7008/7037/7012/7011 Refrigerated Temperature Calibration Baths

  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getAggregateRating, 67.63ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths
  • 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths
  • 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths

Key features

  • High temperature stability to ±0.0007 °C.
  • Set-point resolution to 0.00003 °C.
  • Exceptional temperature stability (±0.0015 °C) and uniformity (±0.003 °C) at low temperatures down to -40 °C.

Product overview: 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths

These four baths operate at temperatures as low as –40 °C, and each one is built using CFC-free refrigerants. Fluke Calibration’s proprietary controller design and unique tank construction produce bath stabilities to ±0.001 °C or better. These baths are so stable and uniform that national labs use them for comparison calibrations and fixed-point cell maintenance.

Each bath (except the 7011) is fully automatable with a bath interface package and Fluke Calibration’s MET/TEMP II automation software package. When we automate a bath, we automate it completely with computer-controlled solenoid valves for precision balancing of the heating and cooling system. MET/TEMP II performs all calibration tasks automatically, using your PC.

With a Fluke Calibration cold bath, you can forget external coolants. Internal refrigeration systems are all that’s needed to reach each bath’s coldest temperature. Most cold baths may be ordered with an optional pumping lid for supplying external cooling requirements.

Each bath has unique characteristics that make it perfect for specific jobs. Some baths are excellent for SPRTs, some are great with thermistors, and some are perfect for maintaining triple point of water cells. A 7008IR bath can even be used to maintain the temperature of a blackbody cone.

Regardless of your application, Fluke Calibration has a bath that gets the job done, and done better than anyone else can do it. Call us today and tell us about your application.

Specifications: 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths

Specifications
Model7008703770127011
Range–5 °C to 110 °C–40 °C to 110 °C–10 °C to 110 °C
Stability±0.0007 °C at 25 °C (water)
±0.001 °C at 25 °C (mineral oil)
±0.002 °C at –40 °C (ethanol)
±0.0015 °C at 25 °C (water)
±0.003 °C at 100 °C (oil 5012)
±0.0008 °C at 0 °C (ethanol)
±0.0008 °C at 25 °C (water)
±0.003 °C at 100 °C (oil 5012)
Uniformity±0.003 °C at 25 °C (water)
±0.004 °C at 25 °C (mineral oil)
±0.004 °C at –40 °C (ethanol)
±0.002 °C at 25 °C (water)
±0.004 °C at 100 °C (oil 5012)
±0.003 °C at 0 °C (ethanol)
±0.002 °C at 25 °C (water)
±0.004 °C at 100 °C (oil 5012)
Temperature SettingDigital display with push-button data entry
Set-Point Resolution0.002 °C; high-resolution mode, 0.00003 °C0.01 °C; high-resolution mode, 0.00007 °C0.002 °C; high-resolution mode, 0.00003 °C
Display Resolution0.01 °C
Digital Setting Accuracy±1 °C
Digital Setting Repeatability±0.01 °C±0.005 °C
Heaters500 and 1000 Watts
Access Opening (call for customs)324 x 184 mm(12.75 x 7.25 in)162 x 292 mm(6.38 x 11.5 in)127 x 254 mm(5 x 10 in)
Depth331 mm (13 in)457 mm (18 in)305 mm (12 in)
Wetted Parts304 Stainless Steel
Power115 VAC (±10 %), 60 Hz, 14 A or 230 VAC, 50 or 60 Hz, 8 A, specify115 VAC (±10 %), 60 Hz, 16 A or 230 VAC (±10 %), 50 or 60 Hz, 9 A (specify voltage and frequency)115 VAC (±10 %), 60 Hz, 14 A or 230 VAC (±10 %), 50 Hz, 7 A, specify
Volume42 liters (11.2 gal)42 liters (11.2 gal)27 liters (7.2 gal)
Weight61 kg (135 lb)68 kg (150 lb)56.7 kg (125 lb)
Size610 x 775 x 483 mm (24 x 30.5 x 19 in)775 x 768 x 483 mm (30.5 x 30.25 x 19 in)762 x 686 x 401 mm (30 x 27 x 15.8 in)559 x 686 x 401 mm (22 x 27 x 15.8 in)
AutomationUse the 1586A Super-DAQ to automate temperature sensor calibration
 

Models: 7008/7037/7012/7011 Refrigerated Temperature Calibration Baths

7008
Standard Bath, –5 °C to 110 °C, high capacity

Buy it
7011
Standard Bath, –10 °C to 110 °C

Buy it
7012
Standard Bath, –10 °C to 110 °C, deep

Buy it
7037
Standard Bath, –40 °C to 110 °C, deep

Buy it
7008IR
7008 Bath, modified to accept an IR cone

Buy it
2033

IR Cone (NIST design)


Buy it
2016-7008

Fluid Level Adapter, 7008


Buy it
2016-7011

Fluid Level Adapter, 7011


Buy it
2016-7012

Fluid Level Adapter, 7012


Buy it
2016-7037

Fluid Level Adapter, 7037


Buy it
2016-7040

Fluid Level Adapter, 7040


Buy it
2071

Bath Cart, 7011, 7012 (312 mm [12.3 in] H)


Buy it
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getContent, 92.69ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
  • bvseo_sdk, p_sdk, 3.2.1
  • CLOUD, getReviews, 22.6ms
  • REVIEWS, PRODUCT
  • bvseo-msg: HTTP status code of 404 was returned;
Please enable cookies to view product reviews.
Chat with ourFluke assistant
Clear Chat