Fluke 87V Industrial Multimeter
Key features
- Identify complex signal problems fast
- Supports accurate measurements on VFDs using a low-pass filter
- Captures intermittents as fast as 250 µS with Peak Capture
Product overview: Fluke 87V Industrial Multimeter
The Fluke 87V Industrial Multimeter provides the resolution and accuracy to efficiently troubleshoot motor drives, plant automation, power distribution, and electromechanical equipment - even in loud, high-energy, and high-altitude locations. The 87V is designed so you can work more efficiently.
- Easy-access door for fast battery changes without breaking the calibration seal
- Analog bar graph for fast changing or unstable signals
- Large digit display with bright, two-level backlight for easier reading in low light
- Touch Hold keeps readings on display even after removing probes
The 87V lets you identify complex electrical problems fast. It supports accurate measurements on VFDs using a low-pass filter. The meter also captures intermittents as fast as 250 µS using Peak Capture. High-frequency, high-energy noise generated by large drive systems is blocked from your measurements with specially designed shielding.
Built to highest safety standards
All the inputs in the 87V are updated to the third edition of the EN 61010-1 to CAT III 1000 V and CAT IV 600 V. The meter is designed to withstand spikes of more than 8000 V. You also benefit from an audible Input Alert warning if the test leads are placed in the incorrect input jacks for the measurement being made.
Removable holster with built in test lead and probe storage for convenience
The 87V has a removeable holster that also holds a test probe during testing for easier viewing. Relative mode lets you remove test lead resistance, improving accuracy of low-resistance measurements. To make your life even easier, the 87V fits into an optional magnetic hanger for easy set-up and viewing while freeing your hands for other tasks.
Additional measurement features
The Fluke 87V is designed and built in the U.S. and comes with a lifetime warranty.
For a complete comparison of specifications, please visit our selection guide for digital multimeters.
Fluke 87V Industrial Multimeter | Fluke 87V MAX True-rms Digital Multimeter | Fluke 289 True-RMS Data Logging Multimeter | Fluke 179 True-RMS Digital Multimeter | Fluke 1587 FC Insulation Multimeter | |
---|---|---|---|---|---|
CAT rating | CAT III 1000 V CAT IV 600 V | CAT III 1000 V CAT IV 600 V | CAT III 1000 V CAT IV 600 V | CAT III 1000 V CAT IV 600 V | CAT III 1000 V CAT IV 600 V |
True-rms readings | ✔ | ✔ | ✔ | ✔ | ✔ |
Voltage AC/DC | 1000 V | 1000 V | 1000 V | 1000 V | 1000 V |
Current AC/DC | 10 A | 10 A | 10 A | 10 A | 400 mA |
Resistance | 50 MΩ | 50 MΩ | 500 MΩ | 50 MΩ | 50 MΩ |
Capacitance | 9,999 μF | 9,999 μF | 100,000 μF | 9,999 μF | 9,999 μF |
Temperature | -200 °C to 1090 °C | -200 °C to 1090 °C | -200 °C to 1350 °C | -40 °C to 400 °C | -40 °C to 537 °C |
Additional measurement capabilities | Frequency, continuity/diode test, motor drive (VFD) measurement, duty cycle, microamps, analog bar graph, relative reference | Conductance, continuity/diode test, duty cycle, frequency, microamps, motor drive (VFD) measurement, pulse width, elative reference | Conductance (50ns), duty cycle, frequency, continuity/diode test, low input impedance, microamps, pulse width | Continuity/diode test, frequency, microamps | Frequency, Pi/DAR timed ratio tests, continuity/diode test, motor drive (VFD) measurement, microamps, relative reference |
IP rating | IP 30 | IP 67 | IP 42 | - | - |
Battery life | 400 hours | 800 hours | 200 hours | 200 hours | 1000 hours |
Drop test | 3 meters | 4 meters | - | - | - |
Backlit keypad | No | Yes | No | No | No |
What's in the box:
- Fluke 87V Industrial Multimeter
- TL75 Test Leads (TL175 Eur)
- AC175 Alligator Clips
- Holster with tilt-leg, test lead storage
- 80BK Temperature Probe
- 9V Battery (Installed)
Specifications: Fluke 87V Industrial Multimeter
Specifications | ||
Voltage DC | Maximum voltage | 1000 V |
Accuracy | ±(0.05% + 1) | |
Maximum resolution | 10 µV | |
Voltage AC | Maximum voltage | 1000 V |
Accuracy | ±(0.7% + 2) True RMS | |
AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz | |
Maximum resolution | 0.1 mV | |
Current DC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(0.2% + 2) | |
Maximum resolution | 0.01 µA | |
Current AC | Maximum amps | 10 A (20 A for 30 seconds maximum) |
Amps accuracy | ±(1.0% + 2) True RMS | |
Maximum resolution | 0.1 µA | |
Resistance | Maximum resistance | 50 MΩ |
Accuracy | ±(0.2% + 1) | |
Maximum resolution | 0.1 Ω | |
Capacitance | Maximum capacitance | 9,999 µF |
accuracy | ±(1% + 2) | |
Maximum resolution | 0.01 nF | |
Frequency | Maximum frequency | 200 kHz |
Accuracy | ±(0.005% + 1) | |
Maximum resolution | 0.01 Hz | |
Duty cycle | Maximum duty cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) | |
Maximum resolution | 0.1% | |
Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe | |
80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater | |
Conductance | Maximum conductance | 60.00 nS |
Accuracy | ±(1.0% + 10) | |
Maximum resolution | 0.01 nS | |
Diode | Range | 3 V |
Resolution | 1 mV | |
Accuracy | ±(2% + 1) | |
Duty cycle range | Accuracy | Within ±(0.2% per kHz + 0.1%) |
Environmental Specifications | ||
Operating temperature | –20 °C to + 55 °C | |
Storage temperature | –40 °C to + 60 °C | |
Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) | |
Operating Altitude | 2000 m | |
Safety Specifications | ||
Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV | |
Agency approvals | CE, CSA, RCM | |
Mechanical and General Specifications | ||
Size | 201 x 98 x 52 mm (with holster) | |
Weight | 355 g 624 g – with holster | |
Display | Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
Analog | 32 segments, updates 40/sec | |
Frequency | 19,999 counts, updates 3/sec at > 10 Hz | |
Warranty | Lifetime | |
Battery Life | Alkaline | ~400 hours typical, without backlight |
Shock | 1 Meter drop per IEC 61010–1:2001 | |
Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
Models: Fluke 87V Industrial Multimeter
Includes:
- TL75 Test Leads (TL175 EUR)
- AC175 Alligator Clips
- Holster
- 9V Battery (Installed)
- 80BK Temperature Probe
In resistance check mode, what is the maximum output voltage? Is it >8Vdc to test an IGBT gate? Thanks
Does the units come with calibration certs?
which country does fluke 87v origin from?
Are you able to use the Fluke 87-v to check voltage drop?
87V万用表怎么快速有效鉴别进口和国产,真假货怎么判断
I sometimes have to work outside in the winter when temps occasionally drop below zero degrees Fahrenheit. Which multimeters will work in colder temps? Will They be slow?
Manuals + resources: Fluke 87V Industrial Multimeter
- 80 Series V | Users manual
- 80 Series V | Users manual supplement
- 80 Series V | Getting started
- 80 Series V | Getting started supplement
- 80 Series V | Calibration manual
- 80 Series V | Calibration manual supplement
- 80 Series V | Safety sheet
- 80 Series V, 83 V, 85 V, 87 V | Quick reference guide
- 83, 87, 88 Series V | Statement of memory volatility
- 88 V | Quick reference guide