Finish

Fluke 87V/E2 Combo teollisuuspaketti

  • Fluke 87V / E2 Electrician Combo Kit What’s in the Box
  • Fluke 87V Multimeter
  • Fluke 87V on the Job
  • TPAK Magnetic Hanging Strap

Tärkeimmät ominaisuudet

All functionality of the 87V Industrial Digital Multimeter, plus:

  • Fully insulated 3 mm exposed metal test probes for electricians working in high energy environments
  • C35 Soft Carrying Case holds meter, test leads and other accessories
  • TPAK magnetic hanging strap lets you attach the meter to any ferrous surface, such as cabinets and iron pipes.

Tuotekatsaus: Fluke 87V/E2 Combo teollisuuspaketti

Uusi Combo-paketti perustuu Fluke 87V -mittariin ja sen sisältämien erikoislisävarusteiden ansiosta teollisuuden vianetsintä käy entistä tuottavammaksi. Paketin oston yhteydessä säästät lisävarusteiden hinnassa yli 15 % verrattuna siihen, jos ostaisit lisävarusteet erikseen.

Tekniset tiedot: Fluke 87V/E2 Combo teollisuuspaketti

Specifications
Voltage DCMaximum Voltage1000 V
Accuracy±(0.05% + 1)
Maximum Resolution10 µV
Voltage ACMaximum Voltage1000 V
Accuracy±(0.7% + 2) True RMS
AC Bandwidth20 kHz with low pass filter; 3 db @ 1 kHz
Maximum Resolution0.1 mV
Current DCMaximum Amps10 A (20 A for 30 seconds maximum)
Amps Accuracy±(0.2% + 2)
Maximum Resolution0.01 µA
Current ACMaximum Amps10 A (20 A for 30 seconds maximum)
Amps Accuracy±(1.0% + 2) True RMS
Maximum Resolution0.1 µA
ResistanceMaximum Resistance50 MΩ
Accuracy±(0.2% + 1)
Maximum Resolution0.1Ω
CapacitanceMaximum Capacitance9,999 µF
Accuracy±(1% + 2)
Maximum Resolution0.01 nF
FrequencyMaximum Frequency200 kHz
Accuracy±(0.005% + 1)
Maximum Resolution0.01 Hz
Duty CycleMaximum Duty Cycle99.9%
Accuracy±(0.2% per khz +0.1%)
Maximum Resolution0.1%
Temperature Measurement-200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe
80 BK Temperature Probe-40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greater
ConductanceMaximum Conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum Resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty Cycle RangeAccuracyWithin ±(02% per kHz +0.1%)
Environmental Specifications
Operating Temperature-20°C to +55°C
Storage Temperature-40°C to +60°C
Humidity (Without Condensation)0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)
Operating Altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency ApprovalsUL, CSA, TÜV, VDE listed
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g
624 g - with holster
DisplayDigital6000 counts updates 4/sec.
19,999 counts in high-resolution mode
Analog32 segments, updates 40/sec.
Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery LifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010-1:2001
VibrationPer MIL-PRF-28800 for a Class 2 instrument

Mallit: Fluke 87V/E2 Combo teollisuuspaketti

Fluke 87V/E2 Kit

Yleismittari

Osta

Vakiovarusteet:

  • 87V-yleismittari
  • TL224-silikonimittajohdot
  • suuret AC220-hauenleuat
  • TP238-mittauskärjet
  • magneetti ja hihna
  • 80BK lämpötila-anturi
  • suojakotelo
  • 9 V:n paristo (asennettu valmiiksi)