Fluke 719Pro Electric Pressure Calibrator

Fluke 719Pro Electric Pressure Calibrator is rated 3.4 out of 5 by 5.
  • y_2024, m_10, d_31, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_3840953679924, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 174.55ms
  • REVIEWS, PRODUCT
  • Fluke 719Pro Electric Pressure Calibrator 1
  • Fluke 719Pro Electric Pressure Calibrator 2
  • Fluke 719Pro Electric Pressure Calibrator 3

Key features

  • Unique integrated electric pump for one handed pressure calibration
  • Test pressure switches easily with easy-to-use switch test function
  • Precision pressure adjust vernier for easy and accurate pressure calibration
  • Ideal accuracy and performance (0.025%) for reference class transmitter calibration
  • 30 psi, 150 psi and 300 psi pressure ranges
  • Programmable pressure calibrator pump limit:
    • Eliminates over-pressurization
    • Allows the user to program target pressures for pumping
  • Extended pressure measurement range with any of 29 750P Pressure Modules
  • Pump cleanout ports reduce pump failures from moisture and fluid damage
  • Fluid trap included with the unit to mitigate chance of fluid damage in at-risk applications
  • Precision temperature measurement with optional RTD probe

Product overview: Fluke 719Pro Electric Pressure Calibrator

Fluke Premium Care eligible

When you invest in your Fluke test tools, you want your money to go as far as possible. Fluke Premium Care is a paid offering that provides coverage above and beyond the original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair.

Learn more

Fluke 719Pro Electric Pressure Calibrator sources, simulates, and measures mA signals and more

The 719Pro includes a full functioning loop calibrator that sources, simulates and measures mA signals and more making it the ideal test tool for calibrating high accuracy transmitters, pressure switches and pressure gauges.

Get the ultimate in measurement flexibility with the large backlit screen, which displays three parameters at once:

  • Pressure measurement from internal or external sensor
  • Sourced/simulated or measured mA values
  • Temperature measured by optional RTD probe

Specifications: Fluke 719Pro Electric Pressure Calibrator

Measurement
Fluke-719Pro-30GRange-12 to 30 psi / -0.8 to 2 bar
Resolution0.001 psi / 0.0001 bar
Fluke-719Pro-150GRange-12 to 150 psi / -0.8 to 10 bar
Resolution0.01 psi / 0.001 bar
Fluke-719Pro-300GRange-12 to 300 psi / -0.8 to 20 bar
Resolution0.01 psi / 0.001 bar
Accuracy±0.025% of full scale, 6 months
±0.035% of full scale, 1 year
Temperature effect (all ranges)Add ±0.002% F.S./°C for temps outside of 15°C to 35°C
Dry air and non-corrosive gas only
No effect on accuracy on all functions from 15°C to 35°C
FunctionRangeResolutionAccuracy (1 year)
mA DC (simulation and measurement)0-24 mA DC0.001 mA±0.015% of reading ±2 counts
1000 ohm maximum load in mA source, 26 V DC maximum voltage in mA simulate
Volts DC (measurement only)30 V DC0.001 V±0.015% of reading ±2 counts
No AC voltage measurement, do not exceed 30 V DC
Temperature (measurement only, Pt100 RTD)-50 to 150°C
(-50°F to 302°F)
0.01°C
0.01°F
Temperature ±0.1°C (0.2°F)
±0.25°C (±0.45°F) combined uncertainty when using 720 RTD probe (optional accessory)
Loop power supply24 V DCN/A24 mA at 24 V
Temperature effect (all functions)--Add ±0.002% F.S./°C for temps outside of 15°C to 35°C
No effect on accuracy on all functions from 15°C to 35°C
Environmental
Operating temperature-10°C to +50°C
Storage temperature (with batteries)Per battery manufacturer's specification within storage specification below
Storage temperature (without batteries)-20°C to +60°C
Power Requirements
BatteryEight (8) standard Alkaline AA batteries
Battery life300 pump cycles to 150 psi minimum; 1000 pump cycles to 30 psi; 100 pump cycles to 300 psi minimum
Physical
Dimensions (H x W x D)24.13 x 11.18 x 7 cm (9.5 x 4.4 x 2.8 in)
WeightWith holster 1.2 kg (2.5 lb)
Connections
Pressure1/8 inch female NPT
ElectricalStandard banana jacks
RTD4 pin miniature circular
External module6 pin miniature circular
Engineering Units (Configurable)
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4°C, cmH2O @ 20°C, mH2O @ 4°C, mH2O @ 20°C, inH2O @ 4°C, inH2O @ 20°C, inH2O @ 60°F, mmHg @ 0°C, inHg @ 0°C, ftH2O @ 4°C, ftH2O @ 20°C, ftH2O @ 60°F

