Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
Key features
- 0.02% full scale accuracy per 2700G Gauge.
- Adaptors for NPT, BSP, and metric fittings.
- Expandable lower range with additional gauges.
- Battery-operated gauges with line power capability.
Product overview: Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
The Fluke Calibration pneumatic calibrators are an easy-to-use alternative to traditional deadweight testers. These pressure calibrators are conveniently bundled with up to six 2700G Reference Pressure Gauges for a complete, benchtop pressure calibration solution to provide the accuracy, reliability, and capability you need to calibrate dial gauges, digital test gauges and pressure transmitters.
This pneumatic calibrator with a 2700G Reference Pressure Gauge is designed for testing pressure measuring instruments wherever needed, using the included 2700G as the master test gauge. This cost effective instrument is portable, manually operated, requires no external bottle, and provides robust generation of pressure and vacuum up to 300 psi.
- Best-in-class accuracy of 0.02% full scale for each 2700G Reference Gauge
- Expand lower range capability with additional 2700G Reference Gauges
- Adaptors to provide hand tight connection to common NPT, BSP, and metric fitting types
- Included reference gauges are battery operated and capable of using line power too
- Portable with a sturdy carrying case
P5510-2700G specific features:
- Built-in pump for generating both vacuum and positive pressure
- Pressure range 0 to 300 psi 2 MPa (300 psi)
- Vacuum range 0 to 27 inHg (915 mbar)
- Up to three 2700G Reference Pressure gauges
- Fine needle vent valve for small adjustment and venting of pressure
- No external bottle
- Manually operated
P5513-2700G specific features
- Pressure range 0 to 3000 psi (210 bar)
- Vacuum range 0 to 24 inHg (800 mbar)
- Up to three 2700G Reference Pressure gauges
- Built-in screw press for fine pressure adjustments
- Clean testing of process critical instrumentation
- Requires pressure source (i.e. nitrogen bottle) for operation
Specifications: Fluke P5510-2700G, P5513-2700G Pneumatic Pressure Calibrators
Calibrator Model | Range | 1 Year Specification |
P5510-2700G-1 | -12 to 300 psi (-80 kPa to 2 MPa) | Pressure: ±0.06 psi (±0.4 kPa) Vacuum: ±0.15 psi (±1 kPa) |
P5510-2700G-3 | -12 to 300 psi (-80 kPa to 2 MPa) | Pressure: ±0.06 psi (±0.4 kPa) Vacuum: ±0.15 psi (±1 kPa) |
-12 to 100 psi (-80 kPa to 700 kPa) | Pressure: ±0.02 psi (±0.14 kPa) Vacuum: ±0.05 psi (±0.35 kPa) | |
-15 to 15 psi (-100 kPa to 100 kPa) | Pressure: ±0.003 psi (±0.02 kPa) Vacuum: ±0.0075 psi (±0.05 kPa) | |
P5513-2700G-1 | 0 to 3 000 psi (0 to 20 MPa) | Pressure: ±0.6 psi (±0.004 MPa) |
P5513-2700G-3 | 0 to 3 000 psi (0 to 20 MPa) | Pressure: ±0.6 psi (±0.004 MPa) |
-12 to 1 000 psi (-80 Kpa to 7 MPa) | Pressure: ±0.2 psi (±0.0014 MPa) Vacuum: ±0.5 psi (±3.5 kPa) | |
-12 to 1000 psi (-80 kPa to 7 MPa) | Pressure: ±0.02 psi (±0.14 kPa) Vacuum: ±0.05 psi (±0.35 kPa) | |
Media compatibility: Note 1: Any clean, dry non-corrosive gas Note 2: Any liquids or gases compatible with 316 stainless steel Note 3: Any non-flamable, non-toxic, non-explosive, non-oxidizing liquid or gas compatiable with 316 stainless steel | ||
Specifications for P5510-2700G | ||
Pressure Range | 0 to 300 psi (20 bar) | |
Test Port Adapters | (2 sets) 1/8, 1/4, 3/8 and 1/2 NPT or BSP | |
Instrument Size (W x D x H) | 9.5x 13 x 7 in (240 x 330 x 180 mm) | |
Instrument Weight | 7.5 lb (3.5 kg) | |
Vacuum Range | 0 to 24 inHg (800 mbar) | |
Specifications for P5513-2700G | ||
Pressure Range | 0 to 3000 psi (210 bar) | |
Test Port Adapters | (2 sets) 1/8, 1/4, 3/8 and 1/2 NPT or BSP | |
Instrument Size (W x D x H) | 17.5 x 12 x 8.5 in (440 x 300 x 215 mm) | |
Instrument weight | 17 lb (8 kg) | |
Gas Supply Connection | 1/4 NPT female |