TITLE | USE WITH |
6003A | All |
The updating of embedded software should only be performed after given specific instructions to do so from Technical Support or a Fluke Calibration Authorized Service Center. If the update isn't performed properly, your product may be inoperable until it is. | |
Instructions to update by USB | |
Installation Put the CD into the computer, wait for autorun and select “Software installation” and “Uploader” or start direct “install\freeware\uploader”. Uninstall Uploader To remove the Uploader software from your system, you should run “uninstall” from “Programs” ("Start -> Programs -> Uploader -> Uninstall Uploader" from the Windows Start menu). Uploading Firmware 1. Connect the calibrator to the computer using an RS232 cable. 2. Select RS232 in the instrument menu as the active interface and set the baud rate to 9600 Bd. 3. Start the Uploader “Start->Program files->Uploader->Uploader.exe”. The following screen will appear: ![]() 4. Select computers port (COM1 … COM32) and the source file. The source file is a data file that contains the new firmware with the extension “.upl”. 5. Press “Connect”. The following screen will appear: ![]() 6. It is recommended to keep the transfer speed as-is and press “Upload” (in the case of an unsuccessful upload, reduce the transfer speed and try again). The following screen will appear: ![]() 7. Uploader automatically reloads all internal programs step by step. 8. After successful upload, the Uploader displays the following: ![]() Problems While Uploading New Firmware In the case that the upload does not finish properly (power supply disconnection, failed communication, etc.) the instrument will no longer contain internal software. Switch the instrument’s power supply off, wait approximately 10 seconds, and switch it on again. The instrument will display the message “Internal SW damaged!”. Repeat the procedure upload. The instrument is switched to RS232, 9600Bd mode automatically. | |
Updates Include: | |
Version 1.048 (2019 Oct. 25) Fix: Bug fixed that caused the GUI to lock up when too many characters were entered into the calibration password field. |
- 製品情報
- 3 特徴
- 2 アクセサリー
- 3 建物のインフラ
- 12 電気試験
- 3 音響画像と赤外線画像
- 2 温度測定
- 2 ネットワーク・ケーブル・テスター
- 1 位置合わせツール
- 9 校正ツール
- 2 フルーク・ソフトウェア
- 電気試験
- デジタル・マルチメーター
- ベーシック・テスター
- クランプ・メーター
- 電力品質
- 接地
- 設置テスター
- 絶縁ツール
- 本質的安全
- バッテリー・アナライザー
- 絶縁テスター
- ポータブル・オシロスコープ
- 太陽光産業ツール
- 校正ツール
- プロセス校正器
- 電気校正
- RF 校正
- データ収集とテスト装置
- 温度校正
- Humidity calibration
- 圧力校正
- Flow calibration
- Fluke Calibration ソフトウェア
- ツールと計算機
- 空気漏れ計算機 | ROI
- 視野角 (FOV) 計算機
- ii-Series reporting tool
- PT100 calculator
- FCAL PT100 table generator
- Downtime cost calculator
- 熱電対電圧 - 温度コンバータ
- 熱電対タイプ計算機