Key features

Precision Pressure Measurement for 75X and 720 Series Calibrators

The 750P Series Pressure Modules are the ideal pressure modules to enable gage, differential and absolute pressure measurement with Fluke 750 and 740 series DPCs and 725, 726 MPCs to measure pressure.

  • Up to 0.01% reference uncertainty
  • 6-month and 1-year specifications
  • Temperature compensated 0°C to 50°C
  • Digital communication to calibrators, no analog losses or errors
  • Broad selection of ranges
  • Gage, differential, dual range, absolute and vacuum measurement models
  • Eight (8) Intrinsically Safe models that are certified to:
    • NEC-500: Class I Div 1, Groups A-D, Ga
    • ATEX: II 1 G Ex ia IIC T4 Ga
    • IECEx: Ex ia IIC T4 Ga
    • *All certifications: Ta = -10 °C to +50 °C
Get a free demo

Product overview: Fluke 750P Series Pressure Modules

A Complete Family of Pressure Modules

A family of 50 pressure modules covers pressure calibrations from 0 to 1 inH20 to 10,000 psi (2.5 mBar to 690 bar).

Gage pressure modules have one pressure fitting and measure the pressure with respect to atmospheric pressure. Differential pressure modules have two pressure fittings and measure the difference between the applied pressure on the high fitting versus the low fitting. Each module is clearly labeled for pressure range and media compatibility. All modules include NPT, metric (BSP) and M20 adapters. Compatible with all documenting, multifunction and pressure calibrators (including: Fluke 754, 752, 726, 725, 721, 719Pro, 719, 717 and legacy 741, 743, 744, 701 and 702 calibrators).

Quick and Easy Measurements

Fluke 750P Series Pressure Modules are easy to use. To measure pressure, connect the pressure module to a pressure source or hand pump and then connect the pressure module cable to the calibrator. Apply pressure from the pressure source and it is displayed digitally on the calibrator. At the touch of a button, the pressure may be displayed in up to 11 different engineering units. When used with the 750 Series Documenting Process Calibrators, pressure readings can be date/time stamped and stored electronically for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.

Choose from:

  • Differential modules
  • Gage modules
  • High pressure modules
  • Absolute modules
  • Vacuum modules
  • Dual range modules
  • Reference modules
  • Intrinsically safe modules

Other useful features:

  • Communicates measurements to calibrators in digital form, eliminating errors due to poor connections and electrical interference
  • Offers broad selection of ranges
  • Enables gage, differential, dual range, absolute and vacuum measurement models
  • Features a stainless steel diaphragm to isolate the sensor (in many models)
  • Features a rugged urethane overmolding to protect against shock being dropped and also seals against dirt, dust, and moisture.

Specifications: Fluke 750P Series Pressure Modules

Differential Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750P00 0 to 1 inH2O (0 to 2.5 mBar) 30X Dry air Dry air
750P017 0 to 10 inH2O (0 to 25 mBar) 3X Dry air Dry air
750P02 0 to 1 psi (0 to 70 mBar) 3X Dry air Dry air
750P22 0 to 1 psi (0 to 70 mBar) 3X 316 SS Dry air
750P03 0 to 5 psi (0 to 350 mBar) 3X Dry air Dry air
750P23 0 to 5 psi (0 to 350 mBar) 4X 316 SS Dry air
750P04 0 to 15 psi (0 to 1 bar) 3X Dry air Dry air
750P247 0 to 15 psi (0 to 1 bar) 4X 316 SS Dry air
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750P00 ±0.15% ±0.3% ±0.35% ±0.25% ±0.30%
750P017 ±0.1% ±0.2% ±0.3% ±0.15% ±0.25%
750P02 ±0.050% ±0.1% ±0.15% ±0.075% ±0.125%
750P22 ±0.050% ±0.1% ±0.15% ±0.075% ±0.125%
750P03 ±0.02% ±0.04% ±0.05% ±0.035% ±0.04%
750P23 ±0.02% ±0.04% ±0.05% ±0.035% ±0.04%
750P04 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P247 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
Gage Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750P057 0 to 30 psi (0 to 2 bar) 4X 316 SS N/A
750P067 0 to 100 psi (0 to 7 bar) 4X 316 SS N/A
750P277 0 to 300 psi (0 to 20 bar) 4X 316 SS N/A
750P07 0 to 500 psi (0 to 35 bar) 4X 316 SS N/A
750P08 0 to 1000 psi (0 to 70 bar) 3X 316 SS N/A
750P097 0 to 1500 psi (0 to 100 bar) 3X 316 SS N/A
750P2000 0 to 2000 psi (0 to 140 bar) 3X 316 SS N/A
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750P057 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P067 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P277 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P07 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P08 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P097 ±0.0175% ±0.035% ± 0.045% ±0.03% ±0.04%
750P2000 ±0.0175% ±0.035% ± 0.045% ±0.03% ±0.04%
High Pressure Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750P29 0 to 3000 psi (0 to 200 bar) 3X 316 SS N/A
750P30 0 to 5000 psi (0 to 340 bar) 3X 316 SS N/A
750P31 0 to 10000 psi (0 to 700 bar) 2X 316 SS N/A
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750P29 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P30 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P31 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
Absolute Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750PA3 0 to 5 psia (0 to 350 mBar) 4X 316 SS N/A
750PA47 0 to 15 psia (0 to 1 bar) 4X 316 SS N/A
750PA5 0 to 30 psia (0 to 2 bar) 4X 316 SS N/A
750PA6 0 to 100 psia (0 to 7 bar) 4X 316 SS N/A
750PA27 0 to 300 psia (0 to 20 bar) 4X 316 SS N/A
750PA7 0 to 500 psia (0 to 35 bar) 4X 316 SS N/A
750PA8 0 to 1000 psia (0 to 70 bar) 3X 316 SS N/A
750PA9 0 to 1500 psia (0 to 100 bar) 3X 316 SS N/A
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750PA3 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA47 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA5 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA6 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA27 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA7 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA8 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA9 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
Vacuum Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750PV3 -5 psi (-350 mBar) 4X 316 SS Dry air
750PV4 -15 psi (-1 bar) 4X 316 SS Dry air
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750PV3 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PV4 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
Dual Range Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750PD2 -1 to 1 psi (-70 to 70 mBar) 4X 316 SS Dry air
750PD3 -5 to 5 psi (-350 to 350 mBar) 4X 316 SS Dry air
750PD10 -10 to 10 psi (-700 to 700 mBar) 4X 316 SS Dry air
750PD4 -15 to 15 psi (-1 to 1 bar) 4X 316 SS Dry air
750PD5 -15 to 30 psi (-1 to 2 bar) 4X 316 SS
750PD50 -15 to 50 psi (-1 to 3.5 bar) 4X 316 SS
750PD6 -15 to 100 psi (-1 to 7 bar) 4X 316 SS
750PD7 -15 to 200 psi (-1 to 14 bar) 4X 316 SS
750PD27 -15 to 300 psi (-1 to 20 bar) 4X 316 SS
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750PD2 ±0.05% ±0.1% ±0.15% ±0.075% ±0.125%
750PD3 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PD10 ±0.025% ±0.05% ±0.07% ±0.04% ±0.06%
750PD4 ±0.0175% ±0.035% ±0.045% ±0.03% ± 0.04%
750PD5 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD50 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD6 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD7 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD27 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
Reference Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750R045 0 to 15 psi (0 to 1 bar) 3X Dry air Dry air
750R065 0 to 100 psi (0 to 7 bar) 4X 316 SS
750R27 0 to 300 psi (0 to 20 bar) 4X 316 SS
750R07 0 to 500 psi (0 to 35 bar) 4X 316 SS
750R085 0 to 1000 psi (0 to 70 bar) 3X 316 SS
750R29 0 to 3000 psi (0 to 200 bar) 3X 316 SS
750R30 0 to 5000 psi (0 to 340 bar) 3X 316 SS
750R315 0 to 10000 psi (0 to 700 bar) 2X 316 SS
750RD5 -15 to 30 psi (-1 to 2 bar) 4X Dry air
750RD65 -12 to 100 psi (-0.8 to 7 bar) 4X 316 SS
750RD27 -12 to 300 psi (-0.8 to 20 bar) 4X 316 SS
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C)
Total uncertainty
1-year1
Total uncertainty
6-month
(15-35°C)
Total uncertainty
6-month1
750R045 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R065 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R27 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R07 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R085 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R29 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R30 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R315 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750RD5 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750RD65 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750RD27 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
1. Total uncertainty, % of full span for temperature range 0°C to +50°C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one year interval. No 6 month specification available for range -10°C to 0°C. 
2. “Non-corrosive gasses” indicates Dry air or non-corrosive gas as compatible media. “Stainless Steel 316-SS” indicates media compatible with Type 316 Stainless Steel. 
3. Specifications % of Full Span unless otherwise noted. 
4. Reference Uncertainty is the specification for as left data for 24 hours. 
5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification. 
6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure. 
7. Intrinsically Safe pressure module available in this pressure range.

Models: Fluke 750P Series Pressure Modules

Fluke 750P00
Fluke 750P00 Differential Pressure Module
0 to 1 inH2O (0 to 2.5 mBar), (0 to 0.25 kPa)
Buy it

Includes:

  • Pressure module
  • traceable calibration certificate
  • adapters
  • manual
Fluke 750P01
Fluke 750P01 Differential Pressure Module
0 to 10 inH2O (0 to 25 mBar), (0 to 2.5 kPa)
Buy it
Fluke 750P02
Fluke 750P02 Differential Pressure Module
0 psi to 1 psi (0 to 70 mBar), (0 to 7 kPa)
Buy it
Fluke 750P03
Fluke 750P03 Differential Pressure Module
0 psi to 5 psi (0 to 350 mBar), (0 to 35 kPa)
Buy it
Fluke 750P04
Fluke 750P04 Differential Pressure Module
0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
Buy it
Fluke 750P22
Fluke 750P22 Differential Pressure Module
0 psi to 1 psi (0 to 70 mBar), (0 to 7 kPa)
Buy it
Fluke 750P23
Fluke 750P23 Differential Pressure Module
0 psi to 5 psi (0 to 350 mBar), (0 to 35 kPa)
Buy it
Fluke 750P24
Fluke 750P24 Differential Pressure Module
0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
Buy it
Fluke 750P05
Fluke 750P05 Gage Pressure Module
0 psi to 30 psi (0 to 2 bar), (0 to 200 kPa)
Buy it
Fluke 750P06
Fluke 750P06 Gage Pressure Module
0 psi to 100 psi (0 to 7 bar), (0 to 700 kPa)
Buy it
Fluke 750P07
Fluke 750P07 Gage Pressure Module
0 psi to 500 psi (0 to 35 bar), (0 to 3500 kPa)
Buy it
Fluke 750P08
Fluke 750P08 Gage Pressure Module
0 psi to 1000 psi (0 to 70 bar), (0 to 7000 kPa)
Buy it
Fluke 750P09
Fluke 750P09 Gage Pressure Module
0 psi to 1500 psi (0 to 100 bar), (0 to 10 MPa)
Buy it
Fluke 750P27
Fluke 750P27 Gage Pressure Module
0 psi to 300 psi (0 to 20 bar), (0 to 2000 kPa)
Buy it
Fluke 750P2000
Fluke 750P2000 Gage Pressure Module
0 psi to 2000 psi (0 to 140 bar), (0 to 14 MPa)
Buy it
Fluke 750P29
Fluke 750P29 High Pressure Module
0 psi to 3000 psi (0 to 200 bar), (0 to 20 MPa)
Buy it
Fluke 750P30
Fluke 750P30 High Pressure Module
0 psi to 5000 psi (0 to 340 bar), (0 to 34 MPa)
Buy it
Fluke 750P31
Fluke 750P31 High Pressure Module
0 psi to 10000 psi (0 to 700 bar), (0 to 70 MPa)
Buy it
Fluke 750PA3
Fluke 750PA3 Absolute Pressure Module
0 psi to 5 psi (0 to 350 mBar), (0 to 35 kPa)
Buy it
Fluke 750PA4
Fluke 750PA4 Absolute Pressure Module
0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
Buy it
Fluke 750PA5
Fluke 750PA5 Absolute Pressure Module
0 psi to 30 psi (0 to 2 bar), (0 to 200 kPa)
Buy it
Fluke 750PA6
Fluke 750PA6 Absolute Pressure Module
0 psi to 100 psi (0 to 7 bar), (0 to 700 kPa)
Buy it
Fluke 750PA7
Fluke 750PA7 Absolute Pressure Module
0 psi to 500 psi (0 to 35 bar), (0 to 3500 kPa)
Buy it
Fluke 750PA8
Fluke 750PA8 Absolute Pressure Module
0 psi to 1000 psi (0 to 70 bar), (0 to 7000 kPa)
Buy it
Fluke 750PA9
Fluke 750PA9 Absolute Pressure Module
0 psi to 1500 psi (0 to 100 bar), (0 to 10 MPa)
Buy it
Fluke 750PA27
Fluke 750PA27 Absolute Pressure Module
0 psi to 300 psi (0 to 20 bar), (0 to 2000 kPa)
Buy it
Fluke 750PV3
Fluke 750PV3 Vacuum Pressure Module
-5 psi (-350 mBar), (-35 kPa)
Buy it
Fluke 750PV4
Fluke 750PV4 Vacuum Pressure Module
-15 psi (-1 bar), (-100 kPa)
Buy it
Fluke 750PD2
Fluke 750PD2 Dual Pressure Module
1 psi to 1 psi (-70 to 70 mBar), (-7 to 7 kPa)
Buy it
Fluke 750PD3
Fluke 750PD3 Dual Pressure Module
-5 psi to 5 psi (-350 to 350 mBar), (-35 to 35 kPa)
Buy it
Fluke 750PD4
Fluke 750PD4 Dual Pressure Module
-15 psi to 15 psi (-1 to 1 bar), (-100 to 100 kPa)
Buy it
Fluke 750PD5
Fluke 750PD5 Dual Pressure Module
-15 psi to 30 psi (-1 to 2 bar), (-100 to 200 kPa)
Buy it
Fluke 750PD6
Fluke 750PD6 Dual Pressure Module
-15 psi to 100 psi (-1 to 7 bar), (-100 to 700 kPa)
Buy it
Fluke 750PD7
Fluke 750PD7 Dual Pressure Module
-15 psi to 200 psi (-1 to 14 bar), (-100 to 1400 kPa)
Buy it
Fluke 750PD10
Fluke 750PD10 Dual Pressure Module
-10 psi to 10 psi (-0.7 to 0.7 bar), (-70 to 70 kPa)
Buy it
Fluke 750PD27
Fluke 750PD27 Dual Pressure Module
-15 psi to 300 psi (-1 to 20 bar), (-100 to 2000 kPa)
Buy it
Fluke 750PD50
Fluke 750PD50 Dual Pressure Module
-15 psi to 50 psi (-1 to 3.5 bar), (-100 to 350 kPa)
Buy it
Fluke 750R04
Fluke 750R04 Reference Pressure Module
0 psi to 15 psi (0 to 1 bar), (0 to 100 kPa)
Buy it
Fluke 750R06
Fluke 750R06 Reference Pressure Module
0 psi to 100 psi (0 to 7 bar), (0 to 700 kPa)
Buy it
Fluke 750R07
Fluke 750R07 Reference Pressure Module
0 psi to 500 psi (0 to 35 bar), (0 to 3500 kPa)
Buy it
Fluke 750R08
Fluke 750R08 Reference Pressure Module
0 psi to 1000 psi (0 to 70 bar), (0 to 7000 kPa)
Buy it
Fluke 750R27
Fluke 750R27 Reference Pressure Module
0 psi to 300 psi (0 to 20 bar), (0 to 2000 kPa)
Buy it
Fluke 750R29
Fluke 750R29 Reference Pressure Module
0 psi to 3000 psi (0 to 200 bar), (0 to 20 MPa)
Buy it
Fluke 750R30
Fluke 750R30 Reference Pressure Module
0 psi to 5000 psi (0 to 340 bar), (0 to 34 MPa)
Buy it
Fluke 750R31
Fluke 750R31 Reference Pressure Module
0 psi to 10000 psi (0 to 700 bar), (0 to 70 MPa)
Buy it
Fluke 750RD5
Fluke 750RD5 Reference Pressure Module
-15 psi to 30 psi (-1 to 2 bar), (-100 to 200 kPa)
Buy it
Fluke 750RD6
Fluke 750RD6 Reference Pressure Module
-12 psi to 100 psi (-0.8 to 7 bar), (-80 to 700 kPa)
Buy it
Fluke 750RD27
Fluke 750RD27 Reference Pressure Module
-12 psi to 300 psi (-0.8 to 20 bar), (-80 to 2000 kPa)
Buy it