Fluke 721 Pressure Calibration Instruments

Model#: Fluke 721-1601
  • Fluke 721 Precision Pressure Calibrator - 1
  • Fluke 721 Precision Pressure Calibrator 2
  • Fluke 721 Precision Pressure Calibrator 3

Fitur utama

  • Precision pressure calibrator with dual isolated sensors for gas flow calibration (custody transfer) applications
  • Features two isolated, stainless steel, pressure sensors with 0.025% accuracy
  • Includes Pt100 RTD input for temperature measurement (probe optional)
  • Measures 4 to 20 mA signals
  • Provides internal 24 V loop power supply to power a transmitter under test

Ikhtisar Produk: Fluke 721 Pressure Calibration Instruments

Fluke 721 Precision Pressure Calibrator provides pressure calibration and temperature measurement for custody transfer applications

The Fluke 721 Precision Pressure Calibrator is the ideal tool for gas custody transfer applications. It features dual isolated pressure sensors to allow you to take simultaneous static and differential pressure measurements with a single tool. And it can be configured by selecting either a 16 psi (1.1 bar) or 36 psi (2.48 bar) low pressure sensor then adding any of seven high pressure ranges: 100, 300, 500, 1000, 1500, 3000 or 5000 psi (6.9, 20, 24.5, 69, 103.4, 200, 345 bar).

Other useful features:

  • Measures up to 30 V DC, checks 24 V loop power supplies
  • Extends pressure measurement range with connection to external 750P
  • 750 series pressure modules (50 ranges)
  • Provides a large backlit graphic display that can show up to three inputs simultaneously
  • Stores five instrument setups for recall

Spesifikasi: Fluke 721 Pressure Calibration Instruments

Spesifikasi 1 Tahun
Fluke-721-1615RentangResolusiAkurasi
Sensor tekanan rendah
-14 psi hingga +16 psi,
-0.97 bar hingga 1,1 bar
0,001 psi,
0,0001 bar
0,025% dari skala penuh
Sensor tekanan tinggi
0 psi hingga +1500 psi,
0,00 bar hingga 103,4 bar
0,1 psi,
0,001 bar
0,025% dari skala penuh
Fluke-721-1630Sensor tekanan rendah
-14 psi hingga +16 psi,
-0.97 bar hingga 1,1 bar
0,001 psi,
0,0001 bar
0,025% dari skala penuh
Sensor tekanan tinggi
0 psi hingga +3000 psi,
0,00 bar hingga 200 bar
0,1 psi,
0,01 bar
0,025% dari skala penuh
Fluke-721-1650Sensor tekanan rendah
-14 psi hingga +16 psi,
-0.97 bar hingga 1,1 bar
0,001 psi,
0,0001 bar
0,025% dari skala penuh
Sensor tekanan tinggi
0 psi hingga +5000 psi,
0,00 bar hingga 345 bar
0,1 psi,
0,01 bar
0,035% dari skala penuh
Fluke-721-3615Sensor tekanan rendah
-14 psi hingga +36 psi,
-0,97 bar hingga 2,48 bar
0,001 psi,
0,0001 bar
0,025% dari skala penuh
Sensor tekanan tinggi
0 psi hingga +1500 psi,
0,00 bar hingga 103,4 bar
0,1 psi,
0,01 bar
0,025% dari skala penuh
Fluke-721-3630Sensor tekanan rendah
-14 psi hingga +36 psi,
-0,97 bar hingga 2,48 bar
0,001 psi,
0,0001 bar
0,025% dari skala penuh
Sensor tekanan tinggi
0 psi hingga +3000 psi,
0,00 bar hingga 200 bar
0,1 psi,
0,01 bar
0,025% dari skala penuh
Fluke-721-3650Sensor tekanan rendah
-14 psi hingga +36 psi,
-0,97 bar hingga 2,48 bar
0,001 psi,
0,0001 bar
0,025% dari skala penuh
Sensor tekanan tinggi
0 psi hingga +5000 psi,
0,00 bar hingga 345 bar
0,1 psi,
0,01 bar
0,035% dari skala penuh
Spesifikasi Umum
Penggunaan kembali pengaturan instrumenTerakhir digunakan saat pengaktifan
LingkunganSuhu pengoperasian -10 °C hingga +50 °C
Suhu penyimpanan (tanpa baterai) -20 °C hingga +60 °C
Ketinggian2.000 m
Perlindungan benda masukIP-40
Kebutuhan daya6,0 V DC
Masa pakai baterai>35 jam, penggunaan tipikal
Baterai diperlukan(4) sel AA standar
Ukuran (P x L x T)7,9 x 4,3 x 2,3 inci (20 x 11 x 5,8 cm)
Bobot0,3539 kg (1 lb 3 oz)
Tekanan konektor/portDua, NPT 1/8 inci, 700P Series Pressure Module; RTD Probe
Pengukuran Kelistrikan dan Suhu 1 Tahun
FungsiRentangResolusiAkurasi
Pengukuran mA0 hingga 24 mA0,001 mA±0,015% dari rdg
±0,002mA
Pengukuran V DC0 hingga 30 V DC0,001 V±0,015% dari rdg
±0,002 V
Ukuran suhu (RTD/ Ohms)1-40 °C hingga 150 °C
(-40 °F hingga 302 °F)
0,01 °C, 0,01 °F±0,015% dari rdg
±0,02 ohms
±0,1 °C (±0,2 °F)
±0,25 °C (±0,45 °F) gabungan ketidakpastian saat menggunakan aksesori probe 720 RTD
Catu daya loop24 VTidak ada24 mA @ 24 V
1. Pengukuran suhu memerlukan probe opsional Fluke-720RTD Pt-100 RTD yang tersedia sebagai aksesori
Dampak Suhu
Tidak terdapat dampak pada akurasi semua fungsi pada suhu 15 °C hingga 35 °C
Tambahkan ±0,002% F.S./°C untuk suhu di luar 15 °C hingga 35 °C
Unit Teknik Tekanan yang Tersedia
psi, bar, mbar, kPa, kgcm2, cmH2O @ 4 °C, cmH2O @ 20 °C, mH2O @ 4 °C, mH2O @ 20 °C, inH2O @ 4 °C, inH2O @ 20 °C, inH2O @ 60 °F, mmHg @ 0 °C, inHg @ 0 °C, ftH2O @ 4 °C, ftH2O @ 20 °C, ftH2O @ 60 °F

Model: Fluke 721 Pressure Calibration Instruments

Fluke 721-1601
Fluke 721-1601 Precision Pressure Calibrator
16 psig, 100 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-1603
Fluke 721-1603 Precision Pressure Calibrator
16 psig, 300 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-1605
Fluke 721-1605 Precision Pressure Calibrator
16 psig, 500 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-1610
Fluke 721-1610 Precision Pressure Calibrator
16 psig, 1000 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke-721-1615
Fluke 721-1615 Precision Pressure Calibrator
16 psig, 1500 psig, dual sensor pressure calibrator

Disertakan dalam paket:

  • Dual Sensor Pressure Calibrator, 16 PSIG, 1500 PSIG
  • Tas pembawa berbahan lembut
  • Empat (4) baterai AA
  • Manual
  • Sertifikat kalibrasi yang dapat dilacak
  • Kabel pengujian
Fluke 721-1630
Fluke 721-1630 Precision Pressure Calibrator
16 psig, 3000 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-1650
Fluke 721-1650 Precision Pressure Calibrator
16 psig, 5000 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3601
Fluke 721-3601 Precision Pressure Calibrator
36 psig, 100 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3603
Fluke 721-3603 Precision Pressure Calibrator
36 psig, 300 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3605
Fluke 721-3605 Precision Pressure Calibrator
36 psig, 500 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3610
Fluke 721-3610 Precision Pressure Calibrator
36 psig, 1000 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3615
Fluke 721-3615 Precision Pressure Calibrator
36 psig, 1500 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3630
Fluke 721-3630 Precision Pressure Calibrator
36 psig, 3000 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Fluke 721-3650
Fluke 721-3650 Precision Pressure Calibrator
36 psig, 5000 psig, dual sensor pressure calibrator

Includes:

  • Soft case
  • Four (4) AA batteries
  • Manual
  • Traceable calibration certificate
  • Test leads
Chat denganasisten Fluke