
Minimum focus distance46 cm (18 in)
Ruggedized display3.5 inch (8.9 cm landscape) 320 x 240 LCD
Ergonomic designDesigned for one-handed use
Temperature measurement
Temperature range (not calibrated below -10 °C)-20 °C to 400 °C (-4 °F to 752 °F)
Accuracy± 2 °C or 2 % (at 25 °C nominal, whichever is greater)
Thermal sensitivity (NETD)≤ 0.045 °C at 30 °C target temp (45 mK)
On-screen emissivity correctionYes (both value and table)
On-screen reflected background temperature compensationYes
On-screen transmission correctionNo
Wireless connectivity
Wireless connectivityYes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available)
Fluke™ Connect app compatibleYes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing
Fluke Connect Assets optional softwareYes*, assign images to assets and create work orders. Easily compare measurement types - whether mechanical, electrical or infrared images - in one location
IR Fusion® technology
IR Fusion® technologyYes
AutoBlend™ modeYes
Picture-In-Picture (PIP)Yes
Built-in digital camera (visible light)5MP
Level and span
Level and spanSmooth auto and manual scaling
Fast auto-rescale in manual modeYes
Minimum span (in manual mode)2.5 °C (4.5 °F)
Minimum span (in auto mode)5 °C (9.0 °F)
Data storage and image capture
Extensive memory optionsInternal 4GB memory and 4GB micro SD card
Image capture, review, save mechanismOne-handed image capture, review, and save capability
Image file formatsNon-radiometric BMP or JPEG or fully-radiometric is2
Memory reviewYes
SoftwareFluke Connect desktop software - full analysis and reporting software with access to the Fluke Connect system
Analyze and store radiometric data on a PCYes
Export file formats with Fluke Connect softwareis2, BMP, GIF, JPEG, PNG, TIFF
Voice annotation60 seconds maximum recording time per image; reviewable playback on camera; Bluetooth headset required (sold separately)
IR-PhotoNotesYes - 3 images
Auto capture (temperature and interval)Yes
Battery
Batteries (field-replaceable, rechargeable)Two lithium ion smart battery pack with five-segment LED display to show charge level
Battery life4 hours continuous use per battery pack
Battery charging time2.5 hours to full charge
Battery charging systemTwo-bay battery charger or in-imager charging. Optional 12 V automotive charging adapter
AC operationAC operation with included power supply (100 V AC to 240 V AC, 50/60 Hz)
Power savingUser selectable
Color palettes
Standard palettes8: Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted
Ultra contrast palettes8: Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra
General specifications
Laser pointerYes
Frame rate< 9 Hz or 30 Hz
Color alarmsHigh temperature, low temperature, isotherms (within range)
Infrared spectral band7.5 μm to 14 μm
Operating temperature-10 °C to +50 °C (14 °F to 122 °F)
Storage temperature-20 °C to +50 °C (-4 °F to 122 °F) without batteries
Relative humidity10 % to 95 %, non-condensing
Center-point temperature measurementYes
Spot temperatureHot and cold spot markers
User-definable spot markers3
User defined measurement boxesExpandable-contractible measurement box
Hard caseRugged hard carrying case with soft transport bag, including adjustable strap
Safety standardsIEC 61010-1: Overvoltage category II, Pollution Degree 2
Electromagnetic compatibilityIEC 61326-1: Basic EM environment. CISPR 11: Group 1, Class A
Australian RCMRCM IEC 61326-1
US FCCEN61326-1; FCC Part 5, EN 55011: Class A, EN 61000-4-2, EN 61000-4-3
Vibration2G, IEC 68-2-6
Shock25G, IEC 68-2-29
DropEngineered to withstand 2 meter (6.5 feet) drop
Sized (H x W x L)26.7 cm x 10.1 cm x 14.5 cm (10.5 in x 4.0 in x 5.7 in)
Weight (battery included)0.72 kg (1.6 lb.)
Enclosure ratingIP54 (protected against dust, limited ingress; protection against water spray from all directions)
WarrantyTwo-years (standard)
Recommended calibration cycleTwo-years (assumes normal operation and normal aging)
Supported languagesCzech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish
RoHS compliantYes

Models: Fluke TiS60+ Thermal Camera

FLK-TIS60+ 30HZ

Fluke TiS60+ Infrared Camera 30Hz


Buy it

Includes:

  • Thermal imager
  • AC power supply (including universal AC adapters)
  • Two-bay smart battery charger
  • Two rugged lithium ion smart batteries
  • USB cable
  • 4 GB micro SD card
  • Rugged hard carrying case with soft transport bag and adjustable hand strap
  • Available by free download: Fluke Connect™ software and user manual
FLK-TIS60+ 9HZ

Fluke TiS60+ Infrared Camera 9 Hz


Buy it

Includes:

  • Thermal imager
  • AC power supply (including universal AC adapters)
  • Two-bay smart battery charger
  • Two rugged lithium ion smart batteries
  • USB cable
  • 4 GB micro SD card
  • Rugged hard carrying case with soft transport bag and adjustable hand strap
  • Available by free download: Fluke Connect™ software and user manual

How do i get the activation code so that i can connect my TIS60+ to Fluke Connect App?

Asked by: DJones
For Fluke Connect help, please reach out to flukeconnectsupport@fluke.com.
Answered by: FlukeCorporation
Date published: 2024-04-19

Is it intrinsically safe/flameproof?

Asked by: parijat
The TiS60+ is not an intrinsically safe thermal imager. Fluke does not manufacture an intrinsically safe thermal imager.
Answered by: Fluke Staff
Date published: 2023-05-01
  • y_2024, m_10, d_24, h_5CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_en_US, sid_4623544877108, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 23.83ms
  • QUESTIONS, PRODUCT
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.77ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat