Fluke FEV300 EV Charging Station Test Adapter

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 72.49ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • Fluke EV Charging Station Test Adapter Kit with Type 2 Connector
  • Fluke EV Charging Station Test Adapter Kit with Type 2 Connector
  • Fluke EV Charging Station Test Adapter Kit with Type 2 Connector
  • Fluke EV Charging Station Test Adapter Kit with Type 2 Connector
  • Fluke EV Charging Station Test Adapter Kit with Type 2 Connector

Key features

  • PE conductor can be tested for possible presence of dangerous voltage against earth
  • Perform Cable Simulation with the PP State rotary switch simulating current capabilities of charging cables
  • Perform Vehicle Simulation testing various charging states 
  • Simulate PE error (Earth fault)
  • Test in accordance with IEC/EN 61851-1 and IEC/HD 60364-7-722

Sale ends soon.

Shop now!

DAYS
HR
MIN
SEC
In stock
A$1588.40
Tax included where applicable
Genuine Fluke Product
Free shipping

Product overview: Fluke FEV300 EV Charging Station Test Adapter

The FEV300 test adapter kit with Type 2 connector is designed to test function and safety of charging stations mode 3 for AC charging. The adapter imitates an electric vehicle and opens up a charging cycle, activating voltage and current output, allowing you to conduct tests in combination with appropriate test instruments like an installation tester (Fluke 1664 FC) and/or a ScopeMeter® (Fluke 120B Series). With the adapter kit, charging stations can be tested in accordance with IEC/EN 61851-1 and IEC/HD 60364-7-722.

Simplicity and convenience using an all in one adapter

To connect to an EV charging station Type 2 with socket outlet, or to connect to an EV charging station Type 2 with vehicle connector, use the FEV300-CON-TY2 Type 2 Plug. Perform a variety of tests including ground fault checks, insulation of wires, measuring voltage and duty cycle to see max current available for charging all in one adapter that safely integrates with the Fluke portfolio of test and measurement tools. The FEV300 allows you to simulate CP (E) and PE (Earth Fault) error and includes separate phase indication by three LED lamps for easy check if voltage is present. There is no need to bring an electric vehicle onsite for charging station troubleshooting: the adapter acts as an electric vehicle when connected to a charging station for easy performance and maintenance testing.

Compatible products:

What's in the box:

  • FEV300/BASIC Test Adapter
  • FEV300-CON-TY2 Type 2 Plug
  • Carrying case

Specifications: Fluke FEV300 EV Charging Station Test Adapter

General features
Input voltageUp to 250 V (single phase system) / up to 480 V (three phase system), 50/60 Hz, max 10 A
Internal power consumption3 W max.
FEV300-CON-TY2 PlugAC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed cable with vehicle connector (type 2, 7P three-phase)
FEV300-CON-TY1 PlugAC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with vehicle connector (type 1, 5P single-phase)
Dimensions (H × W × D)110  × 45  × 220 mm length without connection cable and test cable
Weight (including type 1 or type 2 connection cable)Approx. 1 kg
Safety standardsIEC/EN 61010-1, pollution degree 2
IEC/EN 61010-2-030, CAT II 300 V, protection class II
Ingress protectionIEC 60529: IP54 (housing)
IEC 60529: IP54 (sockets with protection caps in place, connectors in connected condition or with protection caps in place, otherwise IP20)
Operating temperature-20 °C to 40 °C
Storage temperature-20 °C to 50 °C
Operating humidity range10 % to 85 % relative humidity non-condensing
Storage relative humidity0 % to 85 % non-condensing
Operating altitude2000 m max.
Functions
PE Pre-TestVisible indication >50 V AC/DC between PE conductor and touch sensor
PP SimulationOpen, 13 A, 20 A, 32 A, 63 A
CP StatesState A, B, C, D
CP Error state “E”On/off (CP signal short-circuited to PE)
PE Error state "F" (Earth fault)On/off (interruption of PE conductor)
Outputs (for test purpose only)
Measuring terminals L1, L2, L3, N, PEMax. 250/480 V, max. 10 A
CP signal output terminalsApprox. +/-12 V
Caution: In case of wrong wiring or error of the charging station these terminals may be hazardous.
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 63.82ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 21.8ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.