毎日の生活の質や安全の基礎となる正確な測定は、校正によって確保されています。世界の人々は、あなたが校正の専門家として正しく校正を実施することを期待しています。また、ここには、新しい試験や校正のプロセス、管理の移行、センサーと送信機の校正、現場やベンチでの校正など、さまざまな校正のトピックが掲載された学習用の記事を用意して、正しい校正の実施を支援しています。(当社のフルークの校正のためのブログもご覧ください。)また、お客様が最適な校正器を使用して業務を正しく進めるためのサポートも行っています。当社が推奨するお客様のニーズに合った校正器をご確認ください。温度圧力多機能mA ループベンチトップおよび規格.

校正

校正に関するビデオ

校正に関するオンデマンド・ウェビナー

電力品質

プロセス校正

圧力校正

記事

Calibrating at the bench with a deadweight tester

A deadweight tester is a proven method of pressure calibration that is usually chosen for bench applications when accuracy and reliability are the top requirements. Calibrations are performed at the bench for convenience and to maintain reference conditions.

記事

Hand pumps and pressure test gauges for field pressure testing

It's important to select the proper pump and gauge to match the testing application at hand—a good guideline is the testing device should be 4-10 times more accurate than the device being tested.

記事

Manual approach to pressure switch testing

記事

Calibrating a HART Smart Pressure Transmitter

Verifying and documenting the performance and adjusting a HART smart pressure transmitter can require a bucket full of tools. Performing this task with a HART enabled calibrator like the Fluke 754 simplifies the task and reduces what you need to carry.

ループ校正

記事

新しい制御バルブ・テスト・プロセス

プロセス工業では、スマート比例制御バルブが重要な役割を果たしています。しかし、バルブ性能を正確に評価するには、機器を長時間停止して、バルブをラインから取り外すなどの面倒な作業が伴います。

記事

Breaking new ground without breaking the loop

Early reports from the field suggest that the new Fluke 772 and 773 Milliamp Process Clamp Meters may be game changers, breaking new ground for technicians in the HVAC controls industry. With the feature sets these meters offer, troubleshooting of the most common problems in modern control systems becomes a snap.

記事

How calibration improves optimization

Learn which calibration tools are best for improving optimization and quality in process manufacturing plants including chemical processing, nuclear power, pharmaceutical, pulp and paper.

記事

Troubleshooting 4 to 20 mA Process Control Systems without Breaking the Loop

Troubleshooting 4 to 20 mA (milliamp) process control systems without breaking the loop using Fluke 773 Milliamp Process Clamp Meter

校正に関するすべての記事

記事

Reduce instrument maintenance costs by 40% or more with route-based work flows

記事

Case study: Yuenglings toolbox

What's in your toolbox? Yuengling Tampa Brewery

記事

Case study: Yuengling Brews Up a Winning Maintenance Approach

The Yuengling maintenance team keeps the vintage facility brewing and bottling up to a million barrels of beer yearly. It takes a very lean operation to win against mega-brewers many times Yuengling's size.

記事

How to calibrate a HART Pressure Transmitter from a downloaded task with the Fluke 729

記事

Guide to signal conditioning

Learn signal conditioning basics, types of signal conditioning and how they ensure signal measurement accuracy.

記事

How calibration improves optimization

Learn which calibration tools are best for improving optimization and quality in process manufacturing plants including chemical processing, nuclear power, pharmaceutical, pulp and paper.

記事

Hand pumps and pressure test gauges for field pressure testing

It's important to select the proper pump and gauge to match the testing application at hand—a good guideline is the testing device should be 4-10 times more accurate than the device being tested.

記事

Best accessories to set up a pressure calibration

記事

Assessing control valves and their performance

When assessing control valves and their performance, you need to understand the different types of valves and what they can be tested for.

記事

Why IR accuracy and traceability are critical

Whether you're building automobiles or electronic components, processing food, maintaining electrical systems, or making plastic, temperature inspection using infrared (IR) cameras and spot thermometers is becoming one of the quickest, safest ways to accurately inspect electrical, electronic, mechanical, HVAC, and process control systems.

記事

Why does this year have an extra second?

On December 31, 2016, metrologists around the world—especially those living under Greenwich Mean Time (GMT)— will add a single second to their New Year's Eve countdown.

記事

Glossary of Pressure Calibration Terms

Glossary of Pressure Calibration Terms

記事

Calibrating at the bench with a pressure comparator

A pressure comparator is a convenient instrument for bench pressure calibration. Bench calibrations are performed to maintain reference conditions and to obtain the lowest possible uncertainties. The bench is also a convenient place to inspect, adjust, and repair the devices under test.

記事

Gas custody transfer flow computer calibration

Gas custody transfer flow computers that calculate flow in pipelines by measuring the differential pressure across a flow restriction, such as an orifice plate or other differential pressure flow device, require special calibration to perform at optimum accuracy.

記事

Documenting approach to pressure switch testing

記事

Verifying analog and digital pressure gauges

How to perform a verification test on analog vs digital pressure gauges. Both analog and digital process gauges need to be verified to detect errors related to drift, environment, electrical supply, addition of components to the output loop, and other process changes

記事

How to calibrate a temperature sensor in the field

Pairing a Fluke dry well with a handheld documenting calibrator allows for a complete field temperature sensor calibration solution.

記事

How to keep control valve positioners on target

Learn how to avoid calibration drift on control valve positioners as part of your preventive maintenance program.

記事

Calibrating pressure transmitters and switches in potentially explosive atmospheres

Pressure calibration can be challenging in the best of environments. Working in an area that has the potential for explosion takes the degree of difficulty to another level—one where the technician needs proper training and equipment.

記事

4-20 mA applications by FlukePlus members

Fluke customers share their tool-tips for the 4-20 mA.

記事

NIF Brings Star Power to Earth

You could call this a factory, but you've never seen a plant like this before. The "manufacturing" process here relies on "shots" of laser energy focused on a target the size of a BB. The product: a nuclear reaction six times hotter than the core of the sun . . . and a growing understanding of fusion reactions that could one day free the planet from dependence on dwindling fossil fuels. "

記事

Calibrating at the bench with a deadweight tester

A deadweight tester is a proven method of pressure calibration that is usually chosen for bench applications when accuracy and reliability are the top requirements. Calibrations are performed at the bench for convenience and to maintain reference conditions.

記事

How to overcome pressure leaks during calibration by using the Fluke 729 Automatic Pressure Calibrator

記事

How to Calibrate a Pressure Switch Using the Fluke 729 Automatic Pressure Calibrator

記事

How to Perform a Pressure Calibration Using the Fluke 729

記事

How to perform a pressure leak test using the Fluke 729 Automatic Pressure Calibrator

記事

How to connect a Fluke 729 Automatic Pressure Calibrator to a HART Transmitter

記事

Calibrating a HART Smart Pressure Transmitter

Verifying and documenting the performance and adjusting a HART smart pressure transmitter can require a bucket full of tools. Performing this task with a HART enabled calibrator like the Fluke 754 simplifies the task and reduces what you need to carry.

記事

Manual approach to pressure switch testing

記事

新しい制御バルブ・テスト・プロセス

プロセス工業では、スマート比例制御バルブが重要な役割を果たしています。しかし、バルブ性能を正確に評価するには、機器を長時間停止して、バルブをラインから取り外すなどの面倒な作業が伴います。