Fluke i3000 Flex AC Current Clamp, 4 Pack
Model#: Fluke i3000 Flex 4PK
Key features
- Three ranges
- 30 A
 - 300 A
 - 3000 A, 1, 10 or 100 mV/A output
 
 - Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
 - Maximum conductor diameter 178 mm (7 in)
 - CAT III 600 V safety rating
 
Product overview: Fluke i3000 Flex AC Current Clamp, 4 Pack
The i3000s Flex is an AC current clamp utilizing the Rogowski principle. It can be used to measure currents up to 3000 A when used in conjunction with oscilloscopes, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
Specifications: Fluke i3000 Flex AC Current Clamp, 4 Pack
| Electrical Specifications | |
| Current ranges | 30 A | 
| 300 A | |
| 3000 A | |
| AC rms | |
| Output sensitivity (AC-coupled) | 100 mV | 
| 10 m | |
| 1 mV per A | |
| Load impedance | 100 kΩ minimum | 
| Accuracy | at +25°C | 
| ±1% of range (45 Hz to 65 Hz) | |
| Linearity | 10% to 100% of range | 
| ±0.2% of reading | |
| Noise | 8 mV AC rms (30 A) | 
| 2 mV AC rms (300 A, 3000 A) | |
| Frequency range | 10 Hz to 50 kHz (-3 dB) | 
| Phase error | < ±1° (45 Hz to 65 Hz) | 
| ±10° (at 20 kHz) | |
| Position sensitivity (with cable > 25 mm from the coupling) | 
 Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.  | 
| ±2% of range | |
| External field | with cable > 200 mm from the head | 
| ±1% of range | |
| Power supply | 2 x AA/MN 1500/LR6 Alkaline, 400 hours, low battery indicator | 
| Temperature coefficient | ±0.08% of reading per °C | 
| Working voltage | see safety standards section | 
| 600 V AC rms or DC | |
| General Specifications | |
| Head circumference | 610 mm (24in) | 
| Head cable diameter | 14.3 mm (0.56in) | 
| Head bend radius | 38.1 mm (1.5in) | 
| Cable length (head to electronics) | 2 m (6.56 ft) | 
| Output connection | 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter | 
| Operating temperature range | -20°C to +90°C (-4°F to 190°F) (head) | 
| -20°C to +85°C (-4°F to 185°F) (electronics) | |
| Strong temperature range | -40°C to +105°C (-40°F to 221°F) (head) | 
| -20°C to +85°C (-4°F to 185°F) (electronics) | |
| Operating humidity | 15% to 85% (non-condensing) | 
| Weight | 180 g (0.396 lb) (head) | 
| 190 g (0.419 lb) (electronics) | |
| Safety standards | BS EN 61010-1: 2001 | 
| BS EN 61010-2-032: 2002 | |
| BS EN 61010-031: 2002 | |
| 600 Vrms, Category III, Pollution Degree 2 | |
| Use of the probe on uninsulated conductors is limited to 600 V AC rms or DC and frequencies below 1 kHz | |
| EMC standards | EN 61326: 1998 +A1, A2, and A3 | 
| Head cable length (double insulated) | 610 mm or 914 mm, depending on model | 
Models: Fluke i3000 Flex AC Current Clamp, 4 Pack
Fluke i3000 Flex 4PK