Models: Fluke 719Pro Electric Pressure Calibrator

Fluke 719Pro 30G
Fluke 719Pro-30G Electric Pressure Calibrator
30 psig

Buy it

Includes:

  • Test leads with alligator clips
  • Printed user's manual and user's manual on CD-ROM in 14 languages
  • Fluid trap
  • Carrying case
  • 1/4 inch NPT to 1/4 inch ISO adapter
  • Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
  • Traceable Certificate of Calibration
Fluke 719Pro 150G
Fluke 719Pro-150G Electric Pressure Calibrator
150 psig

Buy it

Includes:

  • Test leads with alligator clips
  • Printed user's manual and user's manual on CD-ROM in 14 languages
  • Fluid trap
  • Carrying case
  • 1/4 inch NPT to 1/4 inch ISO adapter
  • Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
  • Traceable Certificate of Calibration
Fluke 719Pro 300G
Fluke 719Pro-300G Electric Pressure Calibrator
300 psig

Buy it

Includes:

  • Test leads with alligator clips
  • Printed user's manual and user's manual on CD-ROM in 14 languages
  • Fluid trap
  • Carrying case
  • 1/4 inch NPT to 1/4 inch ISO adapter
  • Accessory hose kit with (2) 1/8 inch quick fit adapters and 1 meter of hose
  • Traceable Certificate of Calibration
FPC1S-FLUKE71X-1

Premium Care 1-Year Standard Plan for Fluke 719Pro, 719, and 718


Buy it

Includes:

  • Premium Care 1-Year Standard Plan
FPC3S-FLUKE71X-1

Premium Care 3-Year Standard Plan for Fluke 719Pro, 719, and 718


Buy it

Includes:

  • Premium Care 3-Year Standard Plan
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 25.81ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Rated 1 out of 5 by from 719 pro I will never buy another fluke product. i spent over 5k on a 719-300 pro unit broke after 3 weeks. I'm still trying to send this thing back to get repaired but they just transfer me from department to department. unbelievable
Date published: 2023-05-17
Rated 5 out of 5 by from Great Device Great device, It was just what we were looking for
Date published: 2022-02-14
Rated 5 out of 5 by from Excellent calibration tool! I am a instrument calibration technician for a process engineering firm. I test and calibrate hundreds of in process pressure devices per year. The 719 Pro has been a true help to my productivity and has saved my hand from wearing out, when you do 30 to 50 pressure devices in a day it really helps to have the electric pump. I have even been amazed at the life of the batteries.
Date published: 2019-08-15
Rated 2 out of 5 by from I wanted to like this and in some ways I still do. The features of this pressure calibrator are great and the ease of use is excellent; however... It was always frustrating because it would sometimes hold pressure and other times it wouldn't. In those cases my applied pressure would be steadily decreasing which made calibrations difficult or impossible. It was sent back to Fluke for repair once and the issue was not resolved. I got around the issue by purchasing a Fluke 750P05 pressure module and a hand pump which worked great until two weeks ago when I was on a jobsite and the connection point where the pressure module plugs into the 719PRO came loose and was coming out of the 719PRO when I attempted to unplug the cable. I attempted to secure the connection points by putting a spacer over the unused connection point and holding it in place with duct tape but later that day my pressure module was losing connection to the 719PRO when plugged in. I'm now planning to send it back to Fluke for repair a second time in I think 4 years of ownership and I only use the calibrator several times a month.
Date published: 2019-02-09
Rated 4 out of 5 by from good intrument works very well. a couple of minor improvements would be to ad ft h2o as a unit and to have a port for an ac adapter in addition to the battery pack.
Date published: 2017-11-01
  • y_2024, m_10, d_31, h_6
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.42
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_3840953679924, prod, sort_[SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_fluke
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 23.19ms
  • REVIEWS, PRODUCT
Please enable cookies to view product reviews.