P5500 Adapters, Separators and Dirt/Moisture Traps
Key features
- P5521 and P5522: liquid-to-liquid separators that prevent calibrator contamination.
- P5531 and P5532: dirt/moisture traps that protect the assembly of a pneumatic deadweight tester.
- P5540, P5541, and P5542: adapter sets for connecting to Fluke P5500 series test pumps.
- P5543 and P5544: adapters for gauge calibration.
- P5551: for removing and refitting pressure gauge pointers.
Product overview: P5500 Adapters, Separators and Dirt/Moisture Traps
Priority Gold Instrument CarePlan
Make sure to ask your account manager about the Fluke Calibration Priority Gold CarePlan
A Fluke Calibration Priority Gold CarePlan puts you in control of your downtime and in control of your business, with calibration services and other offerings.
Deadweight Tester Accessories
Fluke Calibration provides the complete solution for pressure calibration using a deadweight tester, including accessories for test media separation, dirt / moisture traps, dial gauge pointer removers, angle adapters, and two gauge test stands.
P5521 and P5522 Liquid-to-Liquid Separators
These liquid-to-liquid separators connect directly to the test port of a hydraulic deadweight tester or comparison test pump. A flexible diaphragm separates the fluids, protecting the calibrator from contamination, and allows calibration of the device in its specific working fluid.
- P5521-For pressures to 10,000 psi (700 bar)
- P5522-For pressures to 7,000 psi (480 bar) for Skydrol or other aggressive fluids
P5523 Liquid-to-Gas Media Separator
Pressure range 0 to 3,000 psi (210 bar)
For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to-gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pressure gas is balanced against the liquid in a hydraulic deadweight tester through a series of fluid traps.
* Note---since fluid mist may be transferred during operation we do not recommend this device for oxygen safe instruments using an oil operated deadweight tester
P5531 Dirt / Moisture Trap
Pressure range 0 to 500 psi (35 bar)
Dirt / moisture traps provide an effective barrier against the transfer of moisture and dirt from an instrument under test to the sensitive piston/cylinder assembly of a pneumatic deadweight tester. Unexpected particle contamination or fluid inside the device under test will be prevented from entering the deadweight system, avoiding downtime for maintenance or repair. Designed for operation in the vertical position these traps are simple to dismantle and easy to clean.
Designed to mount directly on the deadweight tester and featuring an acrylic chamber for visibility of contaminates this unit utilizes the standard test port adapters for easy instrument connections.
P5532 Dirt / Moisture Trap
Pressure range 0 to 3,000 psi (210 bar)
Dirt / moisture traps provide an effective barrier against the transfer of moisture and dirt from an instrument under test to the sensitive piston/cylinder assembly of a pneumatic deadweight tester. Unexpected particle contamination or fluid inside the device under test will be prevented from entering the deadweight system, avoiding downtime for maintenance or repair. Designed for operation in the vertical position these traps are simple to dismantle and easy to clean.
This high pressure version is provided with an aluminum central chamber for safety and utilizes the standard test port adapters.
P5540, P5541, and P5542 Adapter Sets
These thread adapters come in metric, BSP & NPT sizes to help you make connections with Fluke P5500 series hydraulic and pneumatic comparison test pumps, media separators & accessories.
P5540 Metric
M14 x 1.5, M20 x 1.5, 1/8 and 1/4 BSP
P5541 BSP
1/8, 1/4, 3/8 and 1/2 BSP
P5542 NPT
1/8, 1/4, 3/8 and 1/2 NPT
P5543 Angle Adapter
To calibrate gauges with the pressure connection on the rear (for example, panel mount gauges) in their correct operating position, an angle adaptor should be used. The angle adapter uses the standard gauge adapters and positions the gauges at 90º. The maximum working pressure of this unit is 10,000 psi (700 bar).
P5544 Two Gauge Stand
This adapter mounts directly to the test port of the calibrator and allows for the calibration of two instruments at the same time, or the connection of a reference test instrument. Maximum working pressure is 10,000 psi (700 bar).
P5551 Pointer Remover / Punch
This tool is designed to quickly remove and consistently refit the pointer of a pressure gauge.
Specifications: P5500 Adapters, Separators and Dirt/Moisture Traps
P5521 and P5522 Liquid-to-Liquid Separators
Specifications | |
Pressure Range | P5521: 0 to 10,000 psi (700 bar) P5522: 0 to 7,000 psi (480 bar) for Skydrol and other aggressive fluids |
Instrument Size (W x H) | 4 x 6 in (100 x 150 mm) |
Instrument Weight | 7.5 lb (3.5 kg) |
Test Port Adapter | Uses adapters supplied with calibrator |
Calibrator Connection | 3/8 BSP male (mating adapter supplied) |
Body Material | Aluminum bronze |
Diaphragm | 5521- Viton® 5522-Ethylene Propylene |
Reservoir Material | Hard-anodized aluminum |
P5523 Liquid-to-Gas Media Separator
Specifications | |
Instrument Size (W x D x H) | 17.5 x 12 x 8.5 in ( 440 x 300 x 215 mm) |
Instrument Weight | 24 lb (11 kg) |
Test Port Adapters | 2 sets, 1/8, 1/4, 3/8 and 1/2 NPT or BSP |
Gas Supply Connection | 1/4 NPT female |
P5531 Dirt / Moisture Trap
Specifications | |
Pressure Range | 0 to 500 psi (35 bar) |
Body Material | Stainless steel |
Chamber Material | Acrylic |
O-Rings | Nitrile |
Test Port Connection | As supplied with calibrator |
Deadweight Connection | 3/8 BSP male (mating adapter supplied |
P5532 Dirt / Moisture Trap
Specifications | |
Body Material | Stainless steel |
Chamber Material | Aluminum |
O-Rings | Nitrile |
Test Port Connection | As supplied with calibrator |
Deadweight Connection | 3/8 BSP male (mating adapter supplied) |
P5543 Angle Adapter
Specifications | |
Body materials | Stainless steel |
O-Rings | Nitrile |
Test Port Adapters | As supplied with calibrator |
Calibrator Connection | 3/8 BSP male (mating adapter supplied) |
P5544 Two Gauge Stand
Specifications | |
Body Material | Brass and Stainless steel |
O-Rings | Nitrile |
Test Port Adapters | 1 set, 1/8, 1/4, 3/8 and 1/2 NPT or BSP and adapters supplied with calibrator |
Calibrator Test Connection | 1/2 BSP male (mating adapter supplied) |
Models: P5500 Adapters, Separators and Dirt/Moisture Traps
Pressure Range 0 to 10,000 psi (700 bar)
Pressure Range 0 to 7,000 psi (480 bar)
Pressure range 0 to 3,000 psi (210 bar)
For high pressure pneumatic calibrations this unit interfaces with hydraulic deadweight testers providing a rateless liquid-to-gas separation. Driven by a pneumatic pressure source (nitrogen bottle) and controlled by needle valves, high pressure gas is balanced against the liquid in a hydraulic deadweight tester through a series of fluid traps.
* Note---since fluid mist may be transferred during operation we do not recommend this device for oxygen safe instruments using an oil operated deadweight tester